USB Adapter Cords
Adapt your USB port to connect to a variety of other devices. These USB cords are backward compatible, so they work with cords and connectors that meet the same or a lower USB standard.
Double-shielded cords have insulation, so they reduce signal interference from nearby equipment and devices.
Cords with USB-C power delivery have a port to power or charge an additional device.

Length, ft. | Application | Ethernet Cable Category | Shielding | Color | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | ||||||
---|---|---|---|---|---|---|
1 | Data | 6 | Unshielded | Silver | 0000000 | 000000 |

Length | Application | Ethernet Cable Category | Shielding | Shield Type | Color | Features | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | ||||||||
---|---|---|---|---|---|---|---|---|
4 1/2" | Data/Power | 6 | Double Shielded | Braid, Foil | White | USB-C Power Delivery 3.0 | 0000000 | 000000 |
Panel-Mount Ethernet Adapters

Mount these adapters in a panel cutout. They have an RJ45 female connection on both ends to join two Ethernet cords.
Shielded adapters protect equipment from electromagnetic interference. Those that screw in don’t require additional drilled holes or fasteners to mount. They need a more precise panel cutout than adapters that screw on.
Choose unshielded adapters when signal interference isn’t a concern.
Zinc adapters are more durable than plastic adapters.
Add a cap to protect these adapters when not in use. Hinged caps open and shut quickly at a fixed angle, so they’re more convenient for frequent access than tethered caps. Tethered caps can open in any direction, letting you access adapters from any angle. IP40-rated caps have a locking mechanism for extra security.
Label holders (sold separately) snap onto the front of adapters.




0.14" Diameter Mounting Holes | Metric Threaded Mounting Holes | UNC Threaded Mounting Holes | |||||||
---|---|---|---|---|---|---|---|---|---|
For Cable Industry Designation | For Panel Cutout Dia. | Mounting Fasteners Included | Color | Each | Each | Each | |||
RJ45 Female × RJ45 Female | |||||||||
Plastic Housing | |||||||||
Category 5E | 0.95" | Yes | Black | 0000000 | 000000 | 000000 | 00 | 000000 | 00 |
Category 6 | 0.95" | Yes | Black | 0000000 | 00000 | 000000 | 00 | 000000 | 00 |
Category 6A | 0.95" | Yes | Black | 0000000 | 00000 | 000000 | 00 | 000000 | 00 |
Zinc Housing | |||||||||
Category 5E | 0.95" | Yes | Black | 0000000 | 00000 | 0000000 | 000000 | 0000000 | 000000 |
Category 6 | 0.95" | Yes | Black | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Category 6A | 0.95" | Yes | Black | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |


0.14" Diameter Mounting Holes | Metric Threaded Mounting Holes | UNC Threaded Mounting Holes | |||||||
---|---|---|---|---|---|---|---|---|---|
For Cable Industry Designation | For Panel Cutout Dia. | Mounting Fasteners Included | Color | Each | Each | Each | |||
RJ45 Female × RJ45 Female | |||||||||
Plastic Housing | |||||||||
Category 5E | 0.95" | Yes | Black | 0000000 | 000000 | 000000 | 00 | 000000 | 00 |
Category 6 | 0.95" | Yes | Black | 0000000 | 00000 | 000000 | 00 | 000000 | 00 |
Category 6A | 0.95" | Yes | Black | 0000000 | 00000 | 000000 | 00 | 000000 | 00 |
Zinc Housing | |||||||||
Category 5E | 0.95" | Yes | Black | 0000000 | 00000 | 0000000 | 000000 | 0000000 | 000000 |
Category 6 | 0.95" | Yes | Black | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Category 6A | 0.95" | Yes | Black | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
For Panel Cutout Diameter | Cap Type | Material | Seal Material | Flexibility | Color | Environmental Rating | Each | |
Hinged | ||||||||
---|---|---|---|---|---|---|---|---|
0.88" | Snap On | Plastic | Buna-N Rubber | Rigid | Black | IP65, IP67 | 0000000 | 000000 |
0.88" | Snap On | Plastic | Buna-N Rubber | Rigid | Clear | IP40 | 0000000 | 00000 |
0.88" | Snap On | Plastic | Buna-N Rubber | Rigid | Clear | IP65, IP67 | 0000000 | 00000 |
Tethered | ||||||||
0.88" | Snap On | Rubber | __ | Flexible | Black | IP65, IP67 | 000000 | 0000 |
0.95" | Snap On | Rubber | __ | Flexible | Black | __ | 0000000 | 0000 |
Shielded Data Adapters

