McMaster-Carr logo
    Filter by
    Power Source
    Intake Tube Material
    Discharge Pipe Size
    Industrial Info Compare
    Maximum Pressure
    Discharge Connection
    For Drum Opening Pipe Size
    Industrial Info Compare
    Discharge Tube ID
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    66 Products

    Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional2.2 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K43000000
     
    24V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional1.4 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K4400000
     

    Adjustable-Flow Easy-Stroke Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Easy-Stroke Drum Pumps for Water and Chemicals, 304 Stainless Steel Housing.

    304 Stainless

    Steel Housing

    These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
    Whenever working with flammable liquids, always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.
    Intake
    Flow Rate, fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    For Discharge
    Tube ID
    Spout
    Type
    Each
    304 Stainless Steel Intake Tube and 304 Stainless Steel Housing
    6, 8, 10, 1215 to 552,000Not Rated1401 1/2 NPT, 2 NPTDrum Connector1 1/8"18 1/2" to 32 1/2"11/16"Removable2515K460000000
     

    Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.

    Style B

    Push the plunger to pump water, cleaners, and chemicals.
    Style B
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Style B are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
    Pumps
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Pipe
    Size
    Each
    PVC Piston
    857504012070 mmDrum Connector1/2"13"Tube End7/16"5/8"22"PVC
    9918K1120000002 NPT9918K111000000
     

    High-Flow Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Flow Peristaltic Pumps for Chemicals.
    For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    For Tube
    ID
    Connection
    For Tube
    ID
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase
     
    Plug In
    2,592201,00035 to 1601/43.11/2"Barbed
    1/2"Barbed
    10"5 1/2"10"10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61)4306K640000000
     
    Replacements for Peristaltic Pumps

    Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Contains Annotated. Drum Pumps. Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals.
    A filter/lubricator ensures efficiency and reduces wear on the pump. They have a chemically resistant seal for use with hydraulic oil and motor oil in addition to acidic and alkaline liquids such as ammonia and etching and cleaning solutions. Pumps have a nonsparking motor for use in applications where electricity is unavailable or dangerous.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube Lg.,
    ft.
    Tube
    Material
    Features
    Each
    Each
    16552,000-2015080 to 100322 NPTDrum Connector1/4 Female NPT1 1/2"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler8243K210000000008243K620000000
    16552,0003515080 to 100322 NPTDrum Connector1/4 Female NPT1 5/8"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler8243K31000000008243K62000000
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4100000000———0
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"48"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4800000000———0
     
    Couplings

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    Polypropylene Housing—Pumps with a polypropylene housing are often used with corrosives such as acid-washing solutions and cleaning and etching fluids. Their motors are rated IP44.
    Aluminum Housing—Pumps with an aluminum housing are often used with lubricating oil and coolants. Their motors are rated IP44.
    PVDF Housing—Pumps with a PVDF housing are often used with aggressive chemicals such as 98% nitric acid, hydrochloric acid, and sulfuric acid. Their motors are rated IP54.
    316 Stainless Steel Housing—Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
    47" Long Intake Tube—Pumps with a 47" intake tube can be used with large totes and tanks.
    Temp.
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Hazardous Location Rating
    Enclosure
    Rating
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—NEMA 5-15 Plug In
     
    Polypropylene Housing
    1515551,500Not Rated13017.52 NPT1 5/8"39"1"1 1/4"72"IP44
    Straight Blade37133T21000000000
    1515551,500Not Rated13017.52 NPT1 5/8"47"1"1 1/4"72"IP44
    Straight Blade37133T2200000000
     
    Aluminum Housing
    2215551,500Not Rated17517.52 NPT1 1/2"39"1"1 1/4"72"IP44
    Straight Blade37133T2500000000
    2215551,500Not Rated17517.52 NPT1 1/2"47"1"1 1/4"72"IP44
    Straight Blade37133T2600000000
     
    PVDF Housing
    1515551,500Not Rated17517.52 NPT1 5/8"39"1"1 1/4"72"IP54
    Straight Blade37133T2300000000
    1515551,500Not Rated17517.52 NPT1 5/8"47"1"1 1/4"72"IP54
    Straight Blade37133T2400000000
     
    120V AC—Single Phase—Hardwire
     
    316 Stainless Steel Housing
    1815551,000Not Rated1751 1/39.12 NPT1 1/2"39"1"1 1/4"72"NEC Class I Divisions 1, 2 Group D
    IP55
    7133T2700000000
     

    Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K410000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K42000000
     

    Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
    48.55514300-402101/25.341 mm1 5/8"39"Pump BodyBarbed
    1"MaleC-UL Listed
    UL Listed
    42675K4700000000042675K670000000
     
    Pump Replacement Parts

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K540000000008281K1110000000
     

    High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    Designed to move 40 gallons of liquid per minute, these pumps quickly empty drum contents. They're often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions.
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—Plug In
    403035500351601/25.72 NPTDrum Connector2"27"Tube End1"1 5/16"60"PVC
    Straight Blade36800K12000000000
    405535500-202201/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K3400000000
    405535500-202201/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K3800000000
    405535500351601/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1400000000
    405535500351601/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1800000000
     
    Pump Replacement Parts

    Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals.
    The polypropylene housing provides good resistance to caustics such as ammonia, electropolishing solutions, and detergents and cleaning fluids. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/regulator to ensure efficiency and reduce wear on the pump.
    PTFE Diaphragm—Choose a pump with a PTFE diaphragm for superior resistance to a wider variety of concentrated chemicals than Santoprene.
    Pump Repair Kits—Repair kits include components such as O-rings, valves, balls, and diaphragms.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    Santoprene Diaphragm
    13553,00030180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K1800000008281K460000000
    31558,00030180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K55000000008281K47000000
     
    PTFE Diaphragm
    13553,00040180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT8281K520000008281K111000000
    28558,00040180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K57000000008281K48000000
     

    Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
    Pump Body
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Pumps
    Pump Repair Kits
    Connectors
    Temp.
    Intake
    Discharge
    (Pump Body)
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Connection
    For Tube
    ID
    Connection
    No. of
    Blades
    Each
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    B0 to 3516551,500Not Rated17518.52"1 1/2"39"Barbed
    1"Straight Blade32850K550000000002850K9100000002850K940000000
    B0 to 3516551,500Not Rated17518.52"1 1/2"47"Barbed
    1"Straight Blade32850K56000000002850K910000002850K94000000
     
    Pump Replacement Parts

    Stainless Steel Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. Stainless Steel Long-Life Air-Powered Drum Pumps for Chemicals.
    A stainless steel construction allows these pumps to be used with aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include balls, O-rings, and diaphragms.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    28558,00040210100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT39"Pump BodyThreaded3/4 Female NPT8281K160000000008281K1410000000
     

    Air-Powered Drum Pumps for Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Air-Powered Drum Pumps for Flammable Liquid.
    These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Features
    Each
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger2824K39000000000
    26551,100-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger2824K4900000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"39"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger8252K1200000000
    53551,000-4021044 to 87532 NPTDrum Connector3/8 Female NPT1 5/8"47"Pump BodyBarbed
    1"MaleCE Marked
    Bonding and Grounding Wires, Hanger8252K1400000000
     
    Pump Replacement Parts
    back to top