Dynamic Push Load Capacity Dynamic Push Load Capacity |
---|
|
|
Retracted Length Retracted Length |
---|

Dynamic Pull Load Capacity Dynamic Pull Load Capacity |
---|
|
|
Maximum Speed Maximum Speed |
---|
|
|
Duty Cycle Duty Cycle |
---|
|
Static Load Capacity Static Load Capacity |
---|
|
Extension Rod Type Extension Rod Type |
---|
|
Overall Height Overall Height |
---|

|
|
|
Stroke Protection Type Stroke Protection Type |
---|
|
On/Off Time On/Off Time |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
Rod End Location Rod End Location |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Electric Actuators




Move loads with consistent, repeatable push-pull motion. These actuators hold their loads in position even if power fails. Some actuators have a brake that prevents loads from shifting even slightly, so they’re best for vertical and high-vibration applications.
To protect the motor from overload when the extension rod is at the end of the stroke, all actuators have either a limit switch or clutch. Fixed limit switches cannot be moved to adjust the length of the stroke. Move adjustable limit switches to change the length of the stroke. Actuators with a load-limiting clutch also protect the motor from jams and impact or shock loads. If the load exceeds the maximum capacity or if the extension rod reaches the end of its stroke, the clutch slips and stops the rod from moving. You can set the clutch to slip at a specific load capacity.
Actuators with automatic overload protection prevent damage to the motor from overheating. They have a switch that shuts off the motor if it’s too warm or if it exceeds the maximum duty cycle. The switch automatically resets once the motor is cool enough to operate.
All actuators have a clevis hole on each end for mounting. Secure both ends of actuators with rotating extension rods to fixed surfaces, so the rod extends and retracts instead of rotates. Twist the extension rod until the clevis holes line up with your mounting bracket. Only the motor body end of actuators with nonrotating extension rods needs to be mounted to a fixed surface. Their clevis ends cannot twist.
Maximum speed is how fast the actuator will move under no-load conditions. If you increase the load, the actuator speed will decrease. Use a speed-load chart to confirm which actuator will work for your application. Click on a part number and select “Product Detail” to view the chart for an actuator.
For technical drawings and 3-D models, click on a part number.
Actuators | Replacement Connectors | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Stroke Lg. | Voltage | Full Load Current | Max. Speed, in./sec. | Overload Protection Type | Extension Rod Type | Environmental Rating | Retracted Lg. | Features | Each | Each | ||
25 lbs. Dynamic Pull/Push Load | ||||||||||||
With Fixed Limit Switches | ||||||||||||
2" | 12V DC | 3.8A | 3 | Automatic | Rotating | IP66 | 7" | __ | 0000000 | 0000000 | 0000000 | 000000 |
2" | 24V DC | 1.6A | 3 | Automatic | Rotating | IP66 | 7" | __ | 0000000 | 000000 | 0000000 | 00000 |
4" | 12V DC | 3.8A | 3 | Automatic | Rotating | IP66 | 9" | __ | 0000000 | 000000 | 0000000 | 00000 |
4" | 24V DC | 1.6A | 3 | Automatic | Rotating | IP66 | 9" | __ | 0000000 | 000000 | 0000000 | 00000 |
6" | 12V DC | 3.8A | 3 | Automatic | Rotating | IP66 | 11" | __ | 0000000 | 000000 | 0000000 | 00000 |
6" | 24V DC | 1.6A | 3 | Automatic | Rotating | IP66 | 11" | __ | 0000000 | 000000 | 0000000 | 00000 |
100 lbs. Dynamic Pull/Push Load | ||||||||||||
With Adjustable Limit Switches | ||||||||||||
2" | 12V DC | 7A | 1 | None | Nonrotating | IP50 | 7 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
2" | 24V DC | 5A | 1.4 | None | Nonrotating | IP50 | 7 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
4" | 12V DC | 7A | 1 | None | Nonrotating | IP50 | 9 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
4" | 24V DC | 5A | 1.4 | None | Nonrotating | IP50 | 9 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
6" | 24V DC | 5A | 1.4 | None | Nonrotating | IP50 | 11 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
8" | 12V DC | 7A | 1 | None | Nonrotating | IP50 | 13 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
8" | 24V DC | 5A | 1.4 | None | Nonrotating | IP50 | 13 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
10" | 24V DC | 5A | 1.4 | None | Nonrotating | IP50 | 15 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
12" | 12V DC | 7A | 1 | None | Nonrotating | IP50 | 17 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
12" | 24V DC | 5A | 1.4 | None | Nonrotating | IP50 | 17 1/4" | __ | 00000000 | 000000 | 000000 | 00 |
250 lbs. Dynamic Pull/Push Load | ||||||||||||
With Adjustable Limit Switches | ||||||||||||
2" | 12V DC | 7A | 0.58 | None | Nonrotating | IP50 | 7 5/8" | __ | 0000000 | 000000 | 000000 | 00 |
2" | 24V DC | 4.5A | 1 | None | Nonrotating | IP50 | 7 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
4" | 12V DC | 7A | 0.58 | None | Nonrotating | IP50 | 9 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
4" | 24V DC | 4.5A | 1 | None | Nonrotating | IP50 | 9 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
8" | 12V DC | 7A | 0.58 | None | Nonrotating | IP50 | 13 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
8" | 24V DC | 4.5A | 1 | None | Nonrotating | IP50 | 13 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
12" | 12V DC | 7A | 0.58 | None | Nonrotating | IP50 | 17 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
12" | 24V DC | 4.5A | 1 | None | Nonrotating | IP50 | 17 5/8" | __ | 00000000 | 000000 | 000000 | 00 |
500 lbs. Dynamic Pull/Push Load | ||||||||||||
With Adjustable Limit Switches | ||||||||||||
6" | 120V AC | 2.3A | 0.7 | Automatic | Rotating | IP50 | 15 1/2" | Brake | 0000000 | 00000000 | 000000 | 00 |
12" | 24V DC | 12A | 1.25 | Automatic | Rotating | IP50 | 21 3/8" | Brake | 00000000 | 00000000 | 000000 | 00 |
12" | 120V AC | 2.3A | 0.7 | Automatic | Rotating | IP50 | 21 1/2" | Brake | 0000000 | 00000000 | 000000 | 00 |
18" | 24V DC | 12A | 1.25 | Automatic | Rotating | IP50 | 27 3/8" | Brake | 0000000 | 00000000 | 000000 | 00 |
18" | 120V AC | 2.3A | 0.7 | Automatic | Rotating | IP50 | 27 1/2" | Brake | 0000000 | 00000000 | 000000 | 00 |
With Load-Limiting Clutch | ||||||||||||
6" | 12V DC | 22A | 1.125 | Automatic | Rotating | IP50 | 15 1/2" | Brake | 0000000 | 000000 | 000000 | 00 |
6" | 120V AC | 2.1A | 0.7 | Automatic | Rotating | IP50 | 14 1/4" | Brake | 0000000 | 000000 | 000000 | 00 |
12" | 12V DC | 22A | 1.125 | Automatic | Rotating | IP50 | 21 1/2" | Brake | 0000000 | 00000000 | 000000 | 00 |
12" | 120V AC | 2.1A | 0.7 | Automatic | Rotating | IP50 | 20 1/4" | Brake | 0000000 | 000000 | 000000 | 00 |
18" | 12V DC | 22A | 1.125 | Automatic | Rotating | IP50 | 27 1/2" | Brake | 0000000 | 00000000 | 000000 | 00 |
18" | 120V AC | 2.1A | 0.7 | Automatic | Rotating | IP50 | 26 1/4" | Brake | 0000000 | 00000000 | 000000 | 00 |
1,500 lbs. Dynamic Pull/Push Load | ||||||||||||
With Adjustable Limit Switches | ||||||||||||
3" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 18 7/8" | Brake | 0000000 | 00000000 | 000000 | 00 |
6" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 21 7/8" | Brake | 0000000 | 00000000 | 000000 | 00 |
12" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 27 7/8" | Brake | 0000000 | 00000000 | 000000 | 00 |
18" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 33 7/8" | Brake | 0000000 | 00000000 | 000000 | 00 |
24" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 39 7/8" | Brake | 00000000 | 00000000 | 000000 | 00 |
30" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 51 7/8" | Brake | 00000000 | 00000000 | 000000 | 00 |
36" | 120V AC | 6.5A | 0.87 | Automatic | Rotating | IP50 | 57 7/8" | Brake | 00000000 | 00000000 | 000000 | 00 |
Water-Resistant Sealed Linear Solenoids

Great for use in damp and dirty environments, these solenoids meet IP65 for protection from dust and spraying water. They have two-pin plugs that are compatible with Deutsch-style DC connectors (sold separately). They can be used to pull or push. To pull, install them with the connector pins facing your device; to push, install them facing away.
For technical drawings and 3-D models, click on a part number.

