McMaster-Carr logo
    Filter by
    Door Style
    Electromagnet Width
    Mounting Location
    Electromagnet Height
    Locking Speed
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Electromagnet Depth
    Strike Plate Depth
    Strike Plate Height
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    14 Products

    Electromagnetic Door Locks

    Image of ProductInUse. Front orientation. Contains Annotated. Electromagnetic Locks. Electromagnetic Door Locks, Flush Mount.

    Flush Mount

    Image of ProductInUse. Front orientation. Contains Annotated. Electromagnetic Locks. Electromagnetic Door Locks, Offset Mount.

    Offset Mount

    For use alone or as part of an access-control system, these locks use electromagnetic force to hold single doors closed. Control the locks with a push-button switch or keypad door control (sold separately). When power is interrupted, they instantly release. All locks must be hardwired.
    Delayed—Those with delayed locking speed lock doors after a set amount of time.
    Instant—Locks with instant locking speed lock doors as soon as they are closed.
    Flush Mount—Flush mount locks mount under the door frame header. For locks with 500 lbs. and 1,500 lbs. of holding strength, a 5/8" thick filler plate (sold separately) is required if the mounting surface on the frame is less than 2" wide.
    Offset Mount—Offset mount locks mount on the door frame header and include a mounting bracket that extends the strike plate above the door.
    Backup Battery Packs—Battery backup packs supply power during power interruptions.
    Locks
    Backup
    Battery Packs
    Door
    Filler Plates
    Electromagnet
    Strike
    Plate
    Flush Mount
    Offset Mount
    Locking
    Speed
    Delayed Locking
    Time Range, sec.
    Holding Strength,
    lbf
    Voltage Range,
    V DC
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Dp.
    Mounting Hardware
    Included
    Electrical
    Connection Type
    Each
    Each
    Each
    Each
    RCI 8375
    Instant30012 to 241 1/2"6 9/16"13/16"1 1/4"5 1/8"3/8"YesHardwire00000000000000000000000000000000000000000000———0
     
    Schlage M420
    Instant50012 to 242 1/2"9"1 1/2"1 3/4"5 5/16"5/8"YesHardwire000000000000000000000000000000000000000000000000000000
     
    Schlage M490P
    Delayed0.5 to 301,50012 to 243"12 1/2"1 3/4"2 1/4"8 3/4"1/2"YesHardwire00000000000000000000000000000000000000000000000000000
     
    Power Converters
    Each
    Wall-Mount AC to DC Power Converter (14" Ht.×12" Wd.×4" Dp.)00000000000000

    Electromagnetic Gate Locks

    Image of ProductInUse. Front orientation. Contains Annotated, Border. Electromagnetic Locks. Electromagnetic Gate Locks.
    Image of Product. Front orientation. Electromagnetic Locks. Electromagnetic Gate Locks, Assa Abloy Securitron.
    Image of Product. Front orientation. Electromagnetic Locks. Electromagnetic Gate Locks, Schlage.

    Assa Abloy

    Securitron

    Schlage

    For use alone or as part of an access-control system, these locks use electromagnets to hold gates closed. Remotely control these locks with a push-button switch or keypad control (sold separately). They lock automatically as soon as the gate is closed. When power is interrupted, these locks instantly release. The electromagnets include wire leads for easy electrical connection.
    Assa Abloy Securitron—Assa Abloy Securitron locks are configurable to either 12V DC or 24V DC. They have a shock-absorbing strike plate that cushions the electromagnet, so the gate and lock won’t be damaged from impact as the gate door closes.
    Schlage—Schlage locks are dual voltage rated for both 12V DC and 24V DC. They don’t require configuration.
    Backup Battery Packs—Backup battery packs supply power for Schlage locks during power interruptions.
    Door Filler Plates—Filler plates are required for Schlage locks if the mounting surface is less than 2" wide.
    Locks
    Backup
    Battery Packs
    Door
    Filler Plates
    Electromagnet
    Strike
    Plate
    Surface Mount
    Locking
    Speed
    Holding Strength,
    lbf
    Voltage Range,
    V DC
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Dp.
    Mounting Fasteners
    Included
    Electrical
    Connection Type
    Each
    Each
    Each
    Assa Abloy Securitron M62FG-SASM
    Instant1,20012 to 248"3"1 3/4"6"2 3/4"1/2"YesHardwire000000000000000———0———0
     
    Schlage M490G
    Instant1,50012 to 2411"3"1 3/4"10 1/2"2 5/8"1"YesHardwire00000000000000000000000000000000000000000
     
    Brackets
    Image of ProductInUse. Sliding Gate. Front orientation. Contains Annotated. Brackets. For Sliding Gate.
    Image of ProductInUse. Swinging Gate. Front orientation. Contains Annotated. Brackets. For Swinging Gate.
    Image of Product. Front orientation. Brackets.

    Sliding Gate

    Swinging Gate

    For Sliding Gate—Sliding brackets attach to doors that glide open horizontally.
    For Swinging Gate—Swinging brackets attach to doors that push and pull.
    For Gate
    Type
    For Mfr.
    For Mfr.
    Series
    For Max.
    Post Wd.
    Mounting Hardware
    Included
    Mounting
    Location
    Each
    SlidingAssa Abloy SecuritronM62FG-SASM3"YesSurface00000000000000
    SwingingAssa Abloy SecuritronM62FG-SASM3"YesSurface00000000000000

    Electromagnetic Locks for Double Doors

    Image of ProductInUse. Front orientation. Contains Annotated. Electromagnetic Locks. Electromagnetic Locks for Double Doors.
    For use alone or as part of an access-control system, these locks use electromagnetic force to hold double doors closed. Control the locks with a push-button switch or keypad door control (sold separately). When power is interrupted, they instantly release. The locks must be hardwired.
    Locks include two strike plates to control two doors at once. They mount under the door frame header and lock the instant doors are closed.
    Backup Battery Packs—Battery backup packs supply power during power interruptions.
    Door Filler Plates—A 5/8" thick filler plate (sold separately) is required if the mounting surface on the frame is less than 2" wide.
    Locks
    Backup
    Battery Packs
    Door
    Filler Plates
    Electromagnet
    Strike
    Plate
    Flush Mount
    Locking
    Speed
    Holding Strength,
    lbf
    Voltage Range,
    V DC
    Ht.
    Wd.
    Dp.
    Ht.
    Lg.
    Dp.
    Mounting Hardware
    Included
    Electrical
    Connection Type
    Each
    Each
    Each
    Schlage M492
    Instant1,50012 to 243"25 1/16"1 3/4"2 1/4"8 3/4"1/2"YesHardwire0000000000000000000000000000000000000000000
     
    Power Converters
    Each
    Wall-Mount AC to DC Power Converter (14" Ht.×12" Wd.×4" Dp.)00000000000000
    back to top