McMaster-Carr logo
    Filter by
    Electrical Phase
    Number of Wires
    For Number of Fuses
    Number of Circuits Controlled
    Actuator Color
    For Wire Gauge
    Fuse UL Class
    Housing Color
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Switch Action
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    74 Products

    Durable Disconnect Switches

    Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Durable Disconnect Switches.
    Fuse Holder—Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs. Met
    Each
    Each
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Viewing Window
    30600V AC/600V DC3PST
    Single (10 hp @ 600V AC)
    Three (30 hp @ 600V AC)
    314 5/8"7 9/16"3/8"TabNEMA 1
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K780000000———0
    60600V AC/600V DC3PST
    Single (30 hp @ 600V AC)
    Three (60 hp @ 600V AC)
    318 1/8"9"3/8"TabNEMA 1
    UL Listed, CSA Certified
    7499K79000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)3RK1, RK5, J, K5, H14 5/8"7 9/16"3/8"TabNEMA 1
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K580000007499K111000000
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)4RK1, RK5, J, K5, H14 5/8"7 9/16"3/8"TabNEMA 1
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K730000007499K11100000
    60600V AC/600V DC3PST
    Three (50 hp @ 600V AC)3RK1, RK5, J, K5, H18 1/8"9"3/8"TabNEMA 1
    UL Listed, CSA Certified
    7499K570000007499K11200000
    60600V AC/600V DC3PST
    Three (50 hp @ 600V AC)4RK1, RK5, J, K5, H18 1/8"9"3/8"TabNEMA 1
    UL Listed, CSA Certified
    7499K590000007499K11200000
    100600V AC/600V DC3PST
    Three (100 hp @ 600V AC)4RK1, RK5, J, K5, H21 7/8"9"3/8"TabNEMA 1
    UL Listed, CSA Certified
    7499K670000007499K11300000
    200600V AC/600V DC3PST
    Three (150 hp @ 600V AC)4RK1, RK5, J, K5, H29"17"3/8"TabNEMA 1
    UL Listed, CSA Certified
    7499K69000000007499K11400000
     

    Outdoor Durable Disconnect Switches

    All switches have quick-make/quick-break action to eliminate arcing and prolong switch life.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Outdoor Durable Disconnect Switches.
    Enamel-Coated Steel Housing—The enclosure is steel, so it withstands tougher conditions than plastic enclosures.
    Fuse Holder—Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    Lockout—They have a lockout to secure in the off position using a padlock (not included).
    NEMA 3R Enclosure Rating—A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse
    UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs. Met
    Each
    Each
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Viewing Window
    30600V AC/600V DC3PST
    Single (10 hp @ 240V AC)
    Three (30 hp @ 600V AC)
    315"7 3/4"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K910000000———0
    60600V AC/600V DC3PST
    Single (30 hp @ 240V AC)
    Three (60 hp @ 600V AC)
    318 1/2"9 1/16"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K83000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)3RK1, RK5, J, H15"7 3/4"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K760000007499K111000000
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)4RK1, RK5, J, H15"7 3/4"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K930000007499K11100000
    60600V AC/600V DC3PST
    Three (50 hp @ 600V AC)3RK1, RK5, J, H17 1/2"10 1/2"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K680000007499K11200000
    60600V AC/600V DC3PST
    Three (50 hp @ 600V AC)4RK1, RK5, J, H18 1/2"9 1/16"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K740000007499K11200000
    100600V AC/600V DC3PST
    Three (100 hp @ 600V AC)4RK1, RK5, J, H22 1/8"9 1/16"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K75000000007499K11300000
    200600V AC/600V DC3PST
    Three (150 hp @ 600V AC)4RK1, RK5, J, H29"17"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K77000000007499K11400000
     

    Enclosed Compact Disconnect Switches

    Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Enclosed Compact Disconnect Switches.
    Plastic Housing—Their plastic housing protects the switch and resists denting, chipping, and cracking.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—Rated IP65, the housing also seals out water even in frequently washed down areas.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K210000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K22000000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K23000000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K24000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K25000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K26000000
     
    4 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K34000000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K35000000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K36000000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K37000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K38000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K39000000
     

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    25600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N110000000
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    32600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N12000000
    3Single (3 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    40600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N13000000
    3Three (10 hp @ 240V AC)
    Three (20 hp @ 480V AC)
    3 Off
    3PST-NO
    63600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N14000000
    3Three (15 hp @ 240V AC)
    Three (30 hp @ 480V AC)
    3 Off
    3PST-NO
    80600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N15000000
    3Three (25 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    125600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N16000000
    3Three (30 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    175600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N17000000
     

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     
    Gray Powder-Coated Aluminum Housing with Yellow Actuator
     
    3 Circuits Controlled with Lockout
    B606003PST
    Three (40 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1200000000
    B1006003PST
    Three (50 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1300000000
     