Length | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | On/Off Time, Minutes | Wd. | Ht. | Rod Dia. (R) | Environmental Rating | Each | |
For DC Voltage | |||||||||||||
Pull/Push | |||||||||||||
0.39" | 4.6" | 4.6" | 4.6" | 115 | 50 | 1/3 | 2 1/4" | 2 1/4" | 0.2" | IP65 | 00000000 | 0000000 | |
0.51" | 4.7" | 4.7" | 4.7" | 177 | 60 | 1/3 | 2 7/8" | 2 3/4" | 0.2" | IP65 | 00000000 | 000000 |
Sealed Linear Solenoids


Spend less time on solenoid maintenance in dirty environments—these have a closed steel housing that keeps dust out.
Pull solenoids exert force when the rod retracts.
Push solenoids exert force when the rod extends.
For technical drawings and 3-D models, click on a part number.
Length | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | On/Off Time, Minutes | Dia. | Wd. | Ht. | Rod Dia. (R) | Each | |
For DC Voltage | |||||||||||||
Pull | |||||||||||||
1/4" | 1.6" | 1.9" | 1.9" | 5 | 7.5 | 1/9 | 1/2" | 1/2" | 1/2" | 0.2" | 000000000 | 000000 | |
1/2" | 2.4" | 2.9" | 2.9" | 15 | 24 | 1/9 | 3/4" | 3/4" | 3/4" | 1/4" | 000000000 | 00000 | |
1" | 2.9" | 3.9" | 3.9" | 29 | 38 | 1/9 | 1" | 1" | 1" | 0.44" | 000000000 | 00000 | |
1" | 3.3" | 4.3" | 4.3" | 79 | 59 | 1/9 | 1 1/2" | 1 1/2" | 1 1/2" | 1/2" | 000000000 | 00000 | |
Push | |||||||||||||
1/4" | 1.5" | 1.7" | 1.7" | 3 | 7.5 | 1/9 | 1/2" | 1/2" | 1/2" | 0.06" | 000000000 | 00000 | |
1/2" | 2.6" | 3.1" | 3.1" | 78 | 41 | 1/9 | 1 1/2" | 1 1/2" | 1 1/2" | 0.19" | 000000000 | 00000 | |
1/2" | 2.8" | 3.3" | 3.3" | 25 | 38 | 1/9 | 1" | 1" | 1" | 0.11" | 000000000 | 00000 | |
1" | 3.4" | 4.4" | 4.4" | 68 | 59 | 1/9 | 1 1/2" | 1 1/2" | 1 1/2" | 0.19" | 000000000 | 00000 |
Length | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | Dia. | Wd. | Ht. | Rod Dia. (R) | Each | |
For DC Voltage | ||||||||||||
Pull | ||||||||||||
1/4" | 1.6" | 1.9" | 1.9" | 2 | 2.5 | 1/2" | 1/2" | 1/2" | 0.2" | 000000000 | 000000 | |
1/2" | 2.4" | 2.9" | 2.9" | 4 | 3.5 | 3/4" | 3/4" | 3/4" | 1/4" | 000000000 | 00000 | |
1" | 2.9" | 3.9" | 3.9" | 5 | 5.5 | 1" | 1" | 1" | 0.44" | 000000000 | 00000 | |
1" | 3.3" | 4.3" | 4.3" | 17 | 10 | 1 1/2" | 1 1/2" | 1 1/2" | 1/2" | 000000000 | 00000 | |
Push | ||||||||||||
1/4" | 1.5" | 1.7" | 1.7" | 1 | 2.5 | 1/2" | 1/2" | 1/2" | 0.06" | 000000000 | 00000 | |
1/2" | 2.6" | 3.1" | 3.1" | 14 | 7 | 1 1/2" | 1 1/2" | 1 1/2" | 0.19" | 000000000 | 00000 | |
1/2" | 2.8" | 3.3" | 3.3" | 7 | 5.5 | 1" | 1" | 1" | 0.11" | 000000000 | 00000 | |
1" | 3.4" | 4.4" | 4.4" | 11 | 10 | 1 1/2" | 1 1/2" | 1 1/2" | 0.19" | 000000000 | 00000 |
Extended-Life Sealed Linear Solenoids

