    Hazardous Location Upblast Roof-Mount Exhaust Fans

    With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
    Direct Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,900 ft³/min @ 1/2 in. H₂O
    6,900 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,1503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N110000000002230K660000000
    30"5,900 ft³/min @ 1/2 in. H₂O
    9,350 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.1,150139"28"42"370100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N12000000002230K45000000
     
    240/460V AC, Three Phase—Hardwire
    36"15,700 ft³/min @ 1/2 in. H₂O
    21,000 ft³/min @ 0 in. H₂O
    79 dBA @ 5 ft.1,150345"31"48"480100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N13000000002230K48000000
    42"19,400 ft³/min @ 1/2 in. H₂O
    25,300 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,150351"34"54"520100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N14000000002230K49000000
    48"31,600 ft³/min @ 1/2 in. H₂O
    36,200 ft³/min @ 0 in. H₂O
    89 dBA @ 5 ft.1,1507 1/257"37"60"670100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N15000000002230K26000000
     
    Belt Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,530 ft³/min @ 1/2 in. H₂O
    6,150 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,7503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N210000000002230K660000000
    30"2,950 ft³/min @ 1/2 in. H₂O
    9,800 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,7503/439"28"42"410100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N22000000002230K45000000
     
    240/460V AC, Three Phase—Hardwire
    36"20,200 ft³/min @ 1/2 in. H₂O
    24,100 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,750545"31"48"590100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N23000000002230K48000000
    42"22,400 ft³/min @ 1/2 in. H₂O
    27,800 ft³/min @ 0 in. H₂O
    78 dBA @ 5 ft.1,750551"34"54"720100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N24000000002230K49000000
    48"28,600 ft³/min @ 1/2 in. H₂O
    36,700 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,750557"37"60"840100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N25000000002230K26000000
     

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Belt Drive—Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged. They come with collars, so you can connect these fans to a louver.
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Includes
    Each
    30"9,84071 dBA @ 10 ft.Belt1,72513/434 3/4"34 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar2208K11000000000
    36"11,00072 dBA @ 10 ft.Belt1,72513/440 3/4"40 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar2208K1200000000
    42"14,60074 dBA @ 10 ft.Belt1,72513/446 3/4"46 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar2208K1300000000
    48"19,10070 dBA @ 10 ft.Belt1,72513/452 3/4"52 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar2208K1400000000

    High-Flow Low-Pressure Hazardous Location Compressed Air Blowers

    Safely produce high-flow compressed air with low pressure or vacuum in environments with flammable gases and combustible dust, such as propane and carbon-based dust. These blowers have an explosion-proof motor and are UL listed for use in hazardous locations. Also known as regenerative blowers, they are commonly used to operate pump drives, lift tables, and conveying systems. They can also be used for drying, exhausting, and aerating.
    Single Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Hazardous Location Compressed Air Blowers.
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Hazardous Location Rating
    Each
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    2 psi
    50 in. H₂O
    556 ft³/min @ 0 psi3.7 in. Hg
    50 in. H₂O
    1024.3 amp @ 208V AC
    22.4 amp @ 230V AC
    11.2 amp @ 460V AC
    8125"20"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K74000000000
    2 psi
    60 in. H₂O
    471 ft³/min @ 0 psi4.4 in. Hg
    59 in. H₂O
    1024.3 amp @ 208V AC
    22.4 amp @ 230V AC
    11.2 amp @ 460V AC
    8125"19"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7300000000
    2 psi
    68 in. H₂O
    381 ft³/min @ 0 psi5 in. Hg
    67 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    8023"18"19"5 to 1003
    3
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7200000000
    4 psi
    116 in. H₂O
    294 ft³/min @ 0 psi8.8 in. Hg
    119 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    8023"16"19"5 to 1003
    3
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7100000000
     
    Two Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Hazardous Location Compressed Air Blowers.
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Hazardous Location Rating
    Each
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    3 psi
    110 in. H₂O
    220 ft³/min @ 0 psi8.1 in. Hg
    110 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    7827"19"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K77000000000
    4 psi
    115 in. H₂O
    274 ft³/min @ 0 psi8.5 in. Hg
    115 in. H₂O
    1024.3 amp @ 208V AC
    22.4 amp @ 230V AC
    11.2 amp @ 460V AC
    8127"20"22"5 to 1004
    4
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7800000000
    5 psi
    150 in. H₂O
    167 ft³/min @ 0 psi11 in. Hg
    149 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    7723"18"19"5 to 1002
    2
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7600000000
    8 psi
    240 in. H₂O
    128 ft³/min @ 0 psi11.9 in. Hg
    161 in. H₂O
    7 1/218.9 amp @ 208V AC
    17.8 amp @ 230V AC
    8.9 amp @ 460V AC
    7527"16"19"5 to 1002
    2
    NEC Class I Divisions 1, 2 Group D
    NEC Class II Division 2 Groups F, G
    4393K7500000000
     