Find the right lumen level to brighten your space. Then, compare the way warm, neutral, and cool lighting affect the appearance of everyday objects.
Washdown Ceiling Lights
IP or NEMA rated, these lights have a sealed lens to keep dust and moisture out for protection against washdowns. All meet ETL or UL standards for wet locations.
Mount these lights to the ceiling with the included brackets. For lights with mounting V-hooks, you can suspend them from the ceiling with chains (not included).
Styles A-B have a wraparound lens that allows light to shine from the sides as well as the bottom. IP66 lights withstand high-pressure washdowns. NEMA 4X lights withstand corrosive liquids and spraying water—including washdowns.
Lights that meet NSF/ANSI 2 standards are commonly used in food handling and processing areas with splashing liquid.

Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Lg. | Wd. | Ht. | Brightness, lumens | Wattage | Voltage | Electrical Connection Type | Light Appearance | Light Setting | Mounting Hardware Included | Includes | Environmental Rating | Specifications Met | Each | |
Made Outside the U.S. | |||||||||||||||
Built-In LED | |||||||||||||||
| B | 47 1/2" | 3 7/8" | 3 3/4" | 2,800 4,200 5,600 | 22W 32W 46W | 120-347V AC | Hardwire | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP66, NEMA 4X | UL Listed, DLC Listed, NSF/ANSI 2 Splash Zone | 1616K345 | 0000000 |
Outdoor Ceiling Lights
Hang these lights in garages and covered walkways to create a safe, well-lit path. They’re also known as canopy lights. All are either UL or ETL Listed for use in wet locations. Select a light appearance to match your existing lighting. If you’re not sure what temperature you need, choose a light with a selectable light appearance. You can adjust the temperature with a switch.
Fasten these lights to a ceiling or to an outlet box.
Styles B and D illuminate both the ceiling and the ground, so your space feels brighter and larger. When replacing older fixtures, use a mounting plate (sold separately) to cover any hole larger than the dimensions of the new fixture.
Lights with a light sensor automatically turn on in low light conditions. When adding a motion sensor to a light that doesn’t already have one, you’ll also need a remote (sold separately). Use the remote to set the motion sensor’s reach and adjust how much darkness triggers the light sensor.
Lights rated IP65 are sealed to keep out dust and driving rain.

Lights | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Motion Sensors | Remotes | 12 1/2" × 12 1/2" Bronze Mounting Plates | 16" × 16" White Mounting Plates | |||||||||||||||||
| Brightness, lumens | Wattage | Voltage | Light Appearance | Dia. | Dp. | Housing Material | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Specifications Met | Housing Color | Each | Each | Each | Each | Each | |||||
Built-In LED with Light Sensor | ||||||||||||||||||||||
| 5,600 6,400 8,000 | 35W 40W 50W | 120-347V AC | Warm (3,000K), Neutral (4,000K), Cool (5,000K) | 11 13/16" | 3 1/2" | Aluminum | No | 8 | 3/16" | IK08, IP65 | UL Listed, C-UL Listed, DLC Listed | White | 8463N22 | 0000000 | 8463N24 | 000000 | 8463N25 | 000000 | 8463N26 | 000000 | 8463N27 | 000000 |
Outdoor Wall Lights
Light up entryways and paths alongside your building for safe travel after dark. These lights are also known as wall packs. Mount them to outlet boxes on the exterior of your building.
These lights meet UL or ETL for wet locations. Lights rated IP65 are sealed to keep out dust and driving rain.
Styles A-E have a switch for selecting the light appearance. Connect them to your lighting control system or toggle the light sensor to automatically turn them on when it gets dark.

Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brightness, lumens | Wattage | Voltage | Sensor Type | Light Appearance | Wd. | Ht. | Dp. | Housing Material | Lens Material | Mounting Hardware Included | Environmental Rating | Specifications Met | Housing Color | Each | |
Built-In LED—Low Profile | |||||||||||||||
| 2,800 4,200 5,600 | 20W 30W 40W | 120-347V AC | Light | Warm (3,000K), Neutral (4,000K), Cool (5,000K) | 9" | 11 1/2" | 4 1/4" | Aluminum | Glass | No | IP65 | UL Listed, C-UL Listed, DLC Listed, UL 1598 | Bronze | 8694N17 | 000000 |
| 5,600 8,400 11,200 | 40W 60W 80W | 120-347V AC | Light | Warm (3,000K), Neutral (4,000K), Cool (5,000K) | 13 13/16" | 8 15/16" | 4 1/2" | Aluminum | Glass | No | IP65 | UL Listed, C-UL Listed, DLC Listed, UL 1598 | Bronze | 8694N18 | 000000 |
LED Light Bulbs for High-Intensity Discharge (HID) Lights


Replace high-intensity discharge (HID) lights with the longer-lasting, energy-efficient LEDs. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. LED lights are perceived as brighter at night than high-intensity discharge light technologies, so they require fewer lumens to provide the same brightness. Match your old light’s wattage to find the right LED bulb. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh.
Ballast bypass bulbs eliminate the need for a ballast, so the socket must be wired directly to the power source.
Equiv. Bulb Wattage | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Metal Halide | High-Pressure Sodium | Mercury Vapor | Light Appearance | Brightness, lumens | Operating Position | Bulb Dia. | O'all Lg. | Wattage | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Specifications Met | Each | |
Ballast Bypass | |||||||||||||
Tubular Bulb—E26 Medium (Standard Household) Base | |||||||||||||
| 150W | 150W | 150W | Warm (3,000K) Neutral (4,000K) Cool (5,000K) | 5,040 5,600 5,400 | Base Up, Base Down, Horizontal | 3 3/8" | 7 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 1638N417 | 000000 |