About Actuated On/Off Valves
More
Flanged Motor-Driven On/Off Valves
- Valve Type: Butterfly
- For Use With: Water, Oil, Air, Natural Gas, Drinking Water, Propane, Butane, Argon, Helium, Neon, Steam, Xenon, Krypton
- Seal Material: EPDM Rubber
- Specifications Met: API 609, NSF/ANSI 61
Automatically start and stop flow in flanged pipelines with these valves that operate on electricity. All are fail in place; upon loss of power, the valve will remain in its current position.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. Valves meet NSF/ANSI Standard 61 for use with drinking water.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Valves with a manual override can be operated during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Port Type | Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Manual Override | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Ductile Iron Body with Screw Terminals | ||||||||||||||||
Fail in Place—24V AC/DC | ||||||||||||||||
Full | 2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 8 | -30° to 250° | 1 5/8" | 17 5/8" | 0000000 | 0000000 |
Full | 3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 8 | -30° to 250° | 1 3/4" | 19 3/16" | 0000000 | 000000 |
Full | 4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 9 | -30° to 250° | 2 1/16" | 21 5/8" | 0000000 | 000000 |
Full | 6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 27 | -30° to 250° | 2 3/16" | 24 13/16" | 0000000 | 00000000 |
Fail in Place—120V AC | ||||||||||||||||
Full | 2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 8 | -30° to 250° | 1 5/8" | 17 13/16" | 0000000 | 000000 |
Full | 3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 8 | -30° to 250° | 1 3/4" | 19 3/16" | 0000000 | 000000 |
Full | 4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 9 | -30° to 250° | 2 1/16" | 21 5/8" | 0000000 | 00000000 |
Full | 6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 27 | -30° to 250° | 2 3/16" | 24 13/16" | 0000000 | 00000000 |
Motor-Driven On/Off Valves for Fuel
- Valve Type: Butterfly
- For Use With: Oil, Natural Gas, Propane, Butane, Diesel Fuel, Ethylene Glycol, Fuel Oil, Gasoline, Kerosene
- Seal Material: Viton® Fluoroelastomer Rubber
- Specifications Met: API 609, MSS-SP-67
Use these valves to safely transfer fuel and oil. They operate on electricity to automatically start and stop flow. All are fail in place; upon loss of power, the valve will remain in its current position.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. The manual override allows you to operate the valve during power outages.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Ductile Iron Body with Screw Terminals | ||||||||||||||
Fail in Place—24V AC/24V DC | ||||||||||||||
2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | 8 | 10° to 350° | 1 5/8" | 17 13/16" | 0000000 | 0000000 |
3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | 8 | 10° to 350° | 1 3/4" | 19 3/16" | 0000000 | 000000 |
4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | 9 | 10° to 350° | 2 1/16" | 21 5/8" | 0000000 | 00000000 |
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 27 | 10° to 350° | 2 3/16" | 27 7/16" | 0000000 | 00000000 |
Fail in Place—120V AC | ||||||||||||||
2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | 8 | 10° to 350° | 1 5/8" | 17 13/16" | 0000000 | 000000 |
3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | 8 | 10° to 350° | 1 3/4" | 19 3/16" | 0000000 | 000000 |
4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | 9 | 10° to 350° | 2 1/16" | 21 5/8" | 0000000 | 00000000 |
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 27 | 10° to 350° | 2 3/16" | 27 7/16" | 0000000 | 00000000 |