About Brightness
More
About Light Appearance
More
Step Lights




Illuminate steps to reduce the risk of tripping or falling, especially at night or in poorly lit areas. They mount flush with your wall or step, so they won’t get snagged or bumped. A glass lens protects the LEDs from dust and damage. UL listed for wet locations, these lights are sealed to keep out humidity as well as dripping and splashed liquids.
Mount these lights in a standard 1-gang outlet box (not included) with the included mounting bracket.
Install wall-mount lights alongside the step. Install step-mount lights on the riser of the step.
Housing | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Color | Material | Ht. | Wd. | Dp. | Brightness, lumens | Light Appearance | Wattage | Voltage | Light Setting | Environment | Specifications Met | Each | |
Built-In LED | |||||||||||||
Wall Mount | |||||||||||||
Gray | Aluminum | 5" | 3" | 1 5/8" | 200 | Warm (3,000K) | 3W | 120V AC | Dimmable | Wet Location | UL Listed | 00000000 | 000000 |
Step Mount | |||||||||||||
Gray | Aluminum | 3" | 5" | 1 5/8" | 400 | Warm (3,000K) | 5W | 120V AC | Dimmable | Wet Location | UL Listