McMaster-Carr logo
    Filter by
    Electrical Phase
    For Number of Fuses
    Number of Circuits Controlled
    Number of Wires
    Fuse UL Class
    Knockout Trade Size
    Industrial Info Compare
    Housing Material
    For Wire Gauge
    Industrial Info Compare
    Number of Mounting Holes
    Actuator Color
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Housing Color
    Electrical Connection
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    16 Products

    Durable Disconnect Switches

    Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Durable Disconnect Switches.
    Fuse Holder—Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Each
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3RK1, RK5, K5, H14 1/4"6 5/8"5/16"Tab TerminalNEMA 1
    UL Listed
    7524K2100000007524K414000000
    100240V AC/250V DCDPST
    Single (15 hp @ 240V AC)3RK1, RK5, K5, T, H17 1/2"11 3/16"5/16"Tab TerminalNEMA 1
    UL Listed
    7524K230000007524K41300000
     
    2 Circuits Controlled with Lockout and Fuse Holder
    60240V AC/250V DCDPST
    Single (10 hp @ 240V AC)3RK1, RK5, K5, H10 1/16"6 7/16"5/16"Tab TerminalNEMA 1
    UL Listed
    7524K220000007524K41200000
     
    Fuse Holders

    Outdoor Durable Disconnect Switches

    All switches have quick-make/quick-break action to eliminate arcing and prolong switch life.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Outdoor Durable Disconnect Switches.
    Powder-Coated Steel Housing—The enclosure is steel, so it withstands tougher conditions than plastic enclosures.
    Fuse Holder—Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
    Lockout—They have a lockout to secure in the off position using a padlock (not included).
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    NEMA 3R Enclosure Rating—A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Each
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    100240V AC/250V DCDPST
    Single (15 hp @ 240V AC)3RK1, RK5, K5, T, H17 1/2"11 3/16"5/16"Tab TerminalNEMA 3R
    UL Listed
    7524K2600000007524K413000000
     
    2 Circuits Controlled with Lockout and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)3RK1, RK5, K5, H8 9/16"5 7/16"5/16"Tab TerminalNEMA 3R
    UL Listed
    7524K24000007524K411000000
    60240V AC/250V DCDPST
    Single (10 hp @ 240V AC)3RK1, RK5, K5, H10 1/16"6 7/16"5/16"Tab TerminalNEMA 3R
    UL Listed
    7524K250000007524K41200000
     
    Fuse Holders

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Two-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 2 Circuits Controlled, Lockout.

    Two-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Photovoltaic—Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
    Switching
    Current,
    amp
    Voltage,
    V DC
    Switch
    Designation
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure Rating
    Certification
    Each
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout/Photovoltaic
    20800DPST
    9 13/16"6 5/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K720000000
    32800DPST
    11"7 1/2"5/16"Screw TerminalIP66
    IP67
    NEMA 3S
    NEMA 6P
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    6759K73000000
    50800DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K74000000
    63650DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K71000000
     
    Labels
    back to top