    Enclosure Disconnect Switches

    Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Switches with Lockout and Fuse Holder
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout and Fuse Holder.
    Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse's rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire.
    Mounting Depth—Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Enclosure Rating—All meet at least one safety standard.
    Switches
    Replacement
    Shafts
    Replacement
    Shaft Bases
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    For No.
    of Fuses
    For Fuse
    UL Class
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure
    Rating
    Each
    Each
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled—For 1 15/32" Dia. Panel Cutouts
    30600Single (Not Rated)
    Three (7 1/2 hp @ 240V AC)
    Three (20 hp @ 600V AC)
    3J5 11/32"5 7/8"357 7/8" to 20 9/16"IP20
    7277K30100000007277K2060000007277K207000000
    60600Single (Not Rated)
    Three (15 hp @ 240V AC)
    Three (50 hp @ 600V AC)
    3J5 11/32"5 7/8"357 7/8" to 20 9/16"IP20
    7277K3030000007277K206000007277K20700000
    100600Single (Not Rated)
    Three (30 hp @ 240V AC)
    Three (75 hp @ 600V AC)
    3J7 5/16"5 15/16"357 7/8" to 20 9/16"IP20
    7277K3050000007277K206000007277K20700000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 1 15/32" Dia. Panel Cutouts
    30600Single (Not Rated)
    Three (7 1/2 hp @ 240V AC)
    Three (20 hp @ 600V AC)
    3J5 11/32"5 7/8"357 7/8" to 20 9/16"IP20
    7277K3020000007277K206000007277K20700000
    60600Single (Not Rated)
    Three (15 hp @ 240V AC)
    Three (50 hp @ 600V AC)
    3J5 11/32"5 7/8"357 7/8" to 20 9/16"IP20
    7277K3040000007277K206000007277K20700000
    100600Single (Not Rated)
    Three (30 hp @ 240V AC)
    Three (75 hp @ 600V AC)
    3J7 5/16"5 15/16"357 7/8" to 20 9/16"IP20
    7277K3060000007277K206000007277K20700000
     
    Accessories and Replacements for Disconnect Switches

    Undervoltage Disconnect Switches

    Prevent motors and other equipment from overheating or failing from not having enough voltage. When the supply voltage falls below 35% of the rated voltage, these switches will automatically turn off to protect the circuit from undervoltage. Once the power is cut, they'll keep it isolated to prevent accidental startups during inspection and maintenance.
    To prevent unauthorized use of these switches, you can lock them out with a padlock (not included). Even if a padlock blocks them from physically turning off, they’ll disconnect power to the actuator if voltage falls below a safe level.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Undervoltage Disconnect Switches.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Black Actuator
     
    2 Circuits Controlled with Lockout—For 1/2" Dia. Panel Cutouts
    40230Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"3 1/8"5/16"Screw TerminalIP54
    UL Listed, C-UL Listed, CSA Certified
    7772N120000000
     
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 1/2" Dia. Panel Cutouts
    40230Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"3 1/8"5/16"Screw TerminalIP54
    UL Listed, C-UL Listed, CSA Certified
    7772N11000000
     

    Frame-Mounted Safety Switches

    Image of ProductInUse. Key Shown Actuating from the Side. Front orientation. Safety Switches. Frame-Mounted Safety Switches.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style C.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style D.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style F.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style G.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style H.

    Key Shown Actuating from the Side

    Style C

    Style D

    Style F

    Style G

    Style H

    Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
    Styles C-G—Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
    IP67 Enclosure Rating—IP67 rated switches protect against temporary submersion.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches protect against washdowns.
    Key Included—All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key.
    Housing
    Conduit
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Ht.
    Wd.
    Dp.
    Trade
    Size
    Thread
    Size
    Thread
    Type
    Key
    Included
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts
    C21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    10 amp @ 120V AC, 2 amp @ 24V DC250V AC
    24V DC
    3.6"2.1"1.3"1/2
    NPT
    YesIP65, NEMA 4
    65665K130000000
    C31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    4 amp @ 230V AC, 4 amp @ 24V DC500V AC
    24V DC
    3.5"2"1.2"M16
    Metric
    YesIP67
    65665K18000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"M20
    Metric
    NoIP67
    65665K112000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    BSPP
    NoIP67
    65665K111000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    NPT
    NoIP67
    65665K105000000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"M20
    Metric
    NoIP67
    65665K11300000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    BSPP
    NoIP67
    65665K10800000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    NPT
    NoIP67
    65665K109000000
     
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts and Rotating Head
    D31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC240V AC
    250V DC
    3.8"1.2"1.2"M20
    Metric
    NoIP67
    65665K2900000
    G31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    10 amp @ 230V AC, 4 amp @ 24V DC250V AC
    24V DC
    4.3"1.6"1.4"M20
    Metric
    NoIP67
    65665K19000000
     
    Screw-Terminal Wire Connection with Rotating Head
    H42 Off and 2 On
    Maintained
    84PST-2NO/2NC
    2.5 amp @ 120V AC, 1 amp @ 125V DC120V AC
    125V DC
    7.1"1.5"1.5"1/2
    NPT
    NoIP67
    65665K31000000
     
    Actuator Keys
    back to top