Protect sensitive equipment from electromagnetic interference. These adapters have an RJ45 female connection on both ends to join two Ethernet cords.
Data Adapters for Keystone Wall Plates

Create various configurations by snapping these adapters into the ports of keystone wall plates. They have an RJ45 female connection on both ends to join two Ethernet cords.
For Cable Industry Designation | Number of Wires | Color | Housing Material | Specifications Met | Each | |
RJ45 Female × RJ45 Female | ||||||
---|---|---|---|---|---|---|
Category 5E | 8 | Black | Plastic | UL Listed, C-UL Listed | 000000 | 000000 |
Category 5E | 8 | White | Plastic | UL Listed, C-UL Listed | 000000 | 00000 |
Category 6 | 8 | __ | Tin | UL Listed, C-UL Listed | 0000000 | 00000 |
Category 6 | 8 | Black | Plastic | UL Listed, C-UL Listed | 000000 | 00000 |
Category 6 | 8 | White | Plastic | UL Listed, C-UL Listed | 000000 | 00000 |
USB Extenders


Increase the reach of USB devices. Connect the transmitter and receiver with an Ethernet cord (sold separately), minimizing signal loss over long runs. USB ports are backward compatible, so they work with cords and connectors that meet the same or a lower USB standard.
Receiver | Transmitter | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
USB Connection Type (No. of Connections) | Ethernet Connection Type | Max. Transmission Distance, ft. | USB Connection Type | Ethernet Connection Type | USB Standard | Transmission Speed, Mbps | Cord Lg. | Color | Housing Material | Includes | Each | |
Type A Female (1) | RJ45 Female | 150 | Type A Male | RJ45 Female | 1.1 | 12 | 12" | Black | Plastic | __ | 000000 | 000000 |
Type A Female (1) | RJ45 Female | 160 | Type A Male | RJ45 Female | 2.0 | 480 | 6" | Black | Plastic | 120V AC Adapter | 000000 | 000000 |
Type A Female (4) | RJ45 Female | 160 | Type A Male | RJ45 Female | 2.0 | 480 | 6" | Black | Plastic | 120V AC Adapter | 000000 | 000000 |
Micro M12 Screw-Together Ethernet Connectors
Unlike traditional RJ45 connectors found in data centers, these connectors stand up to rugged industrial environments since they tightly thread to devices with M12 connections, sealing out contaminants and resisting shaking loose from vibration. Use them to transfer high-speed data between sensors, switches, computers, IO modules, programmable logic controllers (PLCs), and other equipment. They can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. These connectors are often used with EtherNet/IP, Profinet, and EtherCAT systems. Since they’re shielded, they block signal interference from nearby devices, maintaining their speed and data integrity. Poles and keyways on the face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
A-coded and X-coded connectors send data faster than D-coded connectors, so they’re best for robotics and other systems that run multi-step programs.
Adapters create a transition point between an M12 and RJ45 connection. Use them in panels or walls—your tough threaded connection on one side and your control panel and computer or PLC on the other.
90° elbow connectors run your cord along the side of equipment, so they fit behind machines and in tight spaces.
IP rated connectors keep out dust and can be used in wet areas when mated or capped. IP65 connectors can be lightly rinsed. IP67 connectors can be submerged temporarily.
Add caps to protect connectors and maintain their IP ratings when not in use.






