    9 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Outdoor Lead Wire

    The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
    2,000V AC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 2,000V AC.
    DLO Cable—DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An outer layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
    UL 2556 FT4—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing.
    AWG
    Current @
    Temp.
    OD
    Max. Temp.,
    ° F
    Outer Jacket
    Material
    Inner Insulation
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire
    12
    Not Rated0.21"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T24000000000000000000000000
    10
    Not Rated0.27"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T25000000000000000000000
    8
    55 amp @ 86° F0.33"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T260000000000000000000000
    6
    75 amp @ 86° F0.37"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T270000000000000000000000
    4
    95 amp @ 86° F0.44"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2800000000000000000000000
    2
    130 amp @ 86° F0.5"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2900000000000000000000000
    1/0
    170 amp @ 86° F0.65"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T31000000000000000000000000
    2/0
    195 amp @ 86° F0.69"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T32000000000000000000000000
    4/0
    260 amp @ 86° F0.82"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T3300000000000000000000000000
     
    back to top