Filter by
Switching Voltage
Maximum Padlock Shackle Diameter
Horsepower @ Switching Voltage
Actuator Color
Switch Action
Switch Type
DFARS Specialty Metals
Export Control Classification Number (ECCN)
REACH
RoHS
UL File Number
Specifications Met
Certification
Housing Material
Housing Color
Wire Connection
Electrical Connection
Choosing an Electrical Switch
More
DIN-Rail Mount Disconnect Switches
Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
Switches

Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | For Max. Padlock Shackle Dia. | For DIN Rail Ht., mm | Wire Connection Type | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||||||
3 Circuits with Lockout | ||||||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
50 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 3/8" | 2 1/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
63 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 3 3/8" | 2 1/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
80 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 2 7/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
100 | 600V AC | Stays Switched (Maintained) | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 2 7/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
4 Circuits with Lockout | ||||||||||||
25 | 600V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
32 | 600V AC | Stays Switched (Maintained) | 4PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
50 | 600V AC | Stays Switched (Maintained) | 4PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 3/8" | 2 1/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
63 | 600V AC | Stays Switched (Maintained) | 4PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 3 3/8" | 2 1/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
80 | 600V AC | Stays Switched (Maintained) | 4PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 2 7/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
100 | 600V AC | Stays Switched (Maintained) | 4PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 2 7/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
Auxiliary Contact Blocks

Switching Current, A | Each | |
10 | 0000000 | 000000 |
Terminal Covers