In addition to a closed steel housing that keeps out dust, these solenoids have a PTFE coating on the rod to minimize friction for a long service life. All are pull solenoids—they exert force when the rod retracts.
For technical drawings and 3-D models, click on a part number.

Length | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | On/Off Time, Minutes | Dia. | Wd. | Ht. | Rod Dia. (R) | Each | |
For DC Voltage | |||||||||||||
Pull | |||||||||||||
1/4" | 1.8" | 2" | 2" | 2 | 5.6 | 1.7/5 | 1/2" | 1/2" | 1/2" | 0.16" | 0000000 | 0000000 | |
1/2" | 2.4" | 2.9" | 2.9" | 10 | 11 | 1.7/5 | 3/4" | 3/4" | 3/4" | 0.31" | 0000000 | 00000 | |
3/4" | 3.1" | 3.9" | 3.9" | 25 | 20.4 | 1.7/5 | 1" | 1" | 1" | 0.44" | 0000000 | 00000 | |
1" | 3.4" | 4.4" | 4.4" | 45 | 32.4 | 1.7/5 | 1 1/2" | 1 1/2" | 1 1/2" | 1/2" | 0000000 | 000000 |

Length | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | Dia. | Wd. | Ht. | Rod Dia. (R) | Each | |
For DC Voltage | ||||||||||||
Pull | ||||||||||||
1/4" | 1.8" | 2" | 2" | 2 | 2.7 | 1/2" | 1/2" | 1/2" | 0.16" | 0000000 | 000000 | |
1/2" | 2.4" | 2.9" | 2.9" | 5 | 4.3 | 3/4" | 3/4" | 3/4" | 0.31" | 0000000 | 00000 | |
3/4" | 3.1" | 3.9" | 3.9" | 9 | 7.8 | 1" | 1" | 1" | 0.44" | 0000000 | 00000 | |
1" | 3.4" | 4.4" | 4.4" | 15 | 8.4 | 1 1/2" | 1 1/2" | 1 1/2" | 1/2" | 0000000 | 000000 |
Linear Solenoids



Create linear motion economically with one of these open-frame solenoids.
Pull solenoids exert force when the rod retracts.
Push solenoids exert force when the rod extends.
Pull/push solenoids exert force when the rod retracts and extends.
For technical drawings and 3-D models, click on a part number.
Length | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | On/Off Time, Minutes | Wd. | Ht. | Rod Dia. (R) | Specifications Met | Each | |
For AC Voltage, 60 Hz | |||||||||||||
Pull | |||||||||||||
1/2" | 1.7" | 2.2" | 2.2" | 13 | __ | 18 | 1/3 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 000000 |
1/2" | 2.5" | 3" | 3" | 22 | __ | 40.9 | 1/3 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 00000 |
1" | 3.2" | 4.2" | 4.3" | 34 | __ | 57.6 | 1/3 | 1 3/4" | 1 3/4" | 0.44" | UL Recognized Component | 000000000 | 00000 |
Push | |||||||||||||
1/2" | 1.9" | 1.9" | 2" | 13 | __ | 23 | 1/3 | 1 1/4" | 1 1/4" | 0.09" | UL Recognized Component | 000000000 | 00000 |
1/2" | 3.1" | 3.1" | 3.3" | 21 | __ | 52.4 | 1/3 | 1 1/4" | 1 1/4" | 0.09" | UL Recognized Component | 000000000 | 00000 |
For DC Voltage | |||||||||||||
Pull | |||||||||||||
1/2" | 1.7" | 2.2" | 2.2" | 9 | 11.5 | 1/3 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 00000 | |
1/2" | 2.5" | 3" | 3" | 26 | 19 | 1/3 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 00000 | |
1" | 3.2" | 4.2" | 4.3" | 52 | 38 | 1/3 | 1 3/4" | 1 3/4" | 0.44" | UL Recognized Component | 000000000 | 00000 | |
Pull/Push | |||||||||||||
0.19" | 2" | 2.2" | 2.2" | 8 | 7.2 | 0.2/1.5 | 1" | 3/4" | 0.13" | __ | 00000000 | 000000 | |
Push | |||||||||||||
1/2" | 3.1" | 3.1" | 3.3" | 26 | 19 | 1/3 | 1 1/4" | 1 1/4" | 0.09" | UL Recognized Component | 000000000 | 00000 | |
1" | 3.2" | 3.2" | 3.2" | 13 | 30 | 0.8/2.5 | 1" | 1 1/4" | 0.13" | __ | 00000000 | 00000 |
Length | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | Wd. | Ht. | Rod Dia. (R) | Specifications Met | Each | |
For AC Voltage, 60 Hz | ||||||||||||
Pull | ||||||||||||
1/2" | 1.7" | 2.2" | 2.2" | 10 | __ | 7.2 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 000000 |
1/2" | 2.5" | 3" | 3" | 10 | __ | 11.5 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 00000 |
1" | 3.2" | 4.2" | 4.3" | 9 | __ | 9 | 1 3/4" | 1 3/4" | 0.44" | UL Recognized Component | 000000000 | 00000 |
Push | ||||||||||||
1/2" | 1.9" | 1.9" | 2" | 8 | __ | 7.8 | 1 1/4" | 1 1/4" | 0.09" | UL Recognized Component | 000000000 | 00000 |
1/2" | 3.1" | 3.1" | 3.3" | 8 | __ | 12.5 | 1 1/4" | 1 1/4" | 0.09" | UL Recognized Component | 000000000 | 00000 |
For DC Voltage | ||||||||||||
Pull | ||||||||||||
1/2" | 1.7" | 2.2" | 2.2" | 4 | 5 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 00000 | |
1/2" | 2.5" | 3" | 3" | 15 | 8 | 1 1/4" | 1 1/4" | 0.31" | UL Recognized Component | 000000000 | 00000 | |
1" | 3.2" | 4.2" | 4.3" | 18 | 11 | 1 3/4" | 1 3/4" | 0.44" | UL Recognized Component | 000000000 | 00000 | |
Push | ||||||||||||
1/2" | 3.1" | 3.1" | 3.3" | 15 | 8 | 1 1/4" | 1 1/4" | 0.09" | UL Recognized Component | 000000000 | 00000 | |
1" | 3.2" | 3.2" | 3.2" | 3 | 7.5 | 1" | 1 1/4" | 0.13" | __ | 00000000 | 00000 |
Compact Linear Solenoids

A thin profile allows these solenoids to fit well in narrow spaces. You can use them to push or pull—use the side with the unthreaded rod (R) and two mounting studs to push or use the opposite side with the threaded rod to pull.
For technical drawings and 3-D models, click on a part number.

Rod Length (Pulling) | Rod Length (Pushing) | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Retracted | Extended | Force @ 100% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | On/Off Time, Seconds | Dia. | Lg. | Rod Dia. (R) | Each | |
For DC Voltage | |||||||||||||
Pull/Push | |||||||||||||
0.2" | 0.5" | 0.7" | 0.3" | 0.5" | 7 | 18 | 30/90 | 1 1/4" | 1 1/2" | 0.16" | 000000 | 000000 | |
0.3" | 0.6" | 0.9" | 0.2" | 0.5" | 1 | 16 | 20/60 | 1" | 1 3/4" | 0.13" | 000000 | 00000 | |
0.7" | 1.9" | 2.6" | 0.3" | 1" | 50 | 80 | 90/270 | 2 3/4" | 4 3/4" | 0.38" | 000000 | 000000 |

