    Manual Override Enclosure Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Manual Override Enclosure Disconnect Switches.

    Power Pole

    Neutral Pole

    Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. Cut the shaft to fit your enclosure.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    Safety Interlock—When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure Rating
    Certification
    Each
    Black Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N170000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N18000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N19000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N21000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N22000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N23000000
     
    Black Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N11000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N12000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N13000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N14000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N15000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N16000000
     
    Accessories and Replacements for Disconnect Switches

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     
    Gray Powder-Coated Aluminum Housing with Yellow Actuator
     
    3 Circuits Controlled with Lockout
    B606003PST
    Three (40 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1200000000
    B1006003PST
    Three (50 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1300000000
     
    back to top