    Direct-Drive Upblast Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 2.

    Style 1

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    116"2,450 ft³/min @ 1/2 in. H₂O
    2,900 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.1,6253/431 7/8"30 1/2"24 3/4"80300Aluminum
    AMCA Certified, ETL Listed
    000000000000000000000000000000
     
    Totally Enclosed Motor Enclosure
     
    460V AC, Three Phase—Hardwire
    216"3,050 ft³/min @ 0 in. H₂O70 dBA @ 5 ft.1,7501/322"26 3/4"26"51120Steel00000000000000000000000000000
     

    Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    120V AC, Single Phase—3-Blade Plug
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000

    Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Rust won't be a problem with the durable plastic housing and louvers on these fans. The fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Each
    16"2,400Not RatedDirect1,72511/321 1/2"23"24 5/8"24 1/8"23"104FiberglassPolypropylene
    00000000000000

    Direct-Drive Downdraft Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 1.

    Style 1

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Brushless Motor—Fans with a brushless motor are more efficient than fans with a standard motor. They operate at a wide range of speeds for precise speed control and greater energy savings. They’re also quieter and have a longer lifespan because of their advanced electronic controls.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    116"2,600 ft³/min @ 1/2 in. H₂O
    3,100 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.1,4503/433 1/4"23 3/8"24"77120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     
    Totally Enclosed Motor Enclosure—Brushless Motor
     
    120V AC, Single Phase—Hardwire
    116"2,850 ft³/min @ 1/2 in. H₂O
    3,300 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,525133 1/4"23 3/8"24"74120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    16"2,50061 dBA @ 5 ft.Direct1,30011/221 1/4"21 1/4"23 1/2"23 1/2"25 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors

    Belt-Drive Downdraft Roof-Mount Exhaust Fans

    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC/208 to 230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    16"2,800 ft³/min @ 1/2 in. H₂O
    3,200 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.Belt1,14513/433 11/16"29 1/4"26"Aluminum
    Aluminum
    Bird Screen000000000000000000000000000000

    Exterior-Wall-Mount Exhaust Fans

    Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
    Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with an open dripproof (ODP) motor enclosure should be used in clean, dry, and indoor locations. You can use these fans with or without duct. To use them with duct, you'll need an angle ring (not included).
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Grilles—Grilles (sold separately) have fixed blades.
    Louvers—Louvers are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
    Exhaust Fans
    Grilles
    Louvers
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    Each
    16"2,400 ft³/min @ 1/4 in. H₂O
    2,800 ft³/min @ 0 in. H₂O
    56 dBA @ 15 ft.Direct1,07511/314"16"16"34 11/16"30 7/8"180Aluminum
    NoC-UL Listed, UL Listed
    000000000000000000000000000000000000000000

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    16"3,40069 dBA @ 5 ft.Direct1,55013/420 1/8"20 1/8"11 1/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    0000000000000000000000000000

    Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 3

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 3

    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Certification
    Each
    316"2,100Not RatedDirect1,66031/819"19"12"21100SteelAluminum
    UL Recognized Component
    00000000000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    16"2,80061 dBA @ 15 ft.Direct1,72511/320 1/8"20 1/8"15"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000

    Direct-Drive Exhaust Fans

    With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
    208V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    16"3,000 ft³/min @ 1/2 in. H₂O
    3,500 ft³/min @ 0 in. H₂O
    71 dB @ 5 ft.Direct1,650Variable1 1/259 3/4"32 5/8"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    0000000000000000