Housing Thread | Mounting Thread | Environmental Rating | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Shielding | For Cable Industry Designation | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Size | Pitch, mm | Temperature Range, °F | M12 Connection | RJ45 Connection | Each | |
A-Code Female × RJ45 Female | |||||||||||||||
8 | Shielded | Category 5E | 10 Gb/s | Silver | Plastic | M12 | 1 | 0.48" | M12 | 1 | -40° to 175° | IP67 | IP67 | 0000000 | 000000 |
D-Code Female × RJ45 Female | |||||||||||||||
4 | Shielded | Category 5 | 100 Mbps | Silver | Plastic | M12 | 1 | 0.66" | M16 | 1.5 | -40° to 185° | IP65, IP67 | IP20 | 000000 | 00000 |
X-Code Female × RJ45 Female | |||||||||||||||
8 | Shielded | Category 5E, Category 6, Category 6A | 10 Gb/s | __ | Zinc | M12 | 1 | 0.88" | M16 | 1.5 | -10° to 185° | IP67 | IP20 | 0000000 | 00000 |




Housing Thread | Mounting Thread | Environmental Rating | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Shielding | For Cable Industry Designation | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Size | Pitch, mm | Temperature Range, °F | M12 Connection | RJ45 Connection | Each | |
D-Code Female × RJ45 Female | |||||||||||||||
4 | Shielded | Category 5 | 100 Mbps | Black | Plastic | M12 | 1 | 0.66" | M16 | 1.5 | -40° to 185° | IP65, IP67 | IP20 | 000000 | 000000 |
X-Code Female × RJ45 Female | |||||||||||||||
8 | Shielded | Category 5E, Category 6, Category 6A | 10 Gb/s | __ | Zinc | M12 | 1 | 0.88" | M16 | 1.5 | -10° to 185° | IP67 | IP20 | 0000000 | 00000 |

For Thread Size | Material | Each | |
For Sockets, Receptacles, and Adapters with Internal Threads | |||
---|---|---|---|
M12 | Anodized Aluminum | 0000000 | 000000 |
Screw-Together Wet-Location RJ45 Connectors and Cords
Use these connectors and cords to make Ethernet connections.
IP67 rated connectors and cords are protected against dust and temporary submersion when mated.
Shielded adapters prevent electromagnetic interference (EMI) to minimize signal distortion.

For Panel Cutout Dia. | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | |||||||||
---|---|---|---|---|---|---|---|---|---|
40mm | Category 5E | 100 MHz | 8 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |

Ethernet Connection Type | For Panel Cutout Dia. | Shield Type | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Shielded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
RJ45 | 1" | Foil | Category 5E | 100 MHz | 8 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |
Latching Washdown RJ45 Connectors
Protect connections in washdown environments while maintaining access—these RJ45 plugs and adapters latch together securely, yet quickly detach. When mated, they’re rated IP65 and IP67 for protection against washdowns and temporary submersion. All are shielded to prevent electromagnetic interference.
Plugs have a snap-on wire connection that pierces the insulation to eliminate the need for wire stripping.
Adapters have an attached cover to maintain the IP67 rating when not in use.

For Cable Industry Designation | Wire Connection Type | Number of Wires | For Cable OD | Housing Material | Color | Environmental Rating | Specifications Met | Each | |
Shielded | |||||||||
---|---|---|---|---|---|---|---|---|---|
Category 5E | Snap On | 8 | 0.26"-0.37" | Powder-Coated Zinc | Gray | IP65, IP67 | DNV-GL Type Approved | 000000 | 000000 |

For Cable Industry Designation | Number of Wires | Housing Material | Color | Number of Latching Levers | Mounting Location | For Panel Cutout Dia. | Environmental Rating | Specifications Met | Each | |
Shielded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Category 5E | 8 | Powder-Coated Zinc | Gray | 1 | Panel | 0.88" | IP65, IP67 | DNV-GL Type Approved | 000000 | 000000 |
Status-Indicating DIN-Rail Power Supplies

