About Wire and Cable
More
Micro M12 Cords
The threaded ends on these cords seal out contaminants and resist coming loose from vibration in tough industrial environments and automated systems while sending power and signal to devices with M12 connections. Poles and keyways on the connector face adhere to standard coding layouts, reducing the chance of mismatching connections during setup.
A-coded cords work with AC and DC sensors, actuators, motors, light curtains, and other devices. They’re also often used to connect equipment to IO Link controllers and within Profibus, DeviceNet, and other fieldbus systems.
Cords with PVC insulation work well in general purpose applications, but they shouldn’t be used outdoors. While flexible, these cords aren’t as flexible as cords with polyurethane or TPE insulation, making them best for stationary jobs.
Use unshielded cords in applications where signal interference isn’t a concern.
Cords with a 90° elbow run along the side of equipment, so they fit behind machines and in tight spaces.
When mated, the connectors are IP rated to block out dust and water if briefly submersed. IP66K rated connectors can be sprayed down during high-pressure washdowns.
Add caps to protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.




Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Temp. Range, °F | Shielding | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | |||||||||||||||
4 | A | 0.3" | 1/2 | 4 | 30V AC/30V DC | M12 | 22 | 0.2" | PVC Plastic | -10° to 185° | Unshielded | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 000000 | 000000 |
5 | A | 0.3" | 1/2 | 4 | 30V AC/30V DC | M12 | 22 | 0.2" | PVC Plastic | -10° to 185° | Unshielded | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | |||||||||||||||
4 | A | 0.3" | 1/2 | 4 | 30V AC/30V DC | M12 | 22 | 0.2" | PVC Plastic | -10° to 185° | Unshielded | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
5 | A | 0.3" | 1/2 | 4 | 30V AC/30V DC | M12 | 22 | 0.2" | PVC Plastic | -10° to 185° | Unshielded | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
Mini Cords
With a higher maximum current than nano M8 and micro M12 cords, these mini cords are often used with automated systems, motors, and pumps. A threaded housing securely mates with other mini connections and won’t shake loose from vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors. These cords are unshielded, so they’re best for use where signal interference is not a concern.
When mated, these cords meet IP ratings for protection from dust and temporary submersion.
Thread adapters connect plugs and sockets that both have internal threads.
Caps protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.




Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Temp. Range, °F | Shielding | Specifications Met | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||
3 | 0.875" | 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
4 | 0.875" | 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | ||||||||||||||
3 | 0.875" | 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |

Thread Size | Material | Each | |
External Thread | |||
---|---|---|---|
7/8"-16 | Aluminum | 00000000 | 00000 |
For Face Dia. | Thread Size | Material | Includes | Each | |
External Thread | |||||
---|---|---|---|---|---|
0.55" | 7/8"-16 | Epoxy-Coated Zinc | Lanyard | 00000000 | 000000 |
Nano M8 Cords




Also known as pico cords, these cords are often used with low-current 8 mm proximity and photoelectric switches.
Cords with 90° elbow plugs and sockets fit flush against equipment, so they fit in tight spaces.
All are rated IP67 for protection from dust and temporary submersion. Cords rated IP66K also protect against washdowns.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Color | Shielding | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
3 | A | 0.2" | 1/2 | 4 | 30V AC/30V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | -20° to 175° | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 000000 |
4 | A | 0.2" | 1/2 | 4 | 30V AC/30V DC | M8 | 24 | 0.19" | PVC Plastic | Yellow | Unshielded | -20° to 175° | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | ||||||||||||||||
3 | A | 0.2" | 1/2 | 4 | 30V AC/30V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | -20° to 175° | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
4 | A | 0.2" | 1/2 | 4 | 30V AC/30V DC | M8 | 24 | 0.19" | PVC Plastic | Yellow | Unshielded | -20° to 175° | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
Solenoid Valve Cords
Use these cords with hydraulic and air-powered valves, motors, pumps, and pressure switches. They have a solenoid valve socket on one end and an M12 threaded plug on the other. The ground connection is not included in the number of poles. A power-indicating light on the socket illuminates when the cord has power. All are IP-rated for protection from washdowns and temporary submersion.
For technical drawings and 3-D models, click on a part number.

