    Durable Disconnect Switches

    Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Durable Disconnect Switches.
    Fuse Holder—Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs. Met
    Each
    Each
    Gray Enamel-Coated Steel Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock
    30600V AC/600V DC3PDT
    Single (5 hp @ 240V AC)
    Single (7 1/2 hp @ 480V AC)
    Single (10 hp @ 600V AC)
    329 15/16"12"3/8"Tab TerminalNEMA 1
    UL Listed
    1960N40000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    30600V AC/600V DC3PDT
    Single (3 hp @ 480V AC)
    Three (5 hp @ 480V AC)
    Three (7 1/2 hp @ 600V AC)
    3RK1, RK5, J, K5, H38 7/16"12"3/8"Tab TerminalNEMA 1
    UL Listed
    1960N100000000———0
     
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Viewing Window
    30600V AC/600V DC3PST
    Single (10 hp @ 600V AC)
    Three (30 hp @ 600V AC)
    314 5/8"7 9/16"3/8"Tab TerminalNEMA 1
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K78000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)3RK1, RK5, J, K5, H14 5/8"7 9/16"3/8"Tab TerminalNEMA 1
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K580000007499K111000000
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)4RK1, RK5, J, K5, H14 5/8"7 9/16"3/8"Tab TerminalNEMA 1
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K730000007499K11100000
     
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3RK1, RK5, K5, H14 1/4"6 5/8"5/16"Tab TerminalNEMA 1
    UL Listed
    7524K210000007524K41400000
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    30240V AC/250V DC3PST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3RK1, RK5, K5, H14 1/4"6 5/8"5/16"Tab TerminalNEMA 1
    UL Listed
    7524K110000007524K41400000
     
    3 Circuits Controlled with Lockout
    30240V AC/250V DC3PST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    36 3/8"4 9/16"5/16"Tab TerminalNEMA 1
    UL Listed
    7524K3100000———0
     

    Outdoor Durable Disconnect Switches

    All switches have quick-make/quick-break action to eliminate arcing and prolong switch life.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Outdoor Durable Disconnect Switches.
    Enamel-Coated Steel Housing and Powder-Coated Steel Housing—The enclosure is steel, so it withstands tougher conditions than plastic enclosures.
    Fuse Holder—Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    Lockout—They have a lockout to secure in the off position using a padlock (not included).
    NEMA 3R Enclosure Rating—A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse
    UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs. Met
    Each
    Each
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Viewing Window
    30600V AC/600V DC3PST
    Single (10 hp @ 240V AC)
    Three (30 hp @ 600V AC)
    315"7 3/4"3/8"Tab TerminalNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K910000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)3RK1, RK5, J, H15"7 3/4"3/8"Tab TerminalNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K760000007499K111000000
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)4RK1, RK5, J, H15"7 3/4"3/8"Tab TerminalNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K930000007499K11100000
     
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)3RK1, RK5, K5, H8 9/16"5 7/16"5/16"Tab TerminalNEMA 3R
    UL Listed
    7524K24000007524K411000000
     
    3 Circuits Controlled with Lockout and Fuse Holder
    30240V AC/250V DC3PST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4RK1, RK5, K5, H8 9/16"5 7/16"5/16"Tab TerminalNEMA 3R
    UL Listed
    7524K140000007524K411000000
     
    3 Circuits Controlled with Lockout
    30240V AC/250V DC3PST
    Three (7 1/2 hp @ 240V AC)36 3/8"4 9/16"5/16"Tab TerminalNEMA 3R
    UL Listed
    7524K34000000———0
     

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.

    Style A

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.

    Style A

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     

    Washdown Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Switch with Lockout and Stainless Steel Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Stainless Steel Housing, 3 Circuits Controlled with Lockout.

    Switch with Lockout

    and Stainless Steel

    Housing

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    IP66 Enclosure Rating—The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Stainless Steel Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    306003PST
    Single (1 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K610000000
     
    Accessories for Disconnect Switches

    Enclosure Disconnect Switches

    Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Switches with Lockout and Fuse Holder
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout and Fuse Holder.
    Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse's rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire.
    Mounting Depth—Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Enclosure Rating—All meet at least one safety standard.
    Switches
    Replacement
    Shafts
    Replacement
    Shaft Bases
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    For No.
    of Fuses
    For Fuse
    UL Class
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure
    Rating
    Each
    Each
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled—For 1 15/32" Dia. Panel Cutouts
    30600Single (Not Rated)
    Three (7 1/2 hp @ 240V AC)
    Three (20 hp @ 600V AC)
    3J5 11/32"5 7/8"357 7/8" to 20 9/16"IP20
    7277K30100000007277K2060000007277K207000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 1 15/32" Dia. Panel Cutouts
    30600Single (Not Rated)
    Three (7 1/2 hp @ 240V AC)
    Three (20 hp @ 600V AC)
    3J5 11/32"5 7/8"357 7/8" to 20 9/16"IP20
    7277K3020000007277K206000007277K20700000
     
    Accessories and Replacements for Disconnect Switches

    Manual Transfer Switches

    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1.

    NEMA 1

    If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
    Use them with a portable generator.
    NEMA 1—NEMA 1 switches should be used indoors.
    Housing
    Mounting
    Max. Power,
    W
    Switching Current
    (No. of Switches)
    Circuit Breaker Breakthrough
    Current, amp
    Electrical
    Phase
    Housing Material
    Ht.
    Wd.
    Dp.
    Generator Connection
    NEMA Type
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Certification
    Specs. Met
    Each
    NEMA 1
     
    10 Circuits Controlled
    7,50030 amp @ 240V AC (1 DPDT)
    20 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N180000000
     