Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 9 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 000000 |
14 | 15 | 125V AC | 6 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 0000 |
90° Elbow NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 0000 |
16 | 13 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
Light Duty Power Cords





Use SJT cords in dry or damp locations.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
18 | 10 | 125V AC | 9 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 1/2 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
IEC C14 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.33" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
Sure-Grip Power Cords



Also known as hospital-grade cords, these cords have an extra-tight connection to prevent them from detaching. The plug is marked with a green dot.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 8 ft. | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 00000 |
16 | 13 | 125V AC | 12 ft. | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 00000 |
NEMA 5-20 Plug × Wire Leads | |||||||||||
14 | 20 | 125V AC | 10" | 0.37" | PVC Plastic | SJT | -20° to 220° | UL Listed, C-UL Listed | Gray | 00000000 | 0000 |
Electronic Equipment Power Cords


















Use these cords with computers, lab equipment, and office machines that have IEC connections.
Cords with a 90° elbow socket fit flush against equipment, so equipment can be pushed against a wall.
Use SJT cords in dry or damp environments.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × IEC C17 Socket | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.3" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 000000 |
NEMA 5-15 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 3 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 9 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 3 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 7 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 3 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 0000 |
14 | 15 | 125V AC | 6 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
14 | 15 | 125V AC | 10 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
NEMA 5-15 Plug × IEC C15 Socket | |||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
14 | 15 | 250V AC | 8 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
NEMA 5-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 5-15 Plug × 90° Elbow IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 9 1/2 | 0.33" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
18 | 10 | 125V AC | 14 | 0.3" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
16 | 13 | 125V AC | 6 1/2 | 0.35" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 5-15 Plug × 90° Elbow IEC C15 Socket | |||||||||||
14 | 15 | 125V AC | 8 | 0.36" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
NEMA 5-20 Plug × IEC C19 Socket | |||||||||||
12 | 20 | 125V AC | 8 | 0.45" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 6-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 250V AC | 8 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 6-20 Plug × IEC C19 Socket | |||||||||||
12 | 20 | 250V AC | 8 | 0.45" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
IEC C14 Plug × NEMA 5-15 Socket | |||||||||||
16 | 13 | 125V AC | 2 | 0.33" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 0000 |
IEC C14 Plug × IEC C5 Socket | |||||||||||
18 | 7 | 250V AC | 6 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
IEC C14 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 1 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 3 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
16 | 13 | 250V AC | 6 | 0.35" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
14 | 15 | 250V AC | 6 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
14 | 15 | 250V AC | 10 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
IEC C14 Plug × IEC C15 Socket | |||||||||||
14 | 15 | 250V AC | 6 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
IEC C14 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 250V AC | 6 | 0.37" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
IEC C14 Plug × 90° Elbow IEC C13 Socket | |||||||||||
18 | 10 | 250V AC | 2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 0000 |
IEC C20 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 250V AC | 3 | 0.37" | PVC Plastic | SJT | 15° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
14 | 15 | 250V AC | 6 1/2 | 0.32" | PVC Plastic | SJT | -40° to 155° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
12 | 20 | 250V AC | 6 | 0.43" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
Sure-Grip Coiled Electronic Equipment Power Cords



Tug these cords to full length, and they’ll stay plugged in. Also called hospital-grade cords, they form an extra-tight connection with outlets. After stretching, they return to a tight, tangle-free coil. Use them for computers, lab equipment, and other machines that have IEC connections. They'll stand up to damp environments thanks to their insulation, which is designated as SJT. The plug is marked with a green dot, indicating it is hospital-grade.
Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Retracted Lg., ft. | Wire Gauge | Current, A | Voltage | Features | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | |||||||||||||
8 | 2 | 18 | 10 | 125V AC | Green Dot | 0.3" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 0000000 | 000000 |
Sure-Grip Electronic Equipment Power Cords






Also known as hospital-grade cords, these cords have an extra-tight connection to prevent them from detaching. The plug is marked with a green dot. Use them with computers, lab equipment, and office machines that have IEC connections.
Cords with a 90° elbow socket fit flush against equipment, so equipment can be pushed against a wall.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 220° | UL Listed, CSA Certified, IEC 60320 | Gray | 00000000 | 000000 |
18 | 10 | 125V AC | 10 | 0.31" | PVC Plastic | SJT | 0° to 220° | UL Listed, CSA Certified, IEC 60320 | Gray | 00000000 | 00000 |
16 | 13 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 220° | UL Listed, CSA Certified, IEC 60320 | Gray | 00000000 | 00000 |
16 | 13 | 125V AC | 15 | 0.34" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
14 | 15 | 125V AC | 10 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Gray | 000000000 | 00000 |
NEMA 5-15 Plug × 90° Elbow IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 10 | 0.31" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
18 | 10 | 125V AC | 15 | 0.31" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000000 | 00000 |
16 | 13 | 125V AC | 10 | 0.34" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Gray | 00000000 | 00000 |
16 | 13 | 125V AC | 13 | 0.34" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Gray | 000000000 | 00000 |
14 | 15 | 125V AC | 10 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 5-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 125V AC | 10 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 6-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 250V AC | 10 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
Electronic Equipment Cord Splitters
Power multiple devices from one power source. Use these splitters with computers, lab equipment, and office machines that have IEC connections.
Use SJT cords in dry or damp locations.





Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | Plug End OD | Socket End OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
IEC C14 Plug × IEC C13 Socket | ||||||||||||
18 | 10 | 250V AC | 6 | 0.31" | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 0000000 | 000000 |
IEC C20 Plug × IEC C19 Socket | ||||||||||||
12 | 20 | 250V AC | 6 | 0.44" | 0.44" | PVC Plastic | SJT | 15° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 0000000 | 00000 |



Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | Plug End OD | Socket End OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | ||||||||||||
18 | 10 | 125V AC | 7 | 0.11" | 0.11" | PVC Plastic | SJT | -40° to 140° | UL Recognized Component, C-UL Recognized Component, IEC 60320 | Black | 000000 | 000000 |



Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | Plug End OD | Socket End OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
IEC C13 Socket × IEC C14 Plug and IEC C13 Socket | ||||||||||||
18 | 10 | 250V AC | 6 | 0.11" | 0.11" | PVC Plastic | SJT | -40° to 220° | UL Recognized Component, C-UL Recognized Component, IEC 60320 | Black | 000000 | 000000 |
Shielded Electronic Equipment Power Cords



The shielding blocks signal interference from nearby equipment and devices. Use these cords with computers, lab equipment, and office machines that have IEC connections.
Use SJT cords in dry or damp locations.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Shield Type | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | ||||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Foil | Black | 00000000 | 000000 |
Locking Electronic Equipment Power Cords









Create a vibration-resistant connection—the socket on these cords securely locks onto any male receptacle and will not detach until manually unlocked. Use them with computers, lab equipment, and office machines that have IEC connections.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 6 | 0.11" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 000000 |
14 | 15 | 125V AC | 6 | 0.36" | PVC Plastic | SJT | 0° to 220° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
NEMA 5-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 125V AC | 6 1/2 | 0.14" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
IEC C13 Plug × IEC C14 Socket | |||||||||||
14 | 15 | 250V AC | 6 | 0.36" | PVC Plastic | SJT | 0° to 220° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
IEC C14 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 250V AC | 6 | 0.11" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
IEC C20 Plug × IEC C19 Socket | |||||||||||
12 | 20 | 250V AC | 6 | 0.43" | PVC Plastic | SJT | 0° to 220° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
Sure-Grip Locking Electronic Equipment Power Cords



Create a secure, vibration-resistant connection on both ends—these cords have a hospital-grade plug and a locking connector on the socket. The plug has an extra-tight connection to stay plugged into your electrical outlet. A lock on the socket flips over the male receptacle on your equipment. The lock will keep the connection in place until it is manually unlocked. Designated SJT, these cords are safe to use in dry or damp locations. Use with computers, lab equipment, and other machines with IEC connections. The plug is marked with a green dot, indicating it is hospital-grade.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 6 | 0.3" | PVC Plastic | SJT | 0° to 220° | IEC 60320 | Black | 0000000 | 000000 |
18 | 10 | 125V AC | 10 | 0.3" | PVC Plastic | SJT | 5° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 0000000 | 00000 |
Turn-Lock Power Cords







The plug on these cords turns to lock in an outlet, so they remain securely attached in high-vibration applications.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA Plug × Wire Leads | ||||||||||||
L5-15 | 14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 000000 |
L5-20 | 12 | 20 | 125V AC | 8 | 0.44" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L5-20 | 12 | 20 | 125V AC | 12 | 0.42" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 0000000 | 00000 |
L5-30 | 10 | 30 | 125V AC | 8 | 0.56" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L6-15 | 14 | 15 | 250V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L6-20 | 12 | 20 | 250V AC | 8 | 0.44" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L6-30 | 10 | 30 | 250V AC | 8 | 0.56" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
Electronic Equipment Turn-Lock Power Cords








