NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L6-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 000000 |
L25-30 | 240V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, C-UL Listed | Black | 0000000 | 00000 |
Non-Grounded | ||||||||||
L10-30 | 125V AC/250V AC | 30A | 1.7" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 00000 |
L11-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 00000000 | 00000 |



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L14-30 | 125V AC/250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 000000 |
L15-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 00000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Specifications Met | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L6-30 | 250V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |
Non-Grounded | |||||||||
L10-30 | 125V AC/250V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 00000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Specifications Met | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L14-30 | 125V AC/250V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |
L15-30 | 250V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 00000 |
Premium Turn-Lock Plugs, Sockets, and Receptacles
Also known as twist-lock devices, these connectors are built to handle tough, repetitive-use applications, and are more durable than standard turn-lock connectors. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Receptacles for outlet boxes fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Environmental Rating | Specifications Met | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
L6-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 000000 |
Non-Grounded | |||||||||||
L10-30 | 125V AC/250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 00000000 | 00000 |



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Environmental Rating | Specifications Met | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
L14-30 | 125V AC/250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 000000 |
L15-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 00000 |


NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Color | Environmental Rating | Specifications Met | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L6-30 | 250V AC | 30A | Screw Terminals | Back | 2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 00000000 | 000000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Color | Environmental Rating | Specifications Met | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L14-30 | 125V AC/250V AC | 30A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 00000000 | 000000 |
L15-30 | 250V AC | 30A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 00000000 | 00000 |
Interference-Limiting Turn-Lock Receptacles
Protect computers and other sensitive equipment from electromagnetic interference (EMI). Also known as isolated ground receptacles, they have a ground terminal that is insulated from the mounting strap so you can run an isolated ground wire through the conduit. When mated with a plug, a quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection. Receptacles fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L6-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Green Triangle, Isolated Ground Connection | Orange | 0000000 | 000000 |


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L14-30 | 125V AC/250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Green Triangle, Isolated Ground Connection | Orange | 0000000 | 000000 |
Washdown Turn-Lock Connectors and Cords
When mated, connectors meet NEMA 6P for protection against corrosion and washdowns. All have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
For technical drawings and 3-D models, click on a part number.


Corrosion-Resistant Turn-Lock Connectors
Stainless steel hardware and nickel-plated blades or slots protect connectors from damage in corrosive environments. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Receptacles fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Environmental Rating | Specifications Met | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
L6-30 | 250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498, UL 94 HB | Yellow | 0000000 | 000000 |


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L14-30 | 125V AC/250V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, C-UL Listed, CSA Certified | Yellow | 0000000 | 000000 |
Non-NEMA Turn-Lock Connectors
A quarter turn locks these connectors in place to remain secure in high-vibration applications and prevent accidental disconnection. They are not compatible with NEMA configurations.
Receptacles fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.


Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
F | 125V AC/250V AC | 30A | 1.6" | Screw Terminals | Back | Outlet Box | UL Listed, CSA Certified, UL 498, UL 94 HB, Fed. Spec. W-C-596 | Black | 0000000 | 000000 |
Premium Straight-Blade Plugs, Sockets, and Receptacles
Built to handle tough, repetitive-use applications, these are more durable than standard straight-blade connectors.
Receptacles for outlet boxes fit standard wall plates (not included).
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Environmental Rating | Specifications Met | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6-30 | 250V AC | 30A | 2.1" | Screw Terminals | Back | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 V-0 | Black | 0000000 | 000000 |
Non-Grounded | |||||||||||
10-30 | 125V AC/250V AC | 30A | 2.1" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, UL 94 V-1 | Black | 0000000 | 00000 |



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Environmental Rating | Specifications Met | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
14-30 | 125V AC/250V AC | 30A | 2.4" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 V-0 | Black | 0000000 | 0000000 |
15-30 | 250V AC | 30A | 2.4" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 V-0 | Black | 0000000 | 000000 |
Straight-Blade Plugs, Sockets, and Receptacles
Receptacles for outlet boxes fit standard wall plates (not included).
Note: The current rating of your plug should not exceed that of your socket or receptacle.


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
14-30 | 125V AC/250V AC | 30A | 2.1" | Screw Terminals | Back | Outlet Box | Black | 0000000 | 000000 |