Choosing an Electrical Switch
More
Harsh Environment Panel-Mount Disconnect Switches



Rated IP69K, these switches withstand high-pressure, high-temperature washdowns. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included).
Switching | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Dia. | Ht. | Wd. | Dp. Behind Panel | Each | ||
Yellow Stainless Steel Housing with Red Actuator | |||||||||||
2 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
A | 20 | 300V AC | Stays Switched (Maintained) | DPST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 3 15/16" | __ | __ | 2 15/16" | 00000000 | 0000000 |
3 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
B | 40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
B | 60 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
4 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
A | 20 | 300V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 3 15/16" | __ | __ | 3 3/8" | 00000000 | 000000 |
Gray Stainless Steel Housing with Gray Actuator | |||||||||||
2 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
C | 20 | 300V AC | Stays Switched (Maintained) | DPST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | __ | 3 1/8" | 2 3/4" | 2 15/16" | 00000000 | 000000 |
3 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
B | 40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
B | 60 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
4 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
C | 20 | 300V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | __ | 3 1/8" | 2 3/4" | 3 3/8" | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Frame-Mounted RFID Safety Switches

Prevent accidental bumps or vibration from triggering these safety switches unnecessarily—a strong magnet maintains the RFID signal between the actuator and switch until it's intentionally opened. Also known as interlock switches, they automatically cut power when you open an access door, interrupting the signal, then restore power when the door is closed, and the switch and actuator meet. They're designed to mount on a frame and a door, gate, or window. Use them in many ways—from turning off a machine-operated saw when you open the protective window to powering down robotic arms when someone enters the partitioned area. The LED indicator shows that your switch is on and whether it’s actuated.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a unique RFID code are only compatible with their own actuator, so they’re difficult to tamper with.
IP69K rated switches protect against high-pressure, high-temperature washdowns.

Housing | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | No. of Wire Leads | Cable Lead Lg. | Ht. | Wd. | Dp. | Mounting Fasteners Included | Features | Environmental Rating | Each | |
Stainless Steel Housing | |||||||||||||||
With Wire Leads | |||||||||||||||
1 | 101 | 10 | 24V DC | 200mA | PNP | 8 | 16ft. | 3.8" | 2.5" | 1.5" | Yes | Auxiliary PNP Output, LED Status Indicator, Magnetic Latch, Unique RFID Code | IP69K | 0000000 | 0000000 |
RFID Safety Switches

The convenient, modern alternative to mechanical safety switches. These RFID switches are easier to install, fit a wider range of access points, and can mount horizontally. Since they don't need a traditional key to actuate, they work even if the switch and actuator are slightly misaligned. Also known as interlock switches, they shut off power to equipment as soon as you open the barrier, which disconnects the RFID signal. These switches are often used with small machines. Find them anywhere from a CNC machine’s window to a packaging machine’s service panel. Mount the switch on the frame and the actuator on the barrier. Rated IP67 and IP69K, these switches are protected against temporary submersion and high-pressure, high-temperature washdowns.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a magnetic latch help prevent a barrier from opening by accident, such as from light bumps and low vibrations. The magnet keeps the actuator and switch from separating.
Micro M12 cords (sold separately) connect switches to your system’s circuits.


Switches | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Mounting | Replacement Actuators | ||||||||||||||||
No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Slots | Slot Lg. | Slot Wd. | Features | Environmental Rating | Each | Each | ||
Plastic Housing | ||||||||||||||||||
With 8-Pole Micro M12 Plug | ||||||||||||||||||
1 | __ | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output | IP65, IP67, IP69K | 00000000 | 0000000 | 0000000 | 000000 |
1 | 4 | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Magnetic Latch | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |

Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Voltage | Current | Wire Gauge | OD | Insulation Material | Environmental Rating | Each | |
8 | A | 0.3" | 3 | 30V AC/30V DC | 2A | 22 | 0.22" | PVC Plastic | IP66K, IP67 | 0000000 | 0000000 |
Tamper-Resistant RFID Safety Switches

Block access to machinery while it's running. These safety switches cut power when their signal disconnects, shutting off equipment as you open machine guards. They link to a single actuator, so no other RFID tag or card can interfere. The unique RFID code means that once the power is cut, no one can bypass the switch and restart equipment while the guard is open.
These switches are often used with small machines where there’s no risk of the barrier closing on its own. Find them anywhere from a CNC machine’s window to a machine-operated saw’s service panel. Mount the switch on the frame and the actuator on the barrier. They're also known as interlock switches. Rated IP67 and IP69K, these switches are protected against temporary submersion and high-pressure, high-temperature washdowns.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a magnetic latch prevent guards from opening by accident, such as from light bumps and low vibrations.
Micro M12 cords (sold separately) connect switches to your system’s circuits.


Switches | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Mounting | Replacement Actuators | ||||||||||||||||
No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Slots | Slot Lg. | Slot Wd. | Features | Environmental Rating | Each | Each | ||
Plastic Housing | ||||||||||||||||||
With 8-Pole Micro M12 Plug | ||||||||||||||||||
1 | __ | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Unique RFID Code | IP65, IP67, IP69K | 00000000 | 0000000 | 0000000 | 000000 |
1 | 4 | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Magnetic Latch, Unique RFID Code | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |

Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Voltage | Current | Wire Gauge | OD | Insulation Material | Environmental Rating | Each | |
8 | A | 0.3" | 3 | 30V AC/30V DC | 2A | 22 | 0.22" | PVC Plastic | IP66K, IP67 | 0000000 | 0000000 |