McMaster-Carr logo
    Filter by
    Mounting Location
    Electrical Phase
    Drive Type
    Base Width
    Blade Material
    Number of Speeds
    Ambient Temperature
    Power Source
    Electrical Connection Type
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    27 Products

    Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    120V AC, Single Phase—3-Blade Plug
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    24"3,950Not RatedDirect1,72011/224 1/2"24 1/2"28"28"17"100SteelAluminum
    No1/4"UL Recognized Component
    000000000000000

    Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.
    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 3

    Style 5

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 3

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    Each
    324"4,80056 dB @ 5 ft.Direct85011/230"30"15 1/2"45104SteelAluminum
    0000000000000000000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 5

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    Each
    524"4,60056 dB @ 5 ft.Direct85011/230"30"15 1/2"70104SteelAluminum
    000000000000000000000000000000
    524"6,80072 dB @ 5 ft.Direct1,7501130"30"12 1/4"78104SteelSteel000000000000000000000000000

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"6,60067 dBA @ 5 ft.Direct1,07513/431 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"5,20069 dBA @ 5 ft.Direct1,12511/231 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    24"6,60067 dBA @ 5 ft.Direct1,07513/430 1/8"30 1/8"11 1/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    0000000000000000000000000000
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. 120V AC. Direct-Drive Wall-Mount Exhaust Fans .
    Louvers—Fans with louvers create a weather-tight seal when they're turned off. The louvers open automatically on startup and spring closed when not in use.
    Hoods—Hoods (sold separately) help extend the life of your exhaust fan by protecting it from harsh weather, such as severe wind, and debris.
    Exhaust Fans
    Hoods
    For
    Opening
    Overall
    Mounting
    Hole
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Dia.
    Location
    No.
    of
    Includes
    Each
    Each
    24"4,800Not RatedDirect1,72511/225 1/4"25 1/4"28 1/4"28 1/4"20 3/4"100Galvanized SteelAluminum
    3/16"Frame4Louvers00000000000000000000000000000

    Direct-Drive Upblast Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 2.

    Style 1

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    208 to 230V AC, Three Phase—Hardwire
    124"7,000 ft³/min @ 1/2 in. H₂O
    7,750 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.900341 7/8"37 1/2"33"312300Aluminum
    AMCA Certified, ETL Listed
    000000000000000000000000000000
     
    Totally Enclosed Motor Enclosure
     
    460V AC, Three Phase—Hardwire
    224"7,400 ft³/min @ 0 in. H₂O66 dBA @ 5 ft.1,7503/430"20 3/4"36"208120Steel0000000000000000000000000000
     

    Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Rust won't be a problem with the durable plastic housing and louvers on these fans. The fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Each
    24"4,700Not RatedDirect1,70011/231 1/2"31 1/2"34 3/8"34 1/2"27 1/2"104FiberglassPolypropylene
    00000000000000

    Exterior-Wall-Mount Exhaust Fans

    Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
    Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Totally Enclosed Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Includes
    Each
    24"5,300 ft³/min @ 0.2 in. H₂O
    7,300 ft³/min @ 0 in. H₂O
    Not RatedDirect1,72511/224"31 1/2"31 1/2"34 1/2"45"104PlasticNoLouvers0000000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Totally Enclosed Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Includes
    Each
    24"4,400 ft³/min @ 0.2 in. H₂O
    5,800 ft³/min @ 0 in. H₂O
    Not RatedDirect1,72031/224"31 1/2"31 1/2"34 1/2"45"104Aluminum
    NoLouvers0000000000000000

    Belt-Drive Downdraft Roof-Mount Exhaust Fans

    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    24"6,900 ft³/min @ 1/2 in. H₂O
    7,750 ft³/min @ 0 in. H₂O
    73 dBA @ 5 ft.Belt8751244 1/4"39 11/16"33"Aluminum
    Aluminum
    Bird Screen000000000000000000000000000000

    Hazardous Location Upblast Roof-Mount Exhaust Fans

    With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
    Direct Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,900 ft³/min @ 1/2 in. H₂O
    6,900 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,1503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    000000000000000000000000000000
     
    Belt Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,530 ft³/min @ 1/2 in. H₂O
    6,150 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,7503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    000000000000000000000000000000
     

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    24"6,50071 dBA @ 5 ft.Direct1,12513/430 1/8"30 1/8"29 1/8"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D
    000000000000000000000000000000

    Direct-Drive Downdraft Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 2.

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    208/230V AC Three Phase—Hardwire
    224"8,100 ft³/min @ 1/2 in. H₂O
    9,000 ft³/min @ 0 in. H₂O
    73 dBA @ 5 ft.925343 7/16"37 1/4"33"288120Aluminum
    AMCA Certified, ETL Listed
    000000000000000000000000000000
     
    back to top