About Electrical Enclosures
Select the right electrical enclosure for your environment and the accessories you'll need to get it mounted and connected.
Hazardous-Location Enclosures
![]() | ![]() |
Lift-Off Cover | Hinged Cover |
Protect your people and parts from explosive risks in areas with flammable gases, combustible dust, and ignitable fibers. These NEC-rated enclosures are often used to shield motor controls, power supplies, and wiring in plants that handle or make fuel, bulk powders, and chemicals. Plus, they lock out water to keep your electrical components dry.
Lift-Off Cover—The removable, screw-secured cover is best for full access during setup or service, but not for frequent entry.
Hinged Cover—The cover swings open for fast, frequent access and remains attached to prevent drops or loss.
Aluminum—Best for housing sensors and other sensitive electronics where interference is a concern, these enclosures block wireless and radio signals. They’re also a rust-resistant alternative to stainless steel in wet areas.
Electrical Enclosures | Panels | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Cover Closure Method | With Knockouts | Enclosure Rating | Hazardous Location Rating | External Mount Type | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Lift-Off Cover | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Aluminum | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10" | 10" | 6" | Screw | No | NEMA 4, NEMA 7, NEMA 9, IP66 | NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA | Bracket | 7624K21 | 000000000 | 7624K31 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12" | 12" | 8" | Screw | No | NEMA 4, NEMA 7, NEMA 9, IP66 | NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA | Bracket | 7624K22 | 00000000 | 7624K32 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14" | 12" | 8 1/2" | Screw | No | NEMA 4, NEMA 7, NEMA 9, IP66 | NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA | Bracket | 7624K23 | 00000000 | 7624K33 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hinged Cover | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Aluminum | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17" | 17" | 9" | Screw | No | NEMA 4, NEMA 7, NEMA 9, IP66 | NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA | Bracket | 7624K24 | 00000000 | 7624K34 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17" | 17" | 11" | Screw | No | NEMA 4, NEMA 7, NEMA 9, IP66 | NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA | Bracket | 7624K25 | 00000000 | 7624K34 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hazardous-Location Electrical Enclosure Drains
![]() |
Safe for use around flammable and combustible gases, vapors, fibers, and dust, these drains let moisture buildup from temperature changes inside enclosures drip out to keep electronics dry. Mount them at the bottom of enclosures.
1/2 Pipe Size—1/2 pipe size drains also stand up to washdowns and weather.
Pipe Size | Thread Type | Drive Style | Hex Size | Head Dia. | Ht. | Material | Hazardous Location Protection Type | Hazardous Location Rating | Enclosure Rating | Environment | UL File No. | CSA File No. | Specs. Met | Certification | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3/8 | NPT Male | External Hex | 7/8" | 15/16" | 1 3/4" | 303 Stainless Steel | Dust-Ignition Proof, Explosion Proof | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | — | Hazardous | E34997 | 065181_0_000 | UL 886 | UL Listed, CSA Certified | 7495N112 | 000000 | |
1/2 | NPT Male | External Hex | 7/8" | 15/16" | 1 3/4" | 304 Stainless Steel | Dust-Ignition Proof, Explosion Proof | NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | NEMA 4X | Corrosive, Dusty, Hazardous, Washdown, Outdoor, Wet | E34997 | 065181_0_000 | UL 886 | UL Listed, CSA Certified | 7495N111 | 000000 |
Threaded Plugs for Enclosures
![]() |
Screw into unused threaded holes in enclosures, outlet boxes, junction boxes, and electrical panels for a more secure hold than clamp-on and snap-in plugs. Use these plugs to protect your electrical components in dusty or hazardous locations. Install them from the outside.
Pipe Size | Head Dia. | Hazardous Location Rating | Certification | Specs. Met | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aluminum | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1/2 | 3/4" | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | CSA Certified, UL Listed | UL 886, UL 1203 | 7280K11 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3/4 | 1" | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | CSA Certified, UL Listed | UL 886, UL 1203 | 7280K12 | 0000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 | 1 1/4" | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | CSA Certified, UL Listed | UL 886, UL 1203 | 7280K13 | 0000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 1/4 | 1 1/2" | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | CSA Certified, UL Listed | UL 886, UL 1203 | 7280K14 | 0000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 1/2 | 1 3/4" | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | CSA Certified, UL Listed | UL 886, UL 1203 | 7280K15 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2 | 2 1/4" | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | CSA Certified, UL Listed | UL 886, UL 1203 | 7280K16 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||