McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    39 Products

    Panel-Mount Compact Disconnect Switches

    Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Compact Disconnect Switches.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—They’re rated IP65 for protection from washdowns.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1060000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K113000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K16000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K46000000
     

    Enclosed Compact Disconnect Switches

    Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Enclosed Compact Disconnect Switches.
    Plastic Housing—Their plastic housing protects the switch and resists denting, chipping, and cracking.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—Rated IP65, the housing also seals out water even in frequently washed down areas.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K260000000
     
    4 Circuits Controlled with Lockout
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K39000000
     

    Panel-Mount Disconnect Switches

    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Disconnect Switches.
    Image of Product. Power Pole. Front orientation. Disconnect Switches. Panel-Mount Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Panel-Mount Disconnect Switches.

    Power Pole

    Neutral Pole

    Install these switches in a panel cutout. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Switch with Lockout. Front orientation. Disconnect Switches. Panel-Mount Disconnect Switches, Plastic Housing, Lockout, 3 Circuits Controlled.

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Certification—All are UL listed, C-UL listed, and CE marked—they meet American, Canadian, and European safety standards.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled—For 3/8" Dia. Panel Cutouts
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"3 3/4"2 11/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K2450000000
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"2 11/16"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K225000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 3/8" Dia. Panel Cutouts
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"3 3/4"2 11/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K235000000
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"2 11/16"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K215000000
     
    Accessories and Replacements for Disconnect Switches

    Washdown Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Switch with Plastic Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Plastic Housing.
    Image of Product. Switch with Lockout and Plastic Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled with Lockout.
    Image of Product. Switch with Lockout and Stainless Steel Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Stainless Steel Housing, 3 Circuits Controlled with Lockout.

    Switch with

    Plastic Housing

    Switch with

    Lockout and

    Plastic Housing

    Switch with Lockout

    and Stainless Steel

    Housing

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    IP66 Enclosure Rating—The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    11"7 1/2"3/8"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K140000000
     
    Stainless Steel Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K64000000
     
    Accessories for Disconnect Switches

    Enclosure Disconnect Switches

    Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Switches with Lockout Only
    Image of Product. 3 Circuits. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout Only, Plastic Housing, 3 Circuits Controlled.
    Image of Product. 4 Circuits. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout Only, Plastic Housing, 4 Circuits Controlled.
    Image of Product. Front orientation. Switch Seals. Enclosure Disconnect Switches.

    3 Circuits

    4 Circuits

    Sealing Gaskets

    Mounting Depth—Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Enclosure Rating—All meet at least one safety standard.
    Sealing Gaskets—Use sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
    Switches
    Replacement
    Shafts
    Replacement
    Shaft Bases
    Sealing Gaskets
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure
    Rating
    Each
    Each
    Each
    Each
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K3100000007277K160000007277K17000007277K1900000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K550000007277K16000007277K1700007277K190000
     
    4 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K370000007277K16000007277K1700007277K190000
     
    Accessories and Replacements for Disconnect Switches

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Three (15 hp @ 240V AC)
    Three (30 hp @ 480V AC)
    3 Off
    3PST-NO
    80600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N150000000
     

    Manual Override Enclosure Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Manual Override Enclosure Disconnect Switches.

    Power Pole

    Neutral Pole

    Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. Cut the shaft to fit your enclosure.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    Safety Interlock—When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure Rating
    Certification
    Each
    Black Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N220000000
     
    Black Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N15000000
     
    Accessories and Replacements for Disconnect Switches

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Three-Circuit Switch. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled.
    Image of Product. Three-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled with Lockout.

    Three-Circuit

    Switch

    Three-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K3150000000
     
    3 Circuits Controlled
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K335000000
     
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled with Lockout
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K325000000
     
    3 Circuits Controlled
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K345000000
     
    Accessories and Replacements for Disconnect Switches

    DIN-Rail Mount Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.

    Power Pole

    Neutral Pole

    Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
    Use additional power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Maintained SwitchAbout Maintained Switch
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N150000000
     
    4 Circuits Controlled with Lockout
    806004PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N22000000
     
    Accessories for Disconnect Switches
    back to top