Monitor voltage, current, remaining life, and other maintenance data from your PC, PLC, or by glancing at the digital display. There's no need to inspect these power supplies with multimeters or other test equipment. They also connect to your network, so you can view and analyze data remotely. Like other power supplies, they convert AC to DC voltage to power electronic equipment. Mount these power supplies onto DIN rails, which are commonly found inside industrial cabinets and electrical panels. All have spring-clamp wire terminals for quick connections that hold firmer than screw-style terminals.
Download the free software to view readings, save historical data, and analyze performance over time. Having all of your data in one place means you can troubleshoot and create predictive maintenance plans without needing to walk the floor and open enclosures to perform inspections. Saving historical data reduces maintenance costs because you can better predict when equipment should be replaced. Set alarm conditions, so you're alerted if a particular reading is too high or low. All power supplies are compatible with common Ethernet communication standards—check on them from anywhere without additional measuring equipment or sensors.
All of these power supplies use switching regulation, which means they produce the stated voltage despite fluctuations in your input power and the power being drawn by your system, and they won’t become too hot. They’re also SEMI F47 compliant, so they meet standards for maintaining output voltage when input voltage dips. This is commonly known as voltage sag immunity.
If you exceed the maximum voltage, temperature, or load, these power supplies protect both the power supply and the connected equipment. They also meet the voltage requirements for use in a PELV (protected extra low voltage) circuit.
Rated IP20, these power supplies prevent your fingers from touching internal components and accidentally shocking yourself. They're UL and C-UL Listed, TUV Rheinland Certified, and CE Marked so you know they meet stringent safety standards. With an NEC Class 2 and LPS output, if something fails inside the power supply, these limit the risk of electrical shock.
Maximum output noise is also known as ripple noise. The lower the value, the less interference the power supply creates. For most applications, a value over 100mVpp isn’t a problem. However, when using to power extremely sensitive electronics, such as audio equipment and high-precision measuring and testing equipment, you’ll want an output noise around 5mVpp or less.
Power factor shows how effectively a power supply draws AC power from the main electrical supply. The higher the power factor—up to a maximum score of 1—the lower your operating cost.
Efficiency describes how good a power supply is at converting the AC power it draws from your main electrical supply into DC power. High-efficiency power supplies cost less money to operate and produce less heat, meaning cooler temperatures in your electrical cabinet.
Power supplies with an output peak current briefly boost power above their maximum operating current for starting motors, actuating solenoid valves, and other applications that require a higher starting current than their operating current.
Output | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage (Adjustment Range) | Current, A | Peak Current | Power, W | Max. Output Noise Peak-to-Peak, mV DC | Power Factor | Efficiency | Max. Transmission Distance, ft. | Ht. | Wd. | Dp. | Specifications Met | Each | |
Single Phase—100-240V AC Input Voltage | |||||||||||||
Spring-Clamp Terminals Input and Output | |||||||||||||
24V DC (21.6-28V DC) | 5 | 6 A, 3 seconds | 120 | 150 | 0.9 @ 230 V AC | 90% @ 115 V AC 92% @ 230 V AC | 325 | 3.54" | 2.17" | 3.48" | UL Listed, C-UL Listed, CE Marked, TUV Rheinland Certified, SEMI F47 Compliant | 0000000 | 0000000 |
24V DC (21.6-28V DC) | 10 | 15 A, 3 seconds | 240 | 140 | 0.9 @ 230 V AC | 91% @ 115 V AC 93% @ 230 V AC | 325 | 4.93" | 1.5" | 4.7" | UL Listed, C-UL Listed, CE Marked, TUV Rheinland Certified, SEMI F47 Compliant | 0000000 | 000000 |
24V DC (21.6-28V DC) | 20 | 30 A, 3 seconds | 480 | 130 | 0.9 @ 230 V AC | 92% @ 115 V AC 94% @ 230 V AC | 325 | 4.93" | 2.36" | 4.7" | UL Listed, C-UL Listed, CE Marked, TUV Rheinland Certified, SEMI F47 Compliant | 0000000 | 000000 |
24V DC (23-24.1V DC) | 3.75 | __ | 90 | 300 | Not Rated | 86% @ 115 V AC 87% @ 230 V AC | 325 | 3.54" | 2.17" | 3.48" | UL Listed, C-UL Listed, CE Marked, TUV Rheinland Certified, SEMI F47 Compliant | 0000000 | 000000 |