    25 Products

    Base-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Motors.
    To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures don’t have vents, so they can be used in wet and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Automatic—Motors with automatic overload protection turn off in overload conditions to prevent damage. Once they cool down, they start again automatically.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    115V AC/230V AC, Single Phase
     
    NEMA 56H
    3/41,7506.5 amp/3.3 ampNoOpen Dripproof (ODP)12 3/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N350000000
    1 1/21,74012.8 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/4"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N57000000
    1 1/23,50012.2 amp/6.1 ampNoOpen Dripproof (ODP)13 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N58000000
     
    NEMA 56/NEMA 56H
    11,7409.1 amp/4.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N54000000
    11,7508.8 amp/4.4 ampNoOpen Dripproof (ODP)13 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N29000000
    13,5009.0 amp/4.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N55000000
    1 1/23,50012.2 amp/6.1 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/4"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N53000000
    21,74016.1 amp/8.0 ampNoOpen Dripproof (ODP)15 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N52000000
    23,50016.4 amp/8.2 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/4"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N56000000
     

    US-Made Base-Mount AC Motors

    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.
    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.

    Motor with Open Enclosure

    Motor with Totally

    Enclosed Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Wound, wired, and assembled in the U.S. These base-mount motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Rated for continuous duty, they’re often used with equipment that requires constant power, such as fans, pumps, and conveyors. Bolt the base of these motors to any flat surface and connect the shaft to your load.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures only have vents.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Vibration-Damping Base—Motors with a vibration-damping base have rubber rings between the base and enclosure to minimize vibration.
    Automatic—Automatic overload protection starts the motor automatically after it cools.
    Manual—Manual overload protection must be reset manually to start the motor after it cools.
    Overload Protection Type—Motors with overload protection turn off in overload conditions to prevent motor damage.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    115V AC/230V AC, Single Phase
     
    NEMA 56H
    1 1/21,72512.2 amp/6.1 ampNoTotally Enclosed Fan-Cooled (TEFC)14"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K8100000005990K4040000000
    1 1/21,72512.4 amp/6.2 ampNoOpen Dripproof (ODP)14"9 3/4"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K153000000005990K403000000
    1 1/23,48011.8 amp/5.9 ampNoOpen Dripproof (ODP)12 3/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1420000005990K403000000
     
    NEMA 56/NEMA 56H
    3/41,1407.8 amp/4.2 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K74000000005990K404000000
    11,72512.5 amp/6.3 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K760000005990K404000000
    11,72513.0 amp/6.5 ampNoOpen Dripproof (ODP)11 1/2"7"9"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K310000005990K403000000
    11,72513.0 amp/6.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"10"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3115990K990000005990K404000000
    13,45011.8 amp/5.9 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K750000005990K404000000
    13,45012.0 amp/6.0 ampNoTotally Enclosed Fan-Cooled (TEFC)13"10"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedManualB2665990K1010000005990K404000000
    1 1/23,45016.0 amp/8.0 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K790000005990K404000000
    23,45023.0 amp/11.5 ampNoTotally Enclosed Fan-Cooled (TEFC)14"10"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedManualB2665990K102000000005990K404000000
    23,47015.6 amp/7.8 ampNoOpen Dripproof (ODP)14"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1410000005990K403000000
     
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56H
    3/41,1403.3 amp/3.0 amp/1.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"8 1/2"6 3/4"5/8"1 7/8"3 1/2"KeyedWeldedB2666136K760000005990K402000000
     
    back to top