    US-Made Base-Mount AC Motors

    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.
    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.

    Motor with Open Enclosure

    Motor with Totally

    Enclosed Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Wound, wired, and assembled in the U.S. These base-mount motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Rated for continuous duty, they’re often used with equipment that requires constant power, such as fans, pumps, and conveyors. Bolt the base of these motors to any flat surface and connect the shaft to your load.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures only have vents.
    Open Slotted Band (OPSB) Motor Enclosure—Open slotted band (OPSB) enclosures only have vents.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Manual—Manual overload protection must be reset manually to start the motor after it cools.
    Overload Protection Type—Motors with overload protection turn off in overload conditions to prevent motor damage.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    115V AC/208V AC/230V AC, Single Phase
     
    NEMA 145T
    1 1/21,72521.0 amp/9.6 amp/10.5 ampNoOpen Dripproof (ODP)14 1/4"10 1/4"9"7/8"2 1/4"3 1/2"KeyedWeldedManualB2665990K1090000000005990K4030000000
    1 1/21,75514.0 amp/7.3 amp/7.0 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/8"9 1/2"9 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K1250000005990K404000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 145T
    1 1/21,7554.4 amp/2.2 ampYesOpen Slotted Band (OPSB)11 3/4"9"7 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K3030000005990K403000000
    1 1/21,7604.4 amp/2.2 ampYesTotally Enclosed Fan-Cooled (TEFC)13 1/2"9 1/2"7 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K3070000005990K404000000
    21,7505.8 amp/2.9 ampYesOpen Slotted Band (OPSB)12 1/4"9"7 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K3040000005990K403000000
    21,7555.8 amp/2.9 ampYesTotally Enclosed Fan-Cooled (TEFC)14 1/4"9 1/2"7 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K3080000005990K404000000
    33,4507.6 amp/3.8 ampYesOpen Slotted Band (OPSB)13"9"7 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K3050000005990K403000000
     

    Base-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Motors.
    To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures don’t have vents, so they can be used in wet and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Automatic—Motors with automatic overload protection turn off in overload conditions to prevent damage. Once they cool down, they start again automatically.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    115V AC/230V AC, Single Phase
     
    NEMA 145T
    1 1/21,74012.8 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/8"8 3/4"8 1/4"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticF3117014N190000000
     
    NEMA 143T/NEMA 145T
    1 1/21,74011.9 amp/5.9 ampNoOpen Dripproof (ODP)15 1/4"8 1/2"8 1/4"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticF3117014N17000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 143T/NEMA 145T
    1 1/21,7504.0 amp/2.0 ampYesOpen Dripproof (ODP)12 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N16000000
    1 1/21,7504.0 amp/2.0 ampYesTotally Enclosed Fan-Cooled (TEFC)14 1/8"9 7/8"7 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N21000000
    21,7405.2 amp/2.7 ampYesTotally Enclosed Fan-Cooled (TEFC)14 1/8"9 7/8"7 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N22000000
    21,7405.4 amp/2.7 ampYesOpen Dripproof (ODP)12 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N15000000
    33,5057.6 amp/3.8 ampYesOpen Dripproof (ODP)12 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N18000000
     

    Hazardous Location Base-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Hazardous Location Base-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Base-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Base-Mount AC Motors.
    These motors are rated for environments where hazardous material is present. They are continuous duty and mount horizontally. You can wire for clockwise or counterclockwise rotation; instructions are included. The base is welded to the enclosure.
    Hazardous Location Rating—Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Hazardous Location Rating
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145T
    21,8005.4 amp/2.7 ampYesTotally Enclosed Fan-Cooled (TEFC)15 1/4"8 5/8"9 1/8"7/8"2 1/4"3 1/2"KeyedWeldedF104NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    4980N26000000000
     

    Base-Mount AC Brake Motors

    Image of Product. Front orientation. Electric Motors. Base-Mount AC Brake Motors.
    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Brake Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Brake Motors.
    Unlike standard AC motors, these motors have an integrated brake that activates after a power loss to hold your equipment in place. They’re often used with conveyors to stop them from moving backwards after a power loss, and with hoists to prevent them from dropping a load. Mount their base to flat surfaces. Rated for continuous duty, these motors can run equipment that never turns off. Their shaft is keyed, and they come with key stock.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—These motors have a TEFC (totally enclosed fan-cooled) enclosure that protects better than an ODP (open dripproof) enclosure. They aren’t airtight, but they can be used in dirty, dusty, and wet environments. To keep the motor cool, the enclosure has an external fan that blows air over the outside of the motor.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    230V AC/460V AC, Three Phase
     
    NEMA 145T
    1 1/21,7504.4 amp/2.2 ampNoTotally Enclosed Fan-Cooled (TEFC)18 1/8"9 1/8"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedB266IP43
    4952N13000000000
     

    Programmable Base-Mount Speed-Control Motors

    Image of Product. Front orientation. Electric Motors. Programmable Base-Mount Speed-Control Motors.
    Image of Attribute. Front orientation. Contains Annotated. Programmable Base-Mount Speed-Control Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Programmable Base-Mount Speed-Control Motors.
    Save space in your control panel with a variable-frequency drive and motor in one unit. These motors require less wiring than motors that need to be attached to a separate drive. They have a base mount that’s welded to the enclosure, so you can secure them to a flat surface. Program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
    The shaft is keyed and comes with key stock. Rated for continuous duty, these motors can run machines that require constant power. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled.
    An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
    Download free software to control and monitor them in real time. Connect them to your computer via Bluetooth or use a PC connection cord to plug them into a USB port. To integrate them into larger control systems, these motors can be programmed using Modbus-RTU and BACnet protocols.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—These motors also have totally enclosed fan-cooled (TEFC) enclosures, which don’t have vents, so you can install them in damp and dirty environments. An external fan blows air over the outside of the enclosure to keep these motors cool.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Component
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    230V AC, Three Phase
     
    NEMA 145T
    23,4504.3 ampYesTotally Enclosed Fan-Cooled (TEFC)13 3/8"7 1/4"11 7/8"7/8"2 1/2"3 1/2"KeyedWeldedAutomaticController, MotorF311IP54
    7124N15000000000
    23,4504.4 ampYesTotally Enclosed Fan-Cooled (TEFC)13 3/8"7 1/4"11 7/8"7/8"2 1/2"3 1/2"KeyedWeldedAutomaticController, MotorF311IP54
    7124N1300000000
     
    Accessories for Electric Motors