We will reply to your message within an hour.
More
These switches use DC input voltage and produce PNP or NPN signal output. They're often used with programmable logic controllers (PLCs).
Sense objects from farther away than with other DC proximity switches that have the same diameter.
Easily mount these flat switches to a base or rail.
Use these switches to sense metallic objects in environments containing flammable gases and combustible dust. ATEX and IECEx certified to protect against explosion, they produce a low-current, low-voltage NAMUR signal, so they won’t ignite or create sparks.
These inductive proximity switches sense metallic objects each time they pass through the slot, even when they’re obscured by water, oil, dirt, or a surface finish. Use them to measure the speed of rotating equipment and to count or detect moving objects, such as sheet metal being fed into a stamping process.
Eliminate the need to calculate the sensing distance when using different metals—these switches sense all metal at the same distance. Also known as K=1 sensors.
Turn the face on these switches to sense metallic objects from the front, sides, top, or bottom.
Sense objects as they pass through the switch’s ring via tubing or a funnel. These switches are often used to monitor blockages, detect breaks in spooling wire, or count small metallic parts, such as screws, during the stamping process.
For use in volatile areas, these intrinsically safe switches detect objects when they pass through the slot. They use a NAMUR signal to operate at a low current and voltage, so they won’t ignite or create sparks. ATEX and IECEx certified, they protect against explosion.
Mount these intrinsically safe switches to flat surfaces in volatile areas. Their low-current, low-voltage NAMUR signal means they won’t ignite or create sparks while in use. ATEX and IECEx certified, they meet international standards to protect against explosion where combustible dust and flammable gases are present.
Twist the sensor to detect metallic objects where explosive dust or gas may be present—the sensor rotates for front, side, top, or bottom sensing. These switches are UL and C-UL listed as well as ATEX and IECEx certified for hazardous locations.
These intrinsically safe switches detect objects as they’re routed through the ring. They produce a low-current, low-voltage NAMUR signal, so they won’t ignite or create sparks. Switches are ATEX certified to protect against explosion.
Switches accept both AC and DC input voltage.
Mount these flat inductive switches to a base or rail to remotely detect metallic objects in wet and dirty environments.
These switches have a longer sensing distance compared to other proximity switches with the same diameter.
Most often found in older devices, these switches require AC input voltage.
Rotate the face on these switches five different directions for easy installation and positioning—they work with both AC and DC inputs.
Detect the presence or absence of an object moving at high speeds with a light beam. These switches have a longer sensing distance than proximity and ultrasonic switches.
A built-in relay produces AC voltage output. These switches are often used with older programmable logic controllers (PLCs).
Set these switches to delay activation by up to five seconds after detecting an object.
For optimal performance in tight spaces, these switches have a smaller beam and can detect smaller objects than standard photoelectric switches.
With a narrow, flat body, these switches fit in tight spaces.
Safely detect the presence or absence of an object moving at high speeds with a light beam. These switches produce a low-current, low-voltage NAMUR signal, so they won’t create sparks or ignite. ATEX and IECEx certified, they protect against explosion in environments containing flammable gases and combustible dust.
Verify the signal output type of DC switches—a red light indicates NPN, and a green light indicates PNP.
Wire contacts to an alarm system to alert when doors or windows are opened.
These switches actuate when a magnet comes within sensing distance, and reset when the magnet moves away.
Prevent unauthorized use—these switches require coded magnets to actuate. They cannot be bypassed using ordinary magnets.
Keep your phone in your pocket and your hands free—these smartwatches perform a variety of functions on your wrist.
Use a laser to determine the distance to an object up to 700 yards away.
Roll these wheels along a surface to measure distances up to 99,999 feet.
Record steps or miles while you walk or run.
Slide this ruler across the surface of plans, maps, and blueprints and read the measurement on the digital display in one of 111 different scales including inches, feet, yards, miles, centimeters, meters, kilometers, or a scale you define.
Send sheet, roll, and strip measurements from this measurer to a remote Voltage Actuated Counter (sold separately).
Measure sheets, rolls, and strips using these wheels and their attached counters.
Navigate on foot with real-time GPS data.
Accurate to within ±0.006% of reading, these tachometers come with a calibration certificate traceable to NIST that states they've passed a test for accuracy.
This switch mounts to the outside of your tank and detects chemical level through plastic tank walls by measuring the capacitance between the switch and tank contents; it cannot be used with metal tanks.
Use high-frequency sound waves to detect chemical level.
Detect chemical level with infrared light to avoid false switch activation caused by vibration in your tank.
Measure the level of conductive liquids without drilling a hole in your tank—these switches mount to the outside of the tank and track the capacitance between them and the tank’s contents.
Cut the probes on these switches to fit the size of your tank.
Short probes are built into the tip of these switches.
Detect when oil rises on water, foam forms on beer, and tanks empty, triggering pumps and valves in food and sanitary lines. These switches are 3-A and European Hygienic Engineering and Design Group (EHEDG) certified since they’re easy to keep clean.
Detect water level with infrared light to avoid false switch activation caused by vibration in your tank.
Send an electronic signal to your system when the piston reaches a certain location.
To provide more mounting flexibility than other sensor and switch mounting brackets, the head rotates 360°.
Clamp around sensors and switches for a secure hold.
Position proximity, photoelectric, and light beam sensors and switches.
The spring-loaded design absorbs impact to protect sensors and switches from damage.
Designed to fit most limit switches, these brackets allow switch-position adjustments after they are fastened to equipment.
The five-digit counter on these dispensers measures distance as you go. Pull the trigger to release a line of paint.