Rod Length (Pulling) | Rod Length (Pushing) | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Retracted | Extended | Force @ 100% Stroke Lg., oz. | Choose a Voltage | Power Draw, Watts | Dia. | Lg. | Rod Dia. (R) | Each | |
For DC Voltage | ||||||||||||
Pull/Push | ||||||||||||
0.2" | 0.5" | 0.7" | 0.3" | 0.5" | 2 | 4.5 | 1 1/4" | 1 1/2" | 0.16" | 000000 | 000000 | |
0.2" | 0.6" | 0.8" | 0.3" | 0.5" | 2 | 4 | 1" | 1 3/4" | 0.13" | 000000 | 00000 | |
0.5" | 1.9" | 2.4" | 0.5" | 1" | 45 | 20 | 2 3/4" | 4 3/4" | 0.38" | 000000 | 000000 |
High-Force Linear Solenoids


High-force solenoids draw more power than our other open-frame solenoids, so they can deliver higher force. They also have a laminated rod that minimizes friction during operation.
Pull solenoids exert force when the rod retracts.
Push solenoids exert force when the rod extends.
For technical drawings and 3-D models, click on a part number.
Length | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Voltage | Power Draw, Watts | On/Off Time, Minutes | Wd. | Ht. | Rod Dia. (R) | Each | |
For AC Voltage, 60 Hz | ||||||||||||
Pull | ||||||||||||
1" | 2.3" | 3" | 3" | 60 | 120V AC | 70 | 2.5/22.5 | 1 1/2" | 1 1/2" | 0.36" | 000000 | 0000000 |
1" | 2.7" | 3.4" | 3.4" | 195 | 120V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
1" | 2.7" | 3.4" | 3.4" | 195 | 240V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
Push | ||||||||||||
0.82" | 3" | 3" | 3" | 60 | 120V AC | 70 | 2.5/22.5 | 1 1/2" | 1 1/2" | 0.13" | 000000 | 000000 |
1" | 3 1/2" | 3.5" | 3.5" | 195 | 120V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.19" | 0000000 | 000000 |
Length | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Voltage | Power Draw, Watts | Wd. | Ht. | Rod Dia. (R) | Each | |
For AC Voltage, 60 Hz | |||||||||||
Pull | |||||||||||
1" | 2.3" | 3" | 3" | 30 | 120V AC | 20 | 1 1/2" | 1 1/2" | 0.36" | 000000 | 0000000 |
1" | 2.7" | 3.4" | 3.4" | 105 | 120V AC | 49 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
1" | 2.7" | 3.4" | 3.4" | 105 | 240V AC | 49 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 00000 |
Push | |||||||||||
0.82" | 3" | 3" | 3" | 30 | 120V AC | 20 | 1 1/2" | 1 1/2" | 0.13" | 0000000 | 000000 |
1" | 3 1/2" | 3.5" | 3.5" | 105 | 120V AC | 49 | 1 7/8" | 2 1/8" | 0.19" | 0000000 | 000000 |
Rotary Solenoids

If your application requires rotary motion, take one of these solenoids for a spin.
For technical drawings and 3-D models, click on a part number.

Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
Max. Stroke Rotation | Torque @ 50% Rotation, in.-oz. | Choose a Direction of Force | Power Draw, Watts | On/Off Time, Minutes | Dia. | Lg. | Rod Dia. (R) | Each | |
12V DC | |||||||||
40° | 11.2 | 36 | 1/3 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 0000000 | |
40° | 17 | 40 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 24 | 44 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 41 | 48 | 3.5/10.5 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 | |
24V DC | |||||||||
40° | 11.2 | 36 | 1/3 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 000000 | |
40° | 17 | 40 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 24 | 44 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 41 | 48 | 3.5/10.5 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 |