Use these cords with computers, lab equipment, and office machines that have IEC connections. They have a plug that turns to lock in an outlet, so they remain securely attached in high-vibration applications.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA L5-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 000000 |
NEMA L5-20 Plug × IEC C19 Socket | |||||||||||
12 | 20 | 125V AC | 8 | 0.45" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
NEMA L6-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 250V AC | 8 | 0.38" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
NEMA L6-20 Plug × IEC C13 Socket | |||||||||||
14 | 15 | 250V AC | 6 | 0.36" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 0000000 | 00000 |
NEMA L6-20 Plug × IEC C19 Socket | |||||||||||
12 | 20 | 250V AC | 8 | 0.45" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 00000 |
NEMA L6-30 Plug × IEC C19 Socket | |||||||||||
12 | 20 | 250V AC | 12 | 0.43" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 0000000 | 00000 |
Light Duty Multi-Outlet Extension Cords
Designed for indoor applications, these cords are often used to power multiple appliances from one outlet.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Use SJT cords in dry or damp locations.




Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | No. of Outlets | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||||
8 | 3 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.36" | PVC Plastic | SJT | UL Listed | Black | 0000000 | 000000 |
15 | 3 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.36" | PVC Plastic | SJT | UL Listed | Black | 0000000 | 00000 |
90° Elbow NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||||
6 | 3 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.37" | PVC Plastic | SJT | UL Listed | White | 000000000 | 00000 |
Coiled Extension Cords



These self-coiling cords stretch to full length and then return to their retracted length for tangle-free storage.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Use SJT cords in dry or damp locations.
Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Retracted Lg. | Wire Gauge | Current, A | Voltage | Power-Indicating Light | Coil OD | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
90° Elbow NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||||
10 | 36" | 16 | 13 | 125V AC | Without Power-Indicating Light | 1.63" | 0.33" | PVC Plastic | SJT | UL Listed | Orange | 0000000 | 000000 |
Sure-Grip Extension Cords



Also known as hospital-grade cords, these have extra-tight connections to prevent them from detaching. The connectors are marked with a green dot.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Power-Indicating Light | Features | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
6 ft. | |||||||||||
16 | 13 | 125V AC | Without Power-Indicating Light | Green Dot | 0.32" | PVC Plastic | SJT | UL Listed, CSA Certified | Gray | 000000 | 000000 |
14 | 15 | 125V AC | Without Power-Indicating Light | Green Dot | 0.36" | PVC Plastic | SJT | UL Listed, CSA Certified | Gray | 000000 | 00000 |
15 ft. | |||||||||||
14 | 15 | 125V AC | Without Power-Indicating Light | Green Dot | 0.36" | PVC Plastic | SJT | UL Listed, CSA Certified | Gray | 000000 | 00000 |
Extension Cord Adapters



Change the connection style between an outlet and your equipment.
Use SJT adapters in dry or damp locations.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Color | Each | |
NEMA 5-20 Plug × NEMA L5-20 Socket | ||||||||||
1 ft. | 12 | 20 | 125V AC | Without Power-Indicating Light | 0.43" | PVC Plastic | SJT | Black | 0000000 | 000000 |
Extension Cord Splitters
Power multiple devices from the same outlet with these splitters.
Two-outlet and three-outlet splitters plug into an outlet or extension cord.Splitters with a 90° elbow plug sit flush against wall outlets to fit in tight spaces.
Use SJT and SPT-2 splitters in dry or damp locations.
For technical drawings and 3-D models, click on a part number.






Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
1 | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.33" | PVC Plastic | SJT | UL Listed, C-UL Listed | Black | 00000000 | 000000 |
1 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.37" | PVC Plastic | SJT | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
90° Elbow NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
1 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.37" | PVC Plastic | SJT | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
NEMA L6-20 Plug × NEMA L6-20 Socket | |||||||||||
3 | 10 | 20 | 250V AC | Without Power-Indicating Light | 0.57" | PVC Plastic | SJT | UL Listed, C-UL Listed | Black | 00000000 | 000000 |
Cable

Use this general purpose cable to supply power to equipment.
- Use for: Power Supply
- Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
SJT cable is for use in dry or damp locations. The insulation withstands exposure to humidity and low levels of moisture.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.31" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.34" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 |