About Brightness
More
About Light Appearance
More
Emergency Backup Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/147/1474k25-@halfx_637112417983601458.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/147/1474k28-@halfx_637112418334018544.png?ver=imagenotfound)
When the power goes out, these lights go on. These backup lights have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Rated for use in damp locations, these lights withstand exposure to humidity and moisture. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Lights with a plastic housing resist corrosion better than lights with a steel housing.
Lights with a steel housing are more durable than lights with a plastic housing. Mount add-on heads in remote areas to extend emergency lighting. Wire up to three of these heads to your emergency backup light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing Material | Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Max. No. of Add-On Heads | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Each | |
Built-In LED Bulbs | ||||||||||||||||
Plastic | 9 3/4" | 4 3/4" | 3 1/8" | 10W | 120V AC, 277V AC | 220 | Cool (5000K) | 2.4W | __ | Yes | 1.5 | No | 4 | 3/16" | 0000000 | 000000 |
Steel | 12 3/8" | 10 1/4" | 2 1/4" | 15W | 120V AC, 277V AC | 600 | Cool (5000K) | 4W | 3 | Yes | 1.5 | No | 4 | 3/16" | 0000000 | 000000 |
Add-On Heads for Steel Housing Lights | 0000000 | Each | 000000 |
Plug-In Emergency Backup Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/160/16035k31-@halfx_637112417986408009.png?ver=imagenotfound)
No need for wiring—these lights plug-in with a two-prong plug. When the power goes out, these lights go on. They have a low-voltage disconnect so they won’t drain the backup battery. The built-in LEDs last longer, are more efficient, and generate less heat than other types of lights.
Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Voltage | Bulbs Included | Brightness, lumens | Light Appearance | Wattage | Plug Type | Cord Lg., ft. | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Each | |
For LED Bulbs | ||||||||||||||||
12 1/8" | 5 1/2" | 3 7/8" | 120V AC | Built-In LED | 1,100 | Daylight (6000K) | 10.8W | Two Prong | 3 | Yes | 1.5 | Yes | 4 | 3/16" | 00000000 | 0000000 |
Wet-Location Emergency Backup Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/929/9296t41-@halfx_637140728407908293.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/929/9296t21p1-h01f-digital@halfx_637063147257742806.png?ver=imagenotfound)
Lights that cannot be sold to California or Oregon are restricted due to energy efficiency requirements.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Batteries Included | Run Time, hrs. | Mounting Hardware Included | Cannot Be Sold To | Each | |
Built-In LED Bulbs | |||||||||||||
7 7/8" | 8" | 2 1/4" | 12W | 120V AC, 277V AC | 300 | Cool (5000K) | 4.1W | Yes | 1.5 | Yes | __ | 0000000 | 0000000 |
8" | 12 1/4" | 3 1/2" | 5W | 120V AC, 277V AC | 100 | Cool (5000K) | 3.75W | Yes | 1.5 | Yes | CA, OR | 0000000 | 000000 |
Emergency-Light Conversion Kits for Fluorescent Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/838/8385k23p1-h01f-digital@halfx_637063057071056727.png?ver=imagenotfound)
Connect the battery pack to your existing fluorescent light to convert it into an emergency backup light. They include a test switch to check that the bulbs and battery are working properly.
Kits that cannot be sold to the regions listed are resitricted by local energy efficiency requirements.
