Shielded Micro M12 Screw-Together Connectors
Block signal interference from nearby devices, such as motors and transmitters, while maintaining a strong, stable connection for M12 threads. The shielding on these connectors maintains signal integrity and minimizes signal loss between equipment. The threaded housing creates a secure connection that withstands the shaking and vibrating of industrial automation.
A-coded, these connectors are often used to connect equipment to IO Link controllers and devices within Profibus, DeviceNet, and other fieldbus systems. They work with both AC and DC devices such as sensors, motors, and light curtains. Poles and keyways on their face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
Connectors with polyurethane outer insulation are halogen free, so they won’t release toxic fumes or cause corrosion in metal. Polyurethane resists chemicals, oil, and UV rays, and is very flexible. It’s good for use in industrial environments and robotics.
All meet IP ratings when either mated or capped. IP66K rated connectors are dust tight and protected from washdowns. IP67 rated connectors are protected from dust and temporary submersion.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: They may have extra holes on the face that are not used.

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
| 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.21" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 000000 |
| 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.22" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 00000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 00000 |
| 12 | A | 0.3" | 30V AC/30V DC | 1.5A | 26 | 0.26" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67 | 0000000 | 000000 |
16 ft. Cable Lead Lg. | |||||||||||||||
| 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.21" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 00000 |
| 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.22" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 00000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 0000000 | 000000 |
| 12 | A | 0.3" | 30V AC/30V DC | 1.5A | 26 | 0.26" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67 | 0000000 | 000000 |

| For Thread Size | Material | Each | |
For Sockets with Internal Threads | |||
|---|---|---|---|
| M12 | Anodized Aluminum | 0000000 | 000000 |
Status-Indicating Micro M12 Screw-Together Connectors
Visually confirm your connector is working properly. A green light means your connector has power, while yellow means it has signal. If either light is off, you'll know whether you need to inspect your signal or power source. Because these connectors thread tightly onto M12 connections, they won’t let in contaminants or come loose from vibration in rugged industrial environments. Their poles and keyways adhere to standard coding layouts, reducing the chance you’ll mismatch connectors. All have A coding, so they send signal and power to AC and DC sensors, actuators, motors, light curtains, and other devices. They’re also often used to connect equipment to IO Link controllers and in Profibus, DeviceNet, and other fieldbus systems.
PVC insulation means these connectors resist abrasion and work well in indoor general purpose applications. IP66K and IP67 rated when mated, all block out dust and water from high-pressure washdowns or brief submersion.
Connectors with 5 poles can send two signals. An additional white light lets you know the connector is carrying the second signal.
90° elbow connectors fit snugly against equipment, so they’re good for tight spaces.
Add caps to protect connectors and maintain their IP ratings when not in use.

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Wire Leads | Number of Poles | Coding | Face Diameter | Voltage | Current | Wire Lead Gauge | Cable OD | Size | Pitch, mm | Type | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.18" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 000000 |
| 5 | 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 00000 |
32.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.18" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 00000 |
| 5 | 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Wire Leads | Number of Poles | Coding | Face Diameter | Voltage | Current | Wire Lead Gauge | Cable OD | Size | Pitch, mm | Type | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.18" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 000000 |
| 5 | 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 00000 |
32.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.18" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 00000 |
| 5 | 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | M12 | 1 | Metric | 25° to 175° | IP67, IP66K | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 0000000 | 00000 |

For Thread | ||||
|---|---|---|---|---|
| Size | Location | Material | Each | |
For Sockets | ||||
| M12 | Internal | Anodized Aluminum | 0000000 | 000000 |
Nano M8 Connectors
Also known as pico connectors, these are for low-current devices such as 8 mm and smaller proximity switches and photoelectric switches.
To view wiring diagrams, select a part number and click Product Detail.
IP66K rated connectors protect against dust and washdowns. IP67 rated connectors protect against dust and temporary submersion. Note: Sockets and female receptacles may have extra holes on the face that are not used.

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
32.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.18" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.19" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
32.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.18" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.19" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
32.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.18" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.19" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
32.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.18" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.19" | PVC Plastic | Black | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |
Status-Indicating Nano M8 Connectors

Visually check that your low-current devices with M8 connections are powered up and sending and receiving signals. These connectors illuminate green if they have power and yellow if they have signal. If either light is off, you’ll know whether you need to inspect your signal or power source. Also known as pico connectors, M8 connectors are often used with 8 mm and smaller proximity switches and photoelectric switches.
These connectors are IP66K and IP67 rated when mated, so they seal out dust and water from high-pressure washdowns and temporary submersion.
Housing Thread | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | Wire Lead Gauge | Cable OD | Color | For Signal Output Type | Housing Material | Size | Pitch, mm | Light Technology | Light Color | Temp. Range, ° F | Environmental Rating | Each | |
6 1/2 ft. Wire Lead Lg. | |||||||||||||||||
90° Elbow Socket with Wire Leads—Internal Thread | |||||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.18" | Clear | PNP | Polyurethane Rubber | M8 | 1 | LED | Green, Yellow | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
16 1/2 ft. Wire Lead Lg. | |||||||||||||||||
90° Elbow Socket with Wire Leads—Internal Thread | |||||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 24 | 0.18" | Clear | PNP | Polyurethane Rubber | M8 | 1 | LED | Green, Yellow | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |
Shielded Nano M8 Connectors
Minimize signal loss between low-current devices with M8 connections. The shielding on these connectors reduces signal interference from nearby devices, such as motors and speed controls. Also known as pico connectors, M8 connectors are often used with 8 mm and smaller proximity switches and photoelectric switches.
To view wiring diagrams, select a part number and click Product Detail.
IP or NEMA rated when mated, all seal out dust. IP66K rated connectors protect against high-pressure washdowns. IP67 rated connectors seal out water from temporary submersion.

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
6.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |
16.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
6.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |
16.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 0000000 | 00000 |