    Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    10"680Not RatedDirect1,56031/1210 1/2"10 1/2"13"13"8 1/8"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K320000000
    12"825Not RatedDirect1,56031/1212 1/2"12 1/2"15"15"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K21000000
    14"1,520Not RatedDirect1,66031/814 1/2"14 1/2"17"17"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K43000000
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K22000000
    18"2,300Not RatedDirect1,66031/818 1/2"18 1/2"21"21"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K33000000
    20"2,925Not RatedDirect1,14021/420 1/2"20 1/2"23"23"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K25000000
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K23000000
    30"3,950Not RatedDirect1,14021/430 1/2"30 1/2"33"33"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K24000000
    120V AC, Single Phase—3-Blade Plug
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    10"680Not RatedDirect1,56031/1210 1/2"10 1/2"13"13"8 1/8"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K410000000
    12"825Not RatedDirect1,56031/1212 1/2"12 1/2"15"15"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K42000000
    14"1,520Not RatedDirect1,66031/814 1/2"14 1/2"17"17"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K44000000
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K45000000
    18"2,300Not RatedDirect1,66031/818 1/2"18 1/2"21"21"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K46000000
    20"2,925Not RatedDirect1,14021/420 1/2"20 1/2"23"23"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K47000000
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K48000000
    30"3,950Not RatedDirect1,14021/430 1/2"30 1/2"33"33"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K49000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    20"2,820Not RatedDirect1,72011/320 1/2"20 1/2"23"23"12 1/2"100SteelAluminum
    No1/4"UL Recognized Component
    19455K260000000
    24"3,950Not RatedDirect1,72011/224 1/2"24 1/2"28"28"17"100SteelAluminum
    No1/4"UL Recognized Component
    19455K31000000
    30"5,745Not RatedDirect85011/230 1/2"30 1/2"33"33"15 1/4"100SteelAluminum
    No1/4"UL Recognized Component
    19455K27000000

    Roof-Mount Louvers

    These louvers are gravity operated. The blades open when your roof-mounted exhaust fan goes on and close when it's off, preventing backdrafts. The felt seal on the face of the blades ensures quiet closing and better protection from the weather.
    Also Available: Additional louver sizes. Please select 8061T999 and specify louver dimensions.
    Surface Mount
    Image of Product. Front orientation. Louvers. Roof-Mount Louvers.
    Image of Specification. Side1 orientation. Surface Mount.
    Image of Product. Front orientation. Exhaust Fan Mounts.
    Image of Attribute. Front orientation. CrossSection view. Contains Annotated.

    Surface

    Mount

    Exhaust Fan Mounts

    Exhaust Fan Mounts—Exhaust fan mounts are sold separately. Louvers fit the bottom of the mount and must be secured to the lip of the mount's base with sheet metal screws (not included).
    Louvers
    8" High Exhaust
    Fan Mounts
    12" High Exhaust
    Fan Mounts
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Lg.
    Blade
    Thk.
    No. of
    Panels
    For Max. Air
    Velocity, fpm
    Temp. Range,
    ° F
    Mounting Fasteners
    Included
    Each
    Inside
    Wd.
    Each
    Inside
    Wd.
    Each
    Galvanized Steel Frame and Aluminum Blades
    13 3/4"13 3/4"13 3/4"13 3/4"0.016"12,000-40 to 180No8061T300000014 1/2"2230K11000000014 1/2"2230K640000000
    15 3/4"15 3/4"15 3/4"15 3/4"0.016"12,000-40 to 180No8061T50000016 1/2"2230K1300000016 1/2"2230K31000000
    17 3/4"17 3/4"17 3/4"17 3/4"0.016"12,000-40 to 180No8061T900000———019 1/2"2230K33000000
    19 3/4"19 3/4"19 3/4"19 3/4"0.016"12,000-40 to 180No8061T140000021 1/2"2230K16000000———0
    21 3/4"21 3/4"21 3/4"21 3/4"0.016"12,000-40 to 180No8061T1600000———023 1/2"2230K35000000
    23 3/4"23 3/4"23 3/4"23 3/4"0.016"12,000-40 to 180No8061T1900000———025 1/2"2230K36000000
    27 3/4"27 3/4"27 3/4"27 3/4"0.016"12,000-40 to 180No8061T26000000———028 1/2"2230K39000000
    34 3/4"34 3/4"34 3/4"34 3/4"0.016"12,000-40 to 180No8061T2800000035 1/2"2230K6300000035 1/2"2230K94000000
    36 3/4"36 3/4"36 3/4"36 3/4"0.016"12,000-40 to 180No8061T29000000———037 1/2"2230K45000000
     
    Motor Kits for Louvers with Galvanized Steel Frames

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    10"87056 dBA @ 5 ft.Direct1,55011/2017 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K18000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/817 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K1900000000
    16"2,50061 dBA @ 5 ft.Direct1,30011/221 1/4"21 1/4"23 1/2"23 1/2"25 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K2400000000
    18"3,80065 dBA @ 5 ft.Direct1,30013/425 1/4"25 1/4"27 1/2"27 1/2"26 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K2500000000
    24"6,60067 dBA @ 5 ft.Direct1,07513/431 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K2600000000
    Replacement Fan Motors
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"5,20069 dBA @ 5 ft.Direct1,12511/231 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K27000000000
    Replacement Fan Motors
    230/460V AC, Three Phase—Hardwire
    Cannot Be Sold to California—Fans that cannot be sold to California are restricted by local energy efficiency requirements.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Cannot Be
    Sold To
    Each
    30"8,40074 dBA @ 5 ft.Direct1,1251137 1/4"37 1/4"39 1/2"39 1/2"27 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California19105K31000000000
    36"12,30074 dBA @ 5 ft.Direct85011 1/243 1/4"43 1/4"45 1/2"45 1/2"31 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California19105K4200000000

