McMaster-Carr logo
    Filter by
    Switching Voltage
    Industrial Info Snippet
    Electrical Phase
    Enclosure Rating
    Industrial Info Compare
    Environment
    For Number of Fuses
    Width
    Number of Wires
    Fuse UL Class
    Horsepower @ Switching Voltage
    Number of Circuits Controlled
    Height
    Actuator Color
    Knockout Trade Size
    Industrial Info Compare
    Housing Material
    Electrical Connection
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Housing Finish
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    3 Products

    Durable Disconnect Switches

    Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Durable Disconnect Switches.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    Fuse Holder—Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Each
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    200600V AC/600V DC3PST
    Three (150 hp @ 600V AC)4RK1, RK5, J, K5, H29"17"3/8"TabNEMA 1
    UL Listed, CSA Certified
    7499K690000000007499K114000000
     

    Outdoor Durable Disconnect Switches

    All switches have quick-make/quick-break action to eliminate arcing and prolong switch life.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Outdoor Durable Disconnect Switches.
    Enamel-Coated Steel Housing—The enclosure is steel, so it withstands tougher conditions than plastic enclosures.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    Fuse Holder—Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Lockout—They have a lockout to secure in the off position using a padlock (not included).
    NEMA 3R Enclosure Rating—A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse
    UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Each
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    200600V AC/600V DC3PST
    Three (150 hp @ 600V AC)4RK1, RK5, J, H29"17"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K770000000007499K114000000
     
    back to top