    68 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Lead Wire

    Also known as hook-up wire, this wire is primarily used for wiring electrical panels, lighting, and plant floor equipment. It meets UL 1007, UL 1015, or UL 1569 for appliance wiring.
    Stranded Wire—300V AC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM Style
    Choose an Outer Jacket Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    28
    7/36
    4 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T310000000000000000000000000000
    26
    7/34
    5 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T1100000000000000000000000
    24
    7/32
    7 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T1200000000000000000000000
    22
    7/30
    10 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Blue/White, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, Red/White, White, Yellow8054T1300000000000000000000000
    20
    10/30
    13 amp @ 86° F0.07"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Blue/White, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, Red/White, White, Yellow8054T1400000000000000000000000
    18
    16/30
    18 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Blue/White, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, Red/White, White, Yellow8054T15000000000000000000000000
    16
    26/30
    24 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, White, Yellow8054T160000000000000000000000000
    14
    41/30
    33 amp @ 86° F0.11"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, White, Yellow8054T1700000000000000000000000000
    12
    65/30
    45 amp @ 86° F0.12"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, White, Yellow8054T18000000000000000000000000000
    10
    105/30
    58 amp @ 86° F0.16"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T190000000000000000000000000000
    Solid Wire—300V AC
    Image of Product. Front orientation. Solid Wire. Lead Wire.
    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM Style
    Choose an Outer Jacket Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    26
    5 amp @ 86° F0.05"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow8251T9000000000000000000000000000
    24
    7 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow8251T100000000000000000000000
    22
    10 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, White, Yellow8251T200000000000000000000000
    20
    13 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, White, Yellow8251T300000000000000000000000
    18
    18 amp @ 86° F0.07"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, White, Yellow8251T4000000000000000000000000
    16
    24 amp @ 86° F0.1"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1007, 1569Black, Blue, Brown, Green, Orange, Red, White, Yellow8251T800000000000000000000000000
    14
    33 amp @ 86° F0.11"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1569Black, Blue, Brown, Green, Orange, Red, White, Yellow8251T700000000000000000000000000
    12
    45 amp @ 86° F0.13"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1569Black, Blue, Brown, Green, Orange, Red, White, Yellow8251T6000000000000000000000000000
    10
    58 amp @ 86° F0.16"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1569Black, Blue, Brown, Green, Orange, Red, White, Yellow8251T50000000000000000000000000000
    Stranded Wire—300V AC/300V DC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Metric wire is also known as Harmonized European Wire and meets HAR H05V-K for size (mm2), material, and voltage. It can also be used on North American electrical panels and machines.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    AWG
    Metric Wire
    Size, mm²
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    AWM Style
    Choose an Outer
    Jacket Color
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    500 ft.
    Long
    22
    0.516/0.21 mm²
    3 amp @ 86° F0.09"-40 to 220PVCCE Marked, CSA Certified, HAR Marked H05V-K, UL Recognized Component
    1007, 1569Black, Blue, Green/Yellow6513T100000000000000000000000
    20
    0.7524/0.21 mm²
    5 amp @ 86° F0.09"-40 to 220PVCCE Marked, CSA Certified, HAR Marked H05V-K, UL Recognized Component
    1007, 1569Black, Blue, Green/Yellow6513T200000000000000000000000000
    18
    132/0.21 mm²
    18 amp @ 86° F0.1"-40 to 220PVCCE Marked, CSA Certified, HAR Marked H05V-K, UL Recognized Component
    1007, 1569Black, Blue, Green/Yellow6513T30000000000000000000000000

    Lead Wire Assortments

    Image of Product. Five Spools. Front orientation. 5. Lead Wire Assortments.
    Image of Product. Eight Spools. Front orientation. 8. Lead Wire Assortments.

    Five Spools

    Eight Spools

    Keep spools of wire in multiple colors on hand; each assortment includes one spool of each color listed. Mount the included rack (fasteners not included) or use it to transport wire. Also known as hook-up wire, it’s primarily used for wiring electrical panels, lighting, and plant for equipment. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Wire meets UL standards for appliance wiring.
    Stranded Wire—Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Solid Wire—Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    Mount
    Holes
    25 ft. Long
    100 ft. Long
    No. of
    Spools
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket Color
    Certification
    Flammability
    Rating
    AWM Style
    No.
    of
    Dia.
    Each
    Each
    Stranded Wire
     
    300V AC
    526
    7/34
    5 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T230000009948T28000000
    524
    7/32
    7 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T24000009948T2900000
    522
    7/30
    10 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T25000009948T3100000
    520
    10/30
    13 amp @ 86° F0.07"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T26000009948T3200000
    518
    16/30
    18 amp @ 86° F0.08"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T27000009948T33000000
    516
    26/30
    24 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N11000006616N31000000
    514
    41/30
    33 amp @ 86° F0.11"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N1200000———0
    512
    65/30
    45 amp @ 86° F0.12"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N13000000———0
    826
    7/34
    5 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4100000———0
    824
    7/32
    7 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4200000———0
    822
    7/30
    10 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4300000———0
    820
    10/30
    13 amp @ 86° F0.07"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4400000———0
    818
    16/30
    18 amp @ 86° F0.08"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4500000———0
     
    Solid Wire
     
    300V AC
    526
    5 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6632N1100000———0
    524
    7 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"6632N12000009948T4400000
    522
    10 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"6632N13000009948T4500000
    520
    13 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"6632N14000009948T4600000
    518
    18 amp @ 86° F0.07"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"6632N15000009948T47000000
    824
    7 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T2100000———0
    822
    10 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T2200000———0
    820
    13 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T1700000———0
    818
    18 amp @ 86° F0.07"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T1800000———0
     

    Quick-Disconnect Terminals with Wire Leads

    Image of Product. Front orientation. Jumper Cords. Quick-Disconnect Terminals with Wire Leads , Female.

    Female

    These terminals are connected to a single-conductor wire lead. The terminal connection tab is completely covered with insulation, leaving no metal exposed when mated. They slide together and pull apart with ease, so they are convenient for applications that require frequent connections. Use a crimper (not included) to install wire.
    Tab
    12"
    Overall Length
    24"
    Overall Length
    AWG
    Wd.
    Thk.
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    AWM
    Style
    Insulation
    Material
    Choose an Insulation
    Color
    Pkg.
    Qty.
    Pkg.
    Pkg.
    Female
    22
    1/4"0.032"Tin-Plated Brass220300V AC
    300V DC
    1569Nylon
    Black, Red107548K450000007548K55000000
    18
    1/4"0.032"Tin-Plated Brass220300V AC
    300V DC
    1569Nylon
    Black, Red107548K46000007548K5600000
    14
    1/4"0.032"Tin-Plated Brass220300V AC
    300V DC
    1569Nylon
    Black, Red107548K47000007548K5700000
     

    Ring Terminal Jumper Cords

    Image of Product. Front orientation. Contains Annotated. Jumper Cords. Ring Terminal Jumper Cords .
    Save preparation time—these cords are ready-to-use with ring terminals on each end of a single-conductor wire.
    12"
    Overall Length
    24"
    Overall Length
    AWG
    For Screw
    Size
    For Screw Size
    Decimal Equiv.
    Ring
    Wd.
    Wire
    Construction
    Wire
    Material
    Terminal
    Material
    Max. Temp.,
    ° F
    Max. Voltage
    AWM Style
    Insulation
    Material
    Wire Insulation
    Material
    Choose an Insulation
    Color
    Pkg.
    Qty.
    Pkg.
    Pkg.
    22
    No. 10
    0.19"0.31"Stranded
    CopperTin-Plated Copper220300V AC
    300V DC
    1007, 1569Vinyl PlasticPVC
    Black, Green, Red107548K150000007548K25000000
    18
    No. 10
    0.19"0.31"Stranded
    CopperTin-Plated Copper220300V AC
    300V DC
    1007, 1569Vinyl PlasticPVC
    Black, Green, Red107548K16000007548K2600000
    16
    No. 10
    0.19"0.31"Stranded
    CopperTin-Plated Copper220300V AC
    300V DC
    1007, 1569Vinyl PlasticPVC
    Black, Green, Red107548K17000007548K2700000
    14
    No. 10
    0.19"0.31"Stranded
    CopperTin-Plated Copper220300V AC
    300V DC
    1569Vinyl PlasticPVC
    Black, Green, Red107548K18000007548K2800000
     
    back to top