    Belt-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans with Louvers .
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"19"152104SteelSteelSteelNo3/16"2101K12000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"19"121104SteelSteelSteelNo3/16"2101K1300000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"19"270104SteelSteelSteelNo3/16"2101K1400000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"19"266104SteelSteelSteelNo3/16"2101K1500000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"25"153104SteelSteelSteelNo3/16"2101K22000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"25"225104SteelSteelSteelNo3/16"2101K2300000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"25"250104SteelSteelSteelNo3/16"2101K2400000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"25"324104SteelSteelSteelNo3/16"2101K2500000000
    Replacements for Exhaust Fans

    Exterior-Wall-Mount Exhaust Fans

    Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
    Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with an open dripproof (ODP) motor enclosure should be used in clean, dry, and indoor locations. You can use these fans with or without duct. To use them with duct, you'll need an angle ring (not included).
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Grilles—Grilles (sold separately) have fixed blades.
    Louvers—Louvers are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
    Exhaust Fans
    Grilles
    Louvers
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    Each
    7"190 ft³/min @ 0 in. H₂O39 dBA @ 15 ft.Direct1,05011/258"8"8"17 1/8"13"180Aluminum
    NoC-UL Listed, UL Listed
    1925K100000001925K810000001925K91000000
    10"250 ft³/min @ 1/4 in. H₂O
    550 ft³/min @ 0 in. H₂O
    42 dBA @ 15 ft.Direct1,05011/2510"10"10"21 1/8"16"180Aluminum
    NoC-UL Listed, UL Listed
    1925K20000001925K82000001925K9200000
    13"1,400 ft³/min @ 1/4 in. H₂O
    1,600 ft³/min @ 0 in. H₂O
    49 dBA @ 15 ft.Direct1,07511/612"12"12"30 3/16"28 3/4"180Aluminum
    NoC-UL Listed, UL Listed
    1925K40000001925K84000001925K9300000
    16"2,400 ft³/min @ 1/4 in. H₂O
    2,800 ft³/min @ 0 in. H₂O
    56 dBA @ 15 ft.Direct1,07511/314"16"16"34 11/16"30 7/8"180Aluminum
    NoC-UL Listed, UL Listed
    1925K5000000001925K850000001925K9400000
    120/230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with an open dripproof (ODP) motor enclosure should be used in clean, dry, and indoor locations. You can use these fans with or without duct. To use them with duct, you'll need an angle ring (not included).
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Grilles—Grilles (sold separately) have fixed blades.
    Louvers—Louvers are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
    Exhaust Fans
    Grilles
    Louvers
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    Each
    18"4,000 ft³/min @ 1/4 in. H₂O
    4,300 ft³/min @ 0 in. H₂O
    58 dBA @ 15 ft.Direct1,12513/420"20"20"39 7/16"35 5/8"180Aluminum
    NoC-UL Listed, UL Listed
    1925K620000000001925K8700000001925K970000000
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Totally Enclosed Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Belt Drive—Belt-drive fans are quieter than direct-drive fans. They also last longer because their components can be replaced if damaged.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Includes
    Each
    20"4,000 ft³/min @ 0.2 in. H₂O
    5,000 ft³/min @ 0 in. H₂O
    Not RatedDirect1,72511/320"25 3/4"25 3/4"29 1/2"40"104PlasticNoLouvers1925K630000000
    24"5,300 ft³/min @ 0.2 in. H₂O
    7,300 ft³/min @ 0 in. H₂O
    Not RatedDirect1,72511/224"31 1/2"31 1/2"34 1/2"45"104PlasticNoLouvers1925K6400000000
    36"5,800 ft³/min @ 0.2 in. H₂O
    10,500 ft³/min @ 0 in. H₂O
    Not RatedDirect82511/236"44"44"53"57"104PlasticNoLouvers1925K6500000000
    50"12,100 ft³/min @ 0 in. H₂O
    16,200 ft³/min @ 0.2 in. H₂O
    Not RatedBelt1,7251150"56"56"63"47 1/4"104SteelNoLouvers1925K6600000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Totally Enclosed Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Belt Drive—Belt-drive fans are quieter than direct-drive fans. They also last longer because their components can be replaced if damaged.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Includes
    Each
    24"4,400 ft³/min @ 0.2 in. H₂O
    5,800 ft³/min @ 0 in. H₂O
    Not RatedDirect1,72031/224"31 1/2"31 1/2"34 1/2"45"104Aluminum
    NoLouvers1925K67000000000
    36"6,700 ft³/min @ 0.2 in. H₂O
    11,200 ft³/min @ 0 in. H₂O
    Not RatedDirect82531/236"44"44"53"57"104SteelNoLouvers1925K6800000000
    50"12,100 ft³/min @ 0.2 in. H₂O
    21,600 ft³/min @ 0 in. H₂O
    Not RatedBelt80031/250"56"56"63"47 1/4"104SteelNoLouvers1925K6900000000

    Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Rust won't be a problem with the durable plastic housing and louvers on these fans. The fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Each
    12"1,300Not RatedDirect1,70011/317 1/2"18 1/2"21 1/4"20 3/4"20 5/8"104FiberglassPolypropylene
    6658T810000000
    16"2,400Not RatedDirect1,72511/321 1/2"23"24 5/8"24 1/8"23"104FiberglassPolypropylene
    6658T82000000
    20"3,100Not RatedDirect1,70011/325 3/4"25 3/4"28 1/4"28 3/4"25 1/2"104FiberglassPolypropylene
    6658T83000000
    24"4,700Not RatedDirect1,70011/231 1/2"31 1/2"34 3/8"34 1/2"27 1/2"104FiberglassPolypropylene
    6658T84000000