Overall | Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use With | Lg. | Wd. | Ht. | Voltage | Brightness, Lumens | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Cannot Be Sold To | Each | |
For CFL and Fluorescent Bulbs | ||||||||||||
One 4-Pin Twin-Tube CFL Bulb One T8 Fluorescent Bulb (2 ft. to 4 ft.) One T8 U-Shaped Fluorescent Bulb One T9 Circline Fluorescent Bulb One T12 Fluorescent Bulb (2 ft. to 4 ft.) One T12 U-Shaped Fluorescent Bulb | 9 1/2" | 2 1/2" | 1 1/2" | 120V AC, 208V AC, 240V AC, 277V AC | 500 | 1.5 | No | 2 | 5/16" | CA, OR | 0000000 | 0000000 |
One T8 Fluorescent Bulb (5 ft.) One 4-Pin Twin-Tube CFL Bulb One 4-Pin Quad-Tube CFL Bulb One T5 Fluorescent Bulb (2 ft. to 4 ft.) One T5/HO Fluorescent Bulb (2 ft. to 4 ft.) One or Two T8 Fluorescent Bulbs (2 ft. to 4 ft.) One or Two T8 U-Shaped Fluorescent Bulbs One T9 Circline Fluorescent Bulb One or Two T12 Fluorescent Bulbs (2 ft. to 4 ft.) One T12 Fluorescent Bulb (5 ft. to 8 ft.) One T12/HO Fluorescent Bulb (2 ft. to 8 ft.) One T12/VHO Fluorescent Bulb (2 ft. to 8 ft.) One T12 U-Shaped Fluorescent Bulb | 9 3/8" | 2 1/4" | 1 1/4" | 120V AC, 208V AC, 240V AC, 277V AC | 600 | 1.5 | No | 2 | 5/16" | CA, OR | 0000000 | 000000 |
One 4-Pin Twin-Tube CFL Bulb One or Two 4-Pin Quad-Tube CFL Bulbs One T5 Fluorescent Bulb (2 ft. to 4 ft.) One T5/HO Fluorescent Bulb (2 ft. to 4 ft.) One or Two T8 Fluorescent Bulbs (2 ft. to 4 ft.) One or Two T8 Fluorescent Bulbs (5 ft. to 8 ft.) One or Two T8 U-Shaped Fluorescent Bulbs One T9 Circline Fluorescent Bulb One or Two T12 Fluorescent Bulbs (2 ft. to 4 ft.) One or Two T12 Fluorescent Bulbs (5 ft. to 8 ft.) One T12/HO Fluorescent Bulb (2 ft. to 8 ft.) One T12/VHO Fluorescent Bulb (2 ft. to 8 ft.) One or Two T12 U-Shaped Fluorescent Bulbs | 13 3/8" | 2 1/4" | 1 1/4" | 120V AC, 208V AC, 240V AC, 277V AC | 1,400 | 1.5 | No | 2 | 5/16" | __ | 0000000 | 000000 |
Add-On Heads for Emergency Backup Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/147/1474k31@halfx_637140026036060180.png?ver=imagenotfound)
Mount add-on heads in remote areas to extend emergency lighting. Hardwire each head to an emergency backup light; they operate on any of the voltages listed. These add-on heads have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Rated for use in damp locations, these heads withstand exposure to humidity and moisture. Heads adjust to any angle to direct light where needed.
Overall | Head | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Base Dia. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Material | Color | Mounting Hardware Included | Each | |
Built-In LED Bulbs | ||||||||||||
4 5/8" | 7 1/4" | 4 1/2" | 5W | 4.8-12V DC | 45 | Cool (5000K) | 1.25W | Aluminum | White | No | 0000000 | 000000 |
Washdown Emergency Backup Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/836/8369k61-@halfx_637112418333985391.png?ver=imagenotfound)
Rated NEMA 4X, these lights are protected from corrosion and washdowns. They have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Mount add-on heads in remote areas to extend emergency lighting. Wire up to three of these heads to your emergency backup light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Max. No. of Add-On Heads | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Each | |
Built-In LED Bulbs | ||||||||||||||||
10 7/8" | 12" | 6" | 16W | 120V AC, 277V AC | 600 | Cool (5000K) | 8.2W | 3 | Yes | 1.5 | No | 4 | 5/16" | NEMA 4X, IP66 | 0000000 | 0000000 |
Add-On Heads | 0000000 | Each | 000000 |
Hazardous Location Emergency Backup Lights
![](/prerenderstable/mvPRE/contents/gfx/imagecache/159/15955k71-f@halfx_1692018336.png?ver=imagenotfound)
These lights are UL listed for Class I, Division 2, Groups A, B, C, and D for use in environments where ignitable concentrations of hazardous material occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They withstand acetylene, hydrogen, ethylene, and propane. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed. They cannot be sold to the listed areas due to energy efficiency requirements.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Voltage | Bulbs Included | Brightness, lumens | Light Appearance | Max. Wattage per Bulb | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Specifications Met | Cannot Be Sold To | Each | |
For LED Bulbs | ||||||||||||||||
10 5/16" | 16 1/2" | 5 1/2" | 120V AC, 277V AC | Yes | 800 | Cool (5000K) | 5W | Yes | 1.5 | No | 4 | 5/16" | UL Listed | CA, OR, VT | 00000000 | 000000000 |