    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Building Wire

    Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
    Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. TFFN, THHN/THWN, and THHN/THWN-2 Stranded. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Stranded Wire.

    TFFN, THHN/THWN, and THHN/THWN-2

    Stranded

    Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Wire with a nylon outer jacket resists oil and water.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN-2 Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose an Outer Jacket Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    8
    19/21
    55 amp @ 86° F0.21"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T16000005007715T560000000
    6
    19/19
    75 amp @ 86° F0.25"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1700005007715T57000000
    4
    19/17
    95 amp @ 86° F0.32"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1800005007715T58000000
    3
    19/16
    110 amp @ 86° F0.35"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1900005007715T5900000000
    2
    19/15
    130 amp @ 86° F0.38"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T2100005007715T6100000000
    1/0
    19/13
    170 amp @ 86° F0.47"-10 to 190THHN, THWN-2
    UL Listed
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T2200005007715T6200000000
    2/0
    19/12
    195 amp @ 86° F0.52"-10 to 190THHN, THWN-2
    UL Listed
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T2300005007715T6300000000
     

    Aluminum Building Wire

    Image of Product. Side1 orientation. Building Wire. Aluminum Building Wire.
    Mend or extend aluminum wire often found in older buildings. This wire isn’t recommended for new wiring, since it’s more likely to overheat than copper when conducting electricity. However, it’s safer to maintain existing aluminum wire with aluminum rather than mixing materials. Building wire is also known as branch circuit wire.
    This wire has an outer layer of nylon insulation that won't degrade from oil and water. It’s designed to be pulled through conduit without pulling lubricants. THHN and THWN-2 designated, this wire can be used in damp places.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
     
    600V AC/600V DC
    6
    55 amp @ 86° F0.24"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N1100000000000000000000000000000000
    4
    75 amp @ 86° F0.3"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N12000000000000000000000000000
    2
    100 amp @ 86° F0.36"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N13000000000000000000000000000
    1
    115 amp @ 86° F0.41"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N14000000000000000000000000000
    1/0
    135 amp @ 86° F0.45"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N15000000000000000000000000000
    2/0
    150 amp @ 86° F0.49"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N160000000000000000000000000000
     
    back to top