Socket | Plug | Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DIN Type | Contact Distance | Housing Thread Size | Coding | No. of Poles | No. of Ground Connections | Lg., ft. | Wire Gauge | Current, A | Voltage | OD | Insulation Material | Environmental Rating | Specifications Met | Each | |
90° Elbow Socket × Plug (External Thread) | |||||||||||||||
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 000000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |

For Thread Size | Material | Includes | Each | |
For Plugs | ||||
---|---|---|---|---|
M12 | Anodized Aluminum | Lanyard | 0000000 | 000000 |
Interference-Limiting Outlet Strips
Filters between the outlets on these strips protect computers and other sensitive equipment from external signals that interfere with the equipment’s performance. A circuit breaker prevents damage from current overload and short circuits. Surge suppression protects devices from voltage spikes. The surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.



No. of Outlets | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Surge Rating | Material | Protection Type | Circuit Breaker Trip Current, A | Specifications Met | Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | 3330J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 000000 |
6 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | 3300J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 00000 |
Bench-Top Outlet Strips

Mount these outlet strips to a desktop or workbench with the mounting hardware, or set them on a surface. The outlets have internal shutters to prevent the insertion of foreign objects. These outlet strips have a 90° elbow plug that fits flush against a wall outlet, so they fit behind machinery or in areas where space is tight. The plug also has an outlet on the back to connect equipment. Use the USB ports to charge mobile devices.
For technical drawings and 3-D models, click on a part number.




No. of Outlets | Outlet Ctr.-to-Ctr. | USB Connection Type (No. of Ports) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Specifications Met | Choose a Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3 | 1 1/8" | A (1) C (1) | 6 | 15 | 120V AC | Internal Shutters, Three-Prong Outlet | Polycarbonate Plastic | ETL Listed, C-ETL Listed | 0000000 | 0000000 |
Shielded Panel-Mount Ethernet Cords
Often used in labs, storage facilities, and offices, the shielding blocks low to moderate signal interference from nearby equipment and devices. These cords have a flange on the socket end to mount them in a panel cutout. They send data between computers, printers, servers, and switches. For faster data transmission speeds, choose a cord with a higher ethernet cable category. All are backward compatible, so they work in networks that meet the same or a lower category.
Screw-in cords simply thread into panel cutouts. Use them on panels that are 1.5 mm to 5 mm thick.
Add an optional cap to protect the end of screw-in cords when not in use. Hinged caps open and shut quickly at a fixed angle, so they’re more convenient for frequent access than tethered caps. Tethered caps can open in any direction, letting you access the end of the cord from any angle.
Label holders (sold separately) snap onto the end of the cords.
For technical drawings and 3-D models, click on a part number.



Ethernet Cords | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting | Labels | Label Holders | ||||||||||||||
Lg., ft. | Transmission Frequency | Wire Gauge | Cord OD | Shield Type | Temperature Range, °F | For Panel Cutout Dia. | Thread Size | Thread Pitch, mm | Color | Connection End Color | Each | Each | Each | |||
RJ45 Plug × RJ45 Socket | ||||||||||||||||
Ethernet Cable Category 6 | ||||||||||||||||
1/2 | 250 MHz | 26 | 0.24" | Foil | -10° to 155° | 0.88" | M22 | 1.5 | Yellow | Black | 0000000 | 000000 | 000000 | 00000 | 000000 | 00000 |
1/2 | 250 MHz | 26 | 0.24" | Foil | -10° to 155° | 0.88" | M22 | 1.5 | Yellow | Silver | 0000000 | 00000 | 000000 | 0000 | 000000 | 0000 |
For Panel Cutout Diameter | Environment | Environmental Rating | Cap Type | Material | Color | Each | |
Hinged | |||||||
---|---|---|---|---|---|---|---|
0.88" | __ | IP40 | Snap On | Plastic | Clear | 0000000 | 000000 |
0.88" | Submersible | IP65, IP67 | Snap On | Plastic | Black | 0000000 | 00000 |
0.88" | Submersible | IP65, IP67 | Snap On | Plastic | Clear | 0000000 | 00000 |
Tethered | |||||||
0.88" | Submersible | IP65, IP67 | Snap On | Rubber | Black | 000000 | 0000 |
USB Cords
Connect devices such as computers, printers, and mobile devices. The higher the USB standard, the faster cords can transmit data. These cords are backward compatible, so they work with cords and connectors that meet the same or lower USB standard.
90° elbow cords fit flush against equipment so they fit in tight spaces.

Lg., ft. | Shielding | Color | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | ||||
---|---|---|---|---|
1/2 | Unshielded | Black | 00000000 | 000000 |
USB Adapter Cords
Adapt your USB port to connect to a variety of other devices. These USB cords are backward compatible, so they work with cords and connectors that meet the same or a lower USB standard.
Double-shielded cords have insulation, so they reduce signal interference from nearby equipment and devices.
For technical drawings and 3-D models, click on a part number.

