About Hazardous Location Environmental Ratings
More
About Electric Motors
When replacing a motor, use the information on your motor’s nameplate to guide your selection.
More
Hazardous Location Base-Mount AC Motors



These motors are rated for environments where hazardous material is present. They are continuous duty and mount horizontally. You can wire for clockwise or counterclockwise rotation; instructions are included. The base is welded to the enclosure.
Motors with automatic overload protection turn off in overload conditions to prevent motor damage and start automatically after they cool.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Lg. | Wd. | Ht. | Dia | Lg. | Center to Base | Shaft Type | Overload Protection Type | Class | Max. Temp, °F | Environmental Rating | Each | |
115/208/230 Volts AC, Single Phase | ||||||||||||||||
NEMA 48 | ||||||||||||||||
1/4 | 1,800 | 5.0/2.6/2.5 | No | 12 7/8" | 7 1/4" | 8 1/8" | 1/2" | 1 1/2" | 3" | D-Profile | Automatic | B | 104° | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 0000000 |
NEMA 56 | ||||||||||||||||
1/2 | 1,800 | 7.4/3.9/3.7 | No | 14 1/4" | 8 3/8" | 9 1/8" | 5/8" | 1 7/8" | 3 1/2" | Keyed | Automatic | B | 104° | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 000000 |
115/230 Volts AC, Single Phase | ||||||||||||||||
NEMA 56 | ||||||||||||||||
1 | 1,800 | 12.4/6.2 | No | 15 1/4" | 8 3/8" | 9 1/8" | 5/8" | 1 7/8" | 3 1/2" | Keyed | Automatic | B | 104° | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 00000000 |
208/230/460 Volts AC, Three Phase | ||||||||||||||||
NEMA 56 | ||||||||||||||||
3/4 | 1,800 | 3.2/3.0/1.5 | No | 14 1/4" | 8 3/8" | 9 1/8" | 5/8" | 1 7/8" | 3 1/2" | Keyed | Automatic | B | 104° | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 000000 |
230/460 Volts AC, Three Phase | ||||||||||||||||
NEMA 145T | ||||||||||||||||
2 | 1,800 | 5.4/2.7 | Yes | 15 1/4" | 8 5/8" | 9 1/8" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 104° | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 00000000 |
NEMA 56 | ||||||||||||||||
1 | 1,800 | 3.0/1.5 | Yes | 14 3/8" | 8 3/8" | 9 1/8" | 5/8" | 1 7/8" | 3 1/2" | Keyed | __ | F | 104° | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 00000000 |
Programmable Base/Face-Mount Speed-Control Motors
These speed-control motors combine a variable-frequency drive and motor into one, saving space in your control panel and reducing the amount of wiring required. Bolt them directly to gearboxes, pumps, and other machinery, or use the welded base to mount them to a surface. You can program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
The shaft is keyed and comes with key stock. These motors are rated for continuous duty, so they'll run equipment that never turns off. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled. A TEFC (totally enclosed fan cooled) motor enclosure protects these motors better than ODP (open dripproof) enclosures in damp and dusty environments. The external fan keeps the motor cool.
An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
Program these motors in a number of ways. You can download the free manufacturer software to your computer and connect to the motor via Bluetooth, or you can use a PC Connection Cord (sold separately) to connect your motor directly to your computer's USB port. The software allows you to control or monitor the motor in real time. To integrate them into larger control systems, these motors can be programmed using Modbus-RTU and BACnet protocols. Use a keypad (sold separately) to start or stop motors or to increase or decrease speed in real time. Its digital display also shows real-time motor information and allows you to edit control parameters. The keypad can be mounted up to 10 ft. away into a panel with the included cord to create a control station.
For technical drawings and 3-D models, click on a part number.



Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Environmental Rating | Each | |
120 Volts AC, Single Phase | ||||||||||||||
NEMA 143TC | ||||||||||||||
1 | 3,450 | 2.4 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/4" | 3 1/2" | F | 311° | IP54 | 0000000 | 000000000 |
240 Volts AC, Single Phase | ||||||||||||||
NEMA 143TC | ||||||||||||||
1 | 3,450 | 2.4 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/4" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 145TC | ||||||||||||||
2 | 3,450 | 4.4 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/4" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
240 Volts AC, Three Phase | ||||||||||||||
NEMA 143TC | ||||||||||||||
1 | 3,450 | 2.4 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/4" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 145TC | ||||||||||||||
2 | 3,450 | 4.3 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/4" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 182TC | ||||||||||||||
3 | 3,450 | 7.3 | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 10 5/8" | 14" | 1 1/8" | 2 3/4" | 4 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 184TC | ||||||||||||||
5 | 3,450 | 10.5 | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 10 5/8" | 14" | 1 1/8" | 2 3/4" | 4 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
460 Volts AC, Three Phase | ||||||||||||||
NEMA 184TC | ||||||||||||||
7 1/2 | 3,450 | 8.8 | Totally Enclosed Fan Cooled (TEFC) | 18 1/4" | 10 5/8" | 14" | 1 1/8" | 2 3/4" | 4 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 213TC | ||||||||||||||
7 1/2 | 3,000 | 8.6 | Totally Enclosed Fan Cooled (TEFC) | 18 1/8" | 10 3/4" | 15 5/8" | 1 3/8" | 3 3/8" | 5 1/4" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 215TC | ||||||||||||||
10 | 3,000 | 11 | Totally Enclosed Fan Cooled (TEFC) | 19 1/4" | 10 3/4" | 15 5/8" | 1 3/8" | 3 3/8" | 5 1/4" | F | 311° | IP54 | 0000000 | 00000000 |

USB Connection | RJ45 Connection | |||||||
---|---|---|---|---|---|---|---|---|
End Type | End Shape | Gender | End Type | End Shape | Gender | Serial Port Interface | Each | |
Plug | Straight | Male | Plug | Straight | Male | RS-485 | 0000000 | 0000000 |

Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Voltage Range | Current, mA | Ht. | Wd. | Dp. | Serial Port Interface | Reversing Capability | Environmental Rating | Specifications Met | Each | |
10V DC-36V DC | 30 | 3.19" | 2.6" | 0.95" | RS-485 | Reversing | IP54 | CE Marked | 0000000 | 0000000 |
Programmable Base-Mount Speed-Control Motors
Save space in your control panel with a variable-frequency drive and motor in one unit. These motors require less wiring than motors that need to be attached to a separate drive. They have a base mount that’s welded to the enclosure, so you can secure them to a flat surface. Program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
The shaft is keyed and comes with key stock. Rated for continuous duty, these motors can run machines that require constant power. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled. They also have totally enclosed fan cooled (TEFC) enclosures, which don’t have vents, so you can install them in damp and dirty environments. An external fan blows air over the outside of the enclosure to keep these motors cool.
An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
Download free software to control and monitor them in real time. Connect them to your computer via Bluetooth or use a PC connection cord (sold separately) to plug them into a USB port. To integrate them into larger control systems, these motors can be programmed using Modbus-RTU and BACnet protocols. Use a keypad (sold separately) to start or stop motors or to increase or decrease speed in real time. To create a control station, mount the keypad into a panel up to 10 ft. away from the motor with the included cord.
For technical drawings and 3-D models, click on a part number.



Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Environmental Rating | Each | |
120 Volts AC, Single Phase | ||||||||||||||
NEMA 143T | ||||||||||||||
1 | 3,450 | 2.3 | Totally Enclosed Fan Cooled (TEFC) | 12 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/2" | 3 1/2" | F | 311° | IP54 | 0000000 | 000000000 |
240 Volts AC, Single Phase | ||||||||||||||
NEMA 143T | ||||||||||||||
1 | 3,450 | 2.3 | Totally Enclosed Fan Cooled (TEFC) | 12 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/2" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 145T | ||||||||||||||
2 | 3,450 | 4.4 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/2" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
240 Volts AC, Three Phase | ||||||||||||||
NEMA 143T | ||||||||||||||
1 | 3,450 | 2.3 | Totally Enclosed Fan Cooled (TEFC) | 12 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/2" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 145T | ||||||||||||||
2 | 3,450 | 4.3 | Totally Enclosed Fan Cooled (TEFC) | 13 3/8" | 7 1/4" | 11 7/8" | 7/8" | 2 1/2" | 3 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 182T | ||||||||||||||
3 | 3,450 | 7.3 | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 10 5/8" | 14" | 1 1/4" | 3 1/2" | 4 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 184T | ||||||||||||||
5 | 3,450 | 10.5 | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 10 5/8" | 14" | 1 1/4" | 3 1/2" | 4 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
460 Volts AC, Three Phase | ||||||||||||||
NEMA 184T | ||||||||||||||
7 1/2 | 3,450 | 8.8 | Totally Enclosed Fan Cooled (TEFC) | 18 1/4" | 10 5/8" | 14" | 1 1/4" | 3 1/2" | 4 1/2" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 213T | ||||||||||||||
7 1/2 | 3,000 | 8.6 | Totally Enclosed Fan Cooled (TEFC) | 18 1/8" | 10 3/4" | 15 5/8" | 1 3/8" | 3 7/8" | 5 1/4" | F | 311° | IP54 | 0000000 | 00000000 |
NEMA 215T | ||||||||||||||
10 | 3,000 | 11 | Totally Enclosed Fan Cooled (TEFC) | 19 1/4" | 10 3/4" | 15 5/8" | 1 3/8" | 3 7/8" | 5 1/4" | F | 311° | IP54 | 0000000 | 00000000 |

USB Connection | RJ45 Connection | |||||||
---|---|---|---|---|---|---|---|---|
End Type | End Shape | Gender | End Type | End Shape | Gender | Serial Port Interface | Each | |
Plug | Straight | Male | Plug | Straight | Male | RS-485 | 0000000 | 0000000 |

Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Voltage Range | Current, mA | Ht. | Wd. | Dp. | Serial Port Interface | Reversing Capability | Environmental Rating | Specifications Met | Each | |
10V DC-36V DC | 30 | 3.19" | 2.6" | 0.95" | RS-485 | Reversing | IP54 | CE Marked | 0000000 | 0000000 |
Programmable Face-Mount Speed-Control Motors
A variable-frequency drive and motor in one unit, these motors save space in your control panel and require less wiring than separate drives and motors. They bolt directly to gearboxes, pumps, and other machinery. You can program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
Rated for continuous duty, these motors can run machines that require constant power. They have totally enclosed fan cooled (TEFC) enclosures, which don’t have vents, so you can install them in damp and dirty environments. An external fan blows air over the outside of the enclosure to keep these motors cool. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled.
An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
Download free software to control and monitor them in real time. Connect them to your computer via Bluetooth or use a PC connection cord (sold separately) to plug them into a USB port. These motors also use Modbus-RTU and BACnet protocols, so you can integrate them into building and process control systems. You can also use a keypad (sold separately) to control these motors. It has a digital display that shows live motor information, such as output frequency and speed, and allows you to edit control parameters in real time. To create a control station, mount the keypad into a panel up to 10 ft. away from the motor with the included cord.
For technical drawings and 3-D models, click on a part number.



Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Environmental Rating | Each | |
120 Volts AC, Single Phase | ||||||||||||||
NEMA 143TC | ||||||||||||||
1 | 3,450 | 2.4 | Totally Enclosed Fan Cooled (TEFC) | 12 3/8" | 7 1/4" | 11 5/8" | 7/8" | 2 1/4" | 3.14" | F | 311° | IP54 | 00000000 | 000000000 |
240 Volts AC, Single Phase | ||||||||||||||
NEMA 143TC | ||||||||||||||
1 | 3,450 | 2.4 | Totally Enclosed Fan Cooled (TEFC) | 12 3/8" | 7 1/4" | 11 5/8" | 7/8" | 2 1/4" | 3.14" | F | 311° | IP54 | 00000000 | 00000000 |
NEMA 145TC | ||||||||||||||
2 | 3,450 | 4.4 | Totally Enclosed Fan Cooled (TEFC) | 13 5/8" | 7 1/4" | 11 5/8" | 7/8" | 2 1/4" | 3.14" | F | 311° | IP54 | 00000000 | 00000000 |
240 Volts AC, Three Phase | ||||||||||||||
NEMA 143TC | ||||||||||||||
1 | 3,450 | 2.4 | Totally Enclosed Fan Cooled (TEFC) | 12 3/8" | 7 1/4" | 11 5/8" | 7/8" | 2 1/4" | 3.14" | F | 311° | IP54 | 00000000 | 00000000 |
NEMA 145TC | ||||||||||||||
2 | 3,450 | 4.3 | Totally Enclosed Fan Cooled (TEFC) | 13 5/8" | 7 1/4" | 11 5/8" | 7/8" | 2 1/4" | 3.14" | F | 311° | IP54 | 00000000 | 00000000 |
NEMA 182TC | ||||||||||||||
3 | 3,450 | 7.3 | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 10 5/8" | 13 3/4" | 1 1/8" | 2 3/4" | 4.37" | F | 311° | IP54 | 00000000 | 00000000 |
NEMA 184TC | ||||||||||||||
5 | 3,450 | 10.5 | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 10 5/8" | 13 3/4" | 1 1/8" | 2 3/4" | 4.37" | F | 311° | IP54 | 00000000 | 00000000 |
460 Volts AC, Three Phase | ||||||||||||||
NEMA 184TC | ||||||||||||||
7 1/2 | 3,450 | 8.8 | Totally Enclosed Fan Cooled (TEFC) | 18 1/4" | 10 5/8" | 13 3/4" | 1 1/8" | 2 3/4" | 4.37" | F | 311° | IP54 | 00000000 | 00000000 |
NEMA 213TC | ||||||||||||||
7 1/2 | 3,000 | 8.6 | Totally Enclosed Fan Cooled (TEFC) | 18 1/8" | 10 3/4" | 15 3/8" | 1 3/8" | 3 3/8" | 4.67" | F | 311° | IP54 | 00000000 | 00000000 |
NEMA 215TC | ||||||||||||||
10 | 3,000 | 11 | Totally Enclosed Fan Cooled (TEFC) | 19 1/4" | 10 3/4" | 15 3/8" | 1 3/8" | 3 3/8" | 4.67" | F | 311° | IP54 | 00000000 | 00000000 |

USB Connection | RJ45 Connection | |||||||
---|---|---|---|---|---|---|---|---|
End Type | End Shape | Gender | End Type | End Shape | Gender | Serial Port Interface | Each | |
Plug | Straight | Male | Plug | Straight | Male | RS-485 | 0000000 | 0000000 |

Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Voltage Range | Current, mA | Ht. | Wd. | Dp. | Serial Port Interface | Reversing Capability | Environmental Rating | Specifications Met | Each | |
10V DC-36V DC | 30 | 3.19" | 2.6" | 0.95" | RS-485 | Reversing | IP54 | CE Marked | 0000000 | 0000000 |
AC Gearmotors

Turn speed into torque with these AC-powered gearmotors—they combine a motor and a speed reducer into one. You can wire them for clockwise or counterclockwise rotation; instructions are included. The parallel shaft transmits motion inline with the motor.
Base/face-mount motors give you the flexibility to mount directly onto equipment or to the included base.
TEFC (totally enclosed fan cooled) motors have an enclosure to protect them from dirt, dust, and moisture. An external fan blows air on the enclosure to keep them cool.
For technical drawings and 3-D models, click on a part number.


Overall | Shaft | Insulation | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Gear Type | Bearing Type | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
115/230 Volts AC, Single Phase | |||||||||||||||||
1/4 | 47 rpm @ 294 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 0000000 |
1/4 | 88 rpm @ 163 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |
1/4 | 113 rpm @ 128 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |
1/4 | 159 rpm @ 91 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |