    3 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Riser-Rated Communication and Security System Cable

    This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Specs.
    Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    1222/12
    0.23"PVC
    GrayPVC
    Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow0 to 140CMR, CL3R
    UL 4448280T350000000000000000000000000000000
     

    Duct-Rated Communication and Security System Cable

    Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Specs. Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    822/8
    0.19"PVC
    WhitePVC
    Black, Blue, Brown, Green, Orange, Red, White, Yellow0 to 165CMP, CL3P
    UL 13, UL 4448280T140000000000000000000000000000000
    22
    1222/12
    0.23"PVC
    WhitePVC
    Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow0 to 165CMP, CL3P
    UL 13, UL 4448280T1500000000000000000000000000
     