Length | Application | Shielding | Shield Type | Color | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | ||||||
---|---|---|---|---|---|---|
6" | Data/Video | Double Shielded | Braid, Foil | Black | 0000000 | 000000 |

Length | Application | Shielding | Shield Type | Color | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | ||||||
---|---|---|---|---|---|---|
6" | Data/Video | Double Shielded | Braid, Foil | Black | 0000000 | 000000 |

Length | Application | For Cable Industry Designation | Shielding | Color | Includes | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | |||||||
---|---|---|---|---|---|---|---|
6" | Data | Single Mode OS1, Single Mode OS2 | Unshielded | White | Driver CD | 0000000 | 0000000 |
Audio Equipment Cord Splitters

Play audio from one source on two different speakers. These splitters have shielding to block signal interference from nearby equipment and devices.
Stereo Connection | |||||||
---|---|---|---|---|---|---|---|
Lg. | Plug Size, mm | Socket Size, mm | Cord OD | Shield Type | Color | Each | |
Plug × Socket | |||||||
6" | 3.5 | 3.5 | 0.12" | Braid, Foil | White | 0000000 | 00000 |
Latching Connectors
Protect connections while maintaining access. The base and hood latch together securely yet can be quickly detached for equipment repair or replacement.
Latching connectors with one latching lever quickly disconnect with one hand.
NEMA 4X rated connectors protect against washdowns. NEMA 12 rated connectors resist oil/coolant dripping. IP65 rated connectors protect against dust and rinsing.
For technical drawings and 3-D models, click on a part number.

Conduit | Connectors | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Environmental Rating | Each | |
Powder-Coated Aluminum | ||||||||||||||
48 | 600V AC/600V DC | 16A | 1 1/4 | NPT | Screw Terminals | 18-14 | 6.5" | 3.8" | 5.4" | Attached | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |

Conduit | Connectors | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Environmental Rating | Each | |
Powder-Coated Aluminum | ||||||||||||||
48 | 600V AC/600V DC | 16A | 1 1/4 | NPT | Screw Terminals | 18-14 | 6.5" | 3.8" | 5.4" | Attached | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |
Harsh Environment Latching Connectors

Rated NEMA 4X, 12, and IP65, connectors protect against corrosion, washdowns, oil/coolant dripping, and water projected from a nozzle. They have a rubber seal and stainless steel hardware for excellent chemical resistance. Use them to protect connections while maintaining access. The base and hood latch together securely, yet can be quickly detached for equipment repair or replacement.
For technical drawings and 3-D models, click on a part number.
Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Connection Gender | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Environmental Rating | Each | |
Side Conduit Connection—1 Latching Lever | |||||||||||||||
Powder-Coated Aluminum | |||||||||||||||
48 | 600V AC/600V DC | 16A | 1 1/4 | NPT | Female | Screw Terminals | 18-14 | 6.5" | 3.8" | 5.4" | Attached | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |
Flat Flexible Cable
- Temperature Range: -40° to 220° F
Made of thin, flattened wires, this flexible cable can be routed in tight spaces, such as inside a laptop. Connect it to your circuit board with flat flexible cable connectors (not included).
For technical drawings and 3-D models, click on a part number.
![]() | ![]() Front |
![]() Back |
Contact | 6" Lg. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Wires | Current | Wd. | Thick. | Lg. | Ctr.-to-Ctr., mm | Outer Insulation Color | Specifications Met | Pkg. Qty. | Pkg. | |
Solid Wire | ||||||||||
60V AC | ||||||||||
4 | 1.25 A @ 86° F | 0.2" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |
6 | 1.25 A @ 86° F | 0.28" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 0000 |
8 | 1.25 A @ 86° F | 0.35" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |
10 | 1.25 A @ 86° F | 0.43" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |
12 | 1.25 A @ 86° F | 0.51" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |



Contact | 6" Lg. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Wires | Current | Wd. | Thick. | Lg. | Ctr.-to-Ctr., mm | Outer Insulation Color | Specifications Met | Pkg. Qty. | Pkg. | |
Solid Wire | ||||||||||
60V AC | ||||||||||
4 | 1.25 A @ 86° F | 0.2" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |
6 | 1.25 A @ 86° F | 0.28" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 0000 |
8 | 1.25 A @ 86° F | 0.35" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |
10 | 1.25 A @ 86° F | 0.43" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |
12 | 1.25 A @ 86° F | 0.51" | 0.01" | 0.16" | 1 | White | UL 2556 VW-1 | 5 | 0000000 | 00000 |