    26 Products

    Base-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Motors.
    To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures don’t have vents, so they can be used in wet and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 182T
    33,4907.0 amp/3.5 ampYesTotally Enclosed Fan-Cooled (TEFC)14 3/4"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N610000000
     
    NEMA 184T
    53,48011.4 amp/5.7 ampYesTotally Enclosed Fan-Cooled (TEFC)15 3/4"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N63000000
     
    NEMA 213T
    31,1758.0 amp/4.0 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/8"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N62000000
    7 1/23,51017.3 amp/8.6 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/8"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N65000000
     
    NEMA 215T
    51,17012.4 amp/6.2 ampYesTotally Enclosed Fan-Cooled (TEFC)19 5/8"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N6400000000
    103,51023.0 amp/11.5 ampYesTotally Enclosed Fan-Cooled (TEFC)19 5/8"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N67000000
     
    NEMA 254T
    7 1/21,17019.1 amp/9.5 ampYesTotally Enclosed Fan-Cooled (TEFC)23 5/8"17 5/8"14 3/4"1 5/8"4"6 1/4"KeyedWeldedF3117014N6600000000
    151,76534.5 amp/17.3 ampYesTotally Enclosed Fan-Cooled (TEFC)23 5/8"17 5/8"14 3/4"1 5/8"4"6 1/4"KeyedWeldedF3117014N6900000000
     
    NEMA 256T
    101,17025.6 amp/12.8 ampYesTotally Enclosed Fan-Cooled (TEFC)25 3/8"17 5/8"14 3/4"1 5/8"4"6 1/4"KeyedWeldedF3117014N6800000000
    201,76046.0 amp/23.0 ampYesTotally Enclosed Fan-Cooled (TEFC)25 3/8"17 5/8"14 3/4"1 5/8"4"6 1/4"KeyedWeldedF3117014N7200000000
     
    NEMA 284T
    151,17536.4 amp/18.2 ampYesTotally Enclosed Fan-Cooled (TEFC)26 3/4"20 1/4"16 7/8"1 7/8"4 5/8"7"KeyedWeldedF3117014N7100000000
    251,76558.2 amp/29.1 ampYesTotally Enclosed Fan-Cooled (TEFC)26 3/4"20 1/4"16 7/8"1 7/8"4 5/8"7"KeyedWeldedF3117014N7400000000
     
    NEMA 286T
    201,17048.6 amp/24.3 ampYesTotally Enclosed Fan-Cooled (TEFC)28 1/4"20 1/4"16 7/8"1 7/8"4 5/8"7"KeyedWeldedF3117014N7300000000
     
    NEMA 324T
    251,17060.6 amp/30.3 ampYesTotally Enclosed Fan-Cooled (TEFC)29 1/2"22 3/8"18 3/4"2 1/8"5 1/4"8"KeyedWeldedF3117014N7500000000
     

    Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Face-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Face-Mount AC Motors.
    Bolt these motors directly to gearboxes, pumps, and other machinery. They’re more compact than base-mount motors and the direct, rigid connection to your equipment helps keep them aligned. Rated for continuous duty, they are often used with equipment that requires constant power, such as fans and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Inverter Rated—These motors are inverter-rated, so you can use them with a variable frequency drive (AC motor speed control).
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—A totally enclosed fan-cooled (TEFC) enclosure means you can use them in wet and dirty environments since they don’t have vents. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 184TC
    51,74512.2 amp/6.1 ampYesTotally Enclosed Fan-Cooled (TEFC)17 5/8"12"11 3/4"1 1/8"2 3/4"4 1/2"KeyedF3117015N660000000
    53,48011.4 amp/5.7 ampYesTotally Enclosed Fan-Cooled (TEFC)17 5/8"12"11 3/4"1 1/8"2 3/4"4 1/2"KeyedF3117015N65000000
     
    NEMA 213TC
    7 1/21,75517.7 amp/8.8 ampYesTotally Enclosed Fan-Cooled (TEFC)20"13 3/8"13 1/4"1 3/8"3 3/8"4 1/2"KeyedF3117015N68000000
    7 1/23,51017.3 amp/8.6 ampYesTotally Enclosed Fan-Cooled (TEFC)20"13 3/8"13 1/4"1 3/8"3 3/8"4 1/2"KeyedF3117015N67000000
     
    NEMA 215TC
    101,75523.3 amp/11.6 ampYesTotally Enclosed Fan-Cooled (TEFC)21 1/2"13 3/8"13 1/4"1 3/8"3 3/8"4 1/2"KeyedF3117015N7100000000
    103,51023.0 amp/11.5 ampYesTotally Enclosed Fan-Cooled (TEFC)20"13 3/8"13 1/4"1 3/8"3 3/8"4 1/2"KeyedF3117015N69000000
     

    Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount AC Motors.
    Whether you’re switching between jobs or need flexibility during installation, these motors give you a variety of mounting options. Fix the feet to a flat surface or bolt the face directly to a gearbox, pump, or other machinery. You can also do both at once for added stability in applications with high loads or vibration. These motors are rated for continuous duty, so they’re often used for equipment that requires constant power, such as fans, pumps, and conveyors.
    These motors have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—A totally enclosed fan-cooled (TEFC) enclosure means you can use them in wet and dirty environments since they don’t have vents. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Inverter Rated—These motors are also inverter-rated, so you can use them with a variable frequency drive (AC motor speed control).
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 184TC
    51,74512.2 amp/6.1 ampYesTotally Enclosed Fan-Cooled (TEFC)15 7/8"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117026N1080000000
    53,48011.4 amp/5.7 ampYesTotally Enclosed Fan-Cooled (TEFC)15 7/8"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117026N107000000
     
    NEMA 213TC
    7 1/21,75517.7 amp/8.8 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/8"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117026N111000000
    7 1/23,51017.3 amp/8.6 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/8"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117026N109000000
     
    NEMA 215TC
    101,76524.6 amp/12.3 ampYesTotally Enclosed Fan-Cooled (TEFC)19 1/2"14 1/4"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117026N113000000
    103,51023.0 amp/11.5 ampYesTotally Enclosed Fan-Cooled (TEFC)19 1/2"14 3/8"12 1/4"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117026N112000000
     