Overall | ||||||||
---|---|---|---|---|---|---|---|---|
Max. Stroke Rotation | Torque @ 50% Rotation, in.-oz. | Choose a Direction of Force | Power Draw, Watts | Dia. | Lg. | Rod Dia. (R) | Each | |
12V DC | ||||||||
40° | 2.8 | 9 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 0000000 | |
40° | 6.8 | 10 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 9.5 | 11 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 16 | 12 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 | |
24V DC | ||||||||
40° | 2.8 | 9 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 000000 | |
40° | 6.8 | 10 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 9.5 | 11 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 | |
40° | 16 | 12 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 |
Plug-In Electric Actuators with Manual Controls
Without any hardwiring, these actuators give you control over your push-pull motion using either a hand or foot switch. Plug the actuator and the hand or foot switch into the control box (all sold separately). If power fails, actuators hold their loads in position. The brake prevents loads from shifting even slightly, making these actuators useful in vertical and high-vibration applications. Both actuator ends must be secured to fixed surfaces for the rod to extend and retract rather than rotate. Twist the extension rod until the clevis holes line up with your mounting holes. Fasten with clevis pins.
Control boxes supply power to actuators and switches. They have their own overload protection switch, which prevents damage to the actuator from overheating. If triggered, manually reset the switch after the actuator has cooled.
Switches have separate buttons to extend and retract each actuator they control. Some switches can be used to operate as many as three separate actuators.
IP04 rated actuators stand up to splashing water. IP66 rated actuators seal out dust and water from washdowns.
Maximum speed is how fast the actuator will move under no-load conditions. If you increase the load, the actuator speed will decrease. Use a speed-load chart to confirm which actuator will work for your application. Click on a part number and select “Product Detail” to view the chart for an actuator.
For technical drawings and 3-D models, click on a part number.


Actuators | Control Boxes | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Stroke Lg. | Voltage | Full Load Current | Max. Speed, in./sec. | Extension Rod Type | Cord Lg., ft. | Retracted Lg. | Features | Each | Each | ||
For Damp Environments—IP04 | |||||||||||
449 lbs. Dynamic Pull Load/449 lbs. Dynamic Push Load | |||||||||||
2" | 24V DC | 4A | 0.52 | Rotating | 1 1/2 | 9 1/2" | Brake | 0000000 | 0000000 | 0000000 | 0000000 |
4" | 24V DC | 4A | 0.52 | Rotating | 1 1/2 | 11 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
6" | 24V DC | 4A | 0.52 | Rotating | 1 1/2 | 13 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
8" | 24V DC | 4A | 0.52 | Rotating | 1 1/2 | 15 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
10" | 24V DC | 4A | 0.52 | Rotating | 1 1/2 | 17 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
12" | 24V DC | 4A | 0.52 | Rotating | 1 1/2 | 19 1/4" | Brake | 0000000 | 000000 | 0000000 | 000000 |
899 lbs. Dynamic Pull Load/1,348 lbs. Dynamic Push Load | |||||||||||
2" | 24V DC | 6A | 0.28 | Rotating | 1 1/2 | 9 1/2" | Brake | 0000000 | 000000 | 0000000 | 000000 |
4" | 24V DC | 6A | 0.28 | Rotating | 1 1/2 | 11 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
6" | 24V DC | 6A | 0.28 | Rotating | 1 1/2 | 13 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
8" | 24V DC | 6A | 0.28 | Rotating | 1 1/2 | 15 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
10" | 24V DC | 6A | 0.28 | Rotating | 1 1/2 | 17 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
12" | 24V DC | 6A | 0.28 | Rotating | 1 1/2 | 19 1/4" | Brake | 0000000 | 000000 | 0000000 | 000000 |
For Damp, Dusty, and Washdown Environments—IP66 | |||||||||||
337 lbs. Dynamic Pull Load/337 lbs. Dynamic Push Load | |||||||||||
3" | 24V DC | 5A | 0.7 | Rotating | 2 1/2 | 12" | Brake | 0000000 | 000000 | 0000000 | 000000 |
6" | 24V DC | 5A | 0.7 | Rotating | 2 1/2 | 14 3/4" | Brake | 0000000 | 000000 | 0000000 | 000000 |
12" | 24V DC | 5A | 0.7 | Rotating | 2 1/2 | 20 5/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
18" | 24V DC | 5A | 0.7 | Rotating | 2 1/2 | 29 1/2" | Brake | 0000000 | 000000 | 0000000 | 000000 |
674 lbs. Dynamic Pull Load/674 lbs. Dynamic Push Load | |||||||||||
3" | 24V DC | 5.2A | 0.7 | Rotating | 2 1/2 | 12 3/4" | Brake | 0000000 | 000000 | 0000000 | 000000 |
6" | 24V DC | 5.2A | 0.7 | Rotating | 2 1/2 | 15 1/2" | Brake | 0000000 | 000000 | 0000000 | 000000 |
12" | 24V DC | 5.2A | 0.7 | Rotating | 2 1/2 | 21 1/2" | Brake | 0000000 | 000000 | 0000000 | 000000 |
18" | 24V DC | 5.2A | 0.7 | Rotating | 2 1/2 | 30 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |
1,348 lbs. Dynamic Pull Load/1,798 lbs. Dynamic Push Load | |||||||||||
3" | 24V DC | 5A | 0.28 | Rotating | 2 1/2 | 12 3/4" | Brake | 0000000 | 000000 | 0000000 | 000000 |
6" | 24V DC | 5A | 0.28 | Rotating | 2 1/2 | 15 1/2" | Brake | 0000000 | 000000 | 0000000 | 000000 |
12" | 24V DC | 5A | 0.28 | Rotating | 2 1/2 | 21 1/2" | Brake | 0000000 | 000000 | 0000000 | 000000 |
18" | 24V DC | 5A | 0.28 | Rotating | 2 1/2 | 30 3/8" | Brake | 0000000 | 000000 | 0000000 | 000000 |


For No. of Actuators | Cord Lg., ft. | Voltage | Current | Lg. | Wd. | Dp. | Environmental Rating | Button Type | Features | Each | |
Hand | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 8 | 12V DC | 50mA | 6" | 2 1/4" | 1 1/8" | IP67 | Extend, Retract | Belt Clip | 0000000 | 0000000 |
2 | 8 | 12V DC | 50mA | 6" | 2 1/4" | 1 1/8" | IP67 | Extend, Retract | Belt Clip | 0000000 | 000000 |
3 | 8 | 12V DC | 50mA | 6" | 2 1/4" | 1 1/8" | IP67 | Extend, Retract | Belt Clip | 0000000 | 000000 |
Foot | |||||||||||
1 | 4 | 12V DC | 50mA | 1 1/2" | 9" | 4 1/8" | IP05 | Extend, Retract | __ | 0000000 | 000000 |

Material | Pkg. Qty. | Pkg. | |
Rubber | 2 | 0000000 | 00000 |
Precision Actuators for Stepper Motors


Accurately position a load by combining these actuators with a stepper motor, driver, and controller (all not included). Instead of just fully extending and retracting, these actuators precisely move loads to any point along the length of the stroke. And with a repeatability of ±0.01 mm, they'll move to the same spot on the stroke length every time. They’re often used in automated assemblies and other processes that require fine motion control. All are rated IP65 to withstand light rinses.
The extension rod is nonrotating, so it won’t twist as it extends and retracts. Thread accessories, such as clevis ends and ball joints, onto the rod end to attach your load.
Actuators for NEMA 23 motors mount from the motor body end to your mounting bracket with a clevis pin.
Actuators for NEMA 34 motors mount to a flat surface with the included base.
For technical drawings and 3-D models, click on a part number.
Dynamic Load Capacity, lbs. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Stroke Lg., mm | Pull | Push | Max. Speed, mm/s | Repeatability, mm | For Shaft Dia. | For Max. Motor Speed, rpm | For Max. Motor Torque, in.-oz. | Extension Rod Type | Environmental Rating | Retracted Lg. | Each | |
For NEMA 23 Motor Frame Size | ||||||||||||
100 | 719 | 719 | 1,000 | ±0.01 | 3/8" | 6,000 | 722 | Nonrotating | IP65 | 10 7/8" | 0000000 | 000000000 |
300 | 719 | 719 | 1,000 | ±0.01 | 3/8" | 6,000 | 722 | Nonrotating | IP65 | 18 3/4" | 0000000 | 00000000 |
500 | 719 | 719 | 1,000 | ±0.01 | 3/8" | 6,000 | 722 | Nonrotating | IP65 | 26 5/8" | 0000000 | 00000000 |
For NEMA 34 Motor Frame Size | ||||||||||||
100 | 719 | 719 | 1,000 | ±0.01 | 1/2" | 6,000 | 722 | Nonrotating | IP65 | 11 1/2" | 0000000 | 00000000 |
300 | 719 | 719 | 1,000 | ±0.01 | 1/2" | 6,000 | 722 | Nonrotating | IP65 | 19 3/8" | 0000000 | 00000000 |
500 | 719 | 719 | 1,000 | ±0.01 | 1/2" | 6,000 | 722 | Nonrotating | IP65 | 27 1/4" | 0000000 | 00000000 |