Find the right lumen level to brighten your space. Then, compare the way warm, neutral, and cool lighting affect the appearance of everyday objects.
About Hazardous Location Environmental Ratings
More
About Replacing Tubular Fluorescent Light Bulbs
More
Wraparound-Lens Ceiling Lights

Light diffuses evenly from the sides and bottom to produce ambient lighting. These fixtures are ideal for offices, storage rooms, and other indoor spaces. Rated for use in damp locations, they withstand humidity and moisture.
Style B have a traditional look to match your existing lights. Their prismatic acrylic lens produces the widest beam and reduces glare better than smooth lenses. When installing a long row of lights, use the knockouts to connect to conduit and hardwire the lights together.
Add a motion sensor (sold separately) to automatically turn lights on when people or vehicles are present.
Add suspension hardware (sold separately) for an alternative to surface mounting.

Lights | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Housing | Motion Sensors | 2 1/2 to 5 ft. Suspension Hardware | 2 1/2 to 10 ft. Suspension Hardware | ||||||||||||||||
| Lg. | Wd. | Ht. | Brightness, lumens | Wattage | Voltage | Light Appearance | Light Setting | Material | Color | Mounting Hardware Included | Mounting Hole Diameter (No. of) | Specifications Met | Each | Each | Pkg. | Pkg. | ||||
Prismatic Semi-Clear Acrylic Plastic Lens | ||||||||||||||||||||
| 48" | 10" | 2 3/4" | 4,200 | 32W | 120-277V AC | Neutral (4,000K) | Dimmable | Steel | White | No | 7/8" (3), 11/16" (2) | CSA Certified | 1619K68 | 0000000 | 8442K114 | 000000 | 2338N1 | 000000 | 2338N2 | 000000 |
Washdown Ceiling Lights
IP or NEMA rated, these lights have a sealed lens to keep dust and moisture out for protection against washdowns. All meet ETL or UL standards for wet locations.
Mount these lights to the ceiling with the included brackets. For lights with mounting V-hooks, you can suspend them from the ceiling with chains (not included).
Styles A-B have a wraparound lens that allows light to shine from the sides as well as the bottom. IP66 lights withstand high-pressure washdowns. NEMA 4X lights withstand corrosive liquids and spraying water—including washdowns.
Lights that meet NSF/ANSI 2 standards are commonly used in food handling and processing areas with splashing liquid.

Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Lg. | Wd. | Ht. | Brightness, lumens | Wattage | Voltage | Electrical Connection Type | Light Appearance | Light Setting | Mounting Hardware Included | Includes | Environmental Rating | Specifications Met | Each | |
Made Outside the U.S. | |||||||||||||||
Built-In LED | |||||||||||||||
| B | 47 1/2" | 3 7/8" | 3 3/4" | 2,800 4,200 5,600 | 22W 32W 46W | 120-347V AC | Hardwire | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP66, NEMA 4X | UL Listed, DLC Listed, NSF/ANSI 2 Splash Zone | 1616K345 | 0000000 |
Explosion-Proof Ceiling Lights

Contain explosions, sparks, and flashes—the enclosure on these ceiling lights makes them safe to use in NEC Class I and II, Division 1 hazardous locations. They meet NEC hazardous location temperature classifications, so their surface stays cool enough to avoid igniting hazardous gases or dust. Designed to resist corrosion from salt water, they’re also UL marine listed. All lights have adjustable mounting brackets that can rotate 45° in either direction to direct light where you need it.
Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Lg. | Wd. | Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Housing Material | Mounting Hardware Included | Environmental Rating | NEC Hazardous Location Temperature Classification | Specifications Met | Each | |
Built-In LED | ||||||||||||||
| 2 | 27 1/2" | 12" | 9" | 4,200 | Cool (5,000K) | 40W | 120-277V AC | Aluminum | No | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | T6-T3B (185° - 329° F) | UL Listed, UL Marine Listed, C-UL Listed | 8257N11 | 000000000 |
Landscape Lights

Illuminate outdoor areas such as building grounds and entrance signs with a narrow beam of directed light. Heads adjust to direct light where needed.
Lights with a cool light appearance highlight white/blue tones creating good visibility at night.
Style A have built-in LEDs that last longer, are more efficient, and generate less heat than other technologies. These fixtures can be set to cool or neutral color appearances. They can be hardwired to operate on any of the voltages listed.
Lights with an aluminum housing resist corrosion better than those with a zinc housing.

Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Housing Material | Equiv. Incand. Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Dia. | Ht. | For Conduit Trade Size | Thread Type | Gender | Environmental Rating | Each | |
| Aluminum | 50W 75W 90W | 120V AC, 208V AC, 240V AC, 277V AC | 1,400 2,800 4,200 | Cool (4,000K) Cool (5,000K) Neutral (3,000K) | 11W 20W 30W | 6 1/8" | 8 1/2" | 1/2 | NPSM | Male | IP66 | 15215K12 | 0000000 |
Outdoor Wall Lights
Light up entryways and paths alongside your building for safe travel after dark. These lights are also known as wall packs. Mount them to outlet boxes on the exterior of your building.
These lights meet UL or ETL for wet locations. Lights rated IP65 are sealed to keep out dust and driving rain.
Styles A-E have a switch for selecting the light appearance. Connect them to your lighting control system or toggle the light sensor to automatically turn them on when it gets dark. Lights with a downcast beam are also known as full cut-off lights. Often installed above doors, they help reduce glare by aiming light down instead of toward your eyes.

Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brightness, lumens | Wattage | Voltage | Sensor Type | Light Appearance | Wd. | Ht. | Dp. | Housing Material | Lens Material | Mounting Hardware Included | Environmental Rating | Specifications Met | Housing Color | Each | |
Built-In LED—Low Profile | |||||||||||||||
| 2,800 4,200 5,600 | 20W 30W 40W | 120-347V AC | Light | Warm (3,000K), Neutral (4,000K), Cool (5,000K) | 9" | 11 1/2" | 4 1/4" | Aluminum | Glass | No | IP65 | UL Listed, C-UL Listed, DLC Listed, UL 1598 | Bronze | 8694N17 | 000000 |

Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brightness, lumens | Wattage | Voltage | Sensor Type | Light Appearance | Wd. | Ht. | Dp. | Housing Material | Lens Material | Mounting Hardware Included | Environmental Rating | Specifications Met | Choose a Housing Color | Each | |
Built-In LED—Downcast Beam, Pivoting Head | |||||||||||||||
| 1,400 2,800 4,200 | 10W 20W 30W | 120-347V AC | Light | Warm (3,000K), Neutral (4,000K), Cool (5,000K) | 7 5/16" | 7 13/16" | 4 15/16" | Aluminum | Polycarbonate Plastic | No | IP65 | UL Listed, C-UL Listed, DLC Listed, UL 1598 | Bronze | 8694N21 | 000000 |
| 4,200 6,300 8,400 | 30W 45W 60W | 120-347V AC | Light | Warm (3,000K), Neutral (4,000K), Cool (5,000K) | 7 5/16" | 7 13/16" | 4 15/16" | Aluminum | Polycarbonate Plastic | No | IP65, IK08 | UL Listed, C-UL Listed, DLC Listed, UL 1598 | 8694N111 | 000000 | |
Single-Pin Base Tubular Light Bulbs
Swap new fluorescent light bulbs into your single-pin base fixture, or upgrade them to LED. Select a light appearance to match your existing lighting. Bulbs with more than one light appearance have a switch, which allows you to match other lights in the room.
LED bulbs last longer and are more efficient than fluorescent bulbs. They work with sockets that are wired directly to the power source. T8 bulbs can be used in T12 sockets that are wired directly to a power source.
Plastic-coated glass bulbs are shatter resistant. If the glass breaks, the coating keeps shards from falling.
Small Pack | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| O'all Lg. | Equiv. Fluorescent Bulb Wattage | Light Appearance | Brightness, lumens | CRI | Bulb Material | Equiv. Fluorescent Bulb Trade Number | Wattage | Rated Life, hrs. | Pkg. Qty. | Pkg. | |
T8 Bulb (1" Dia.) | |||||||||||
LED—Ballast Bypass (Type B) | |||||||||||
| 96" | 60W | Neutral (4,000K) | 4,200 | 80 | Plastic-Coated Glass | F96T8, FO96 | 40W | 50,000 | 10 | 8355K62 | 0000000 |
| 96" | 60W | Cool (5,000K) | 4,200 | 80 | Plastic-Coated Glass | F96T8, FO96 | 40W | 50,000 | 10 | 8355K63 | 000000 |
LED Light Bulbs for High-Intensity Discharge (HID) Lights




Replace high-intensity discharge (HID) lights with the longer-lasting, energy-efficient LEDs. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. LED lights are perceived as brighter at night than high-intensity discharge light technologies, so they require fewer lumens to provide the same brightness. Match your old light’s wattage to find the right LED bulb. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh.
Ballast bypass bulbs eliminate the need for a ballast, so the socket must be wired directly to the power source.
Equiv. Bulb Wattage | Bulb | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Metal Halide | High-Pressure Sodium | Mercury Vapor | Light Appearance | Brightness, lumens | Operating Position | Bulb Dia. | Ht. | Wd. | O'all Lg. | Wattage | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Specifications Met | Each | |
Ballast Bypass | |||||||||||||||
Rectangular Bulb—EX39 Mogul Base | |||||||||||||||
| 100W | 100W | 100W | Warm (3,000K) Neutral (4,000K) Cool (5,000K) | 3,500 4,200 4,300 | Base Down, Horizontal | __ | 6.9" | 3" | 6.9" | 30W | 50,000 | 3.28 | UL Listed, C-UL Listed | 1638N193 | 000000 |
Tubular Bulb—E26 Medium (Standard Household) Base | |||||||||||||||
| 100W | 100W | 100W | Warm (3,000K) Neutral (4,000K) Cool (5,000K) | 3,780 4,200 4,050 | Base Up, Base Down, Horizontal | 2 5/16" | __ | __ | 6 3/4" | 27W | 50,000 | 3.25 | UL Listed, C-UL Listed | 1638N339 | 00000 |
Screw-In Base Light Bulbs
Use these bulbs in standard sockets, panels, and appliances. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. Bulbs with a warm light appearance have yellow tones. Bulbs with a neutral light appearance are commonly used in workspaces. Bulbs with a cool or daylight appearance have white/blue tones and are good for inspecting. A bulb’s estimated yearly energy cost is based on 3 hours of usage per day at $0.11 per kWh.
Halogen bulbs are slightly more energy efficient than incandescent bulbs, but they generate more heat.
| Equiv. Incand. Bulb Wattage | Light Appearance | Brightness, lumens | Light Technology | Light Setting | Bulb Shape No. | Bulb Material | Color | Wattage | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Each | |
Pointed Bulb—Miniature Candelabra Base (7/16" Dia.) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
120V AC/120V DC | ||||||||||||
| 250W | Warm (2,900K) | 4,200 | Halogen | Dimmable | T4 1/2 | Glass | Clear | 250W | 2,000 | 30.20 | 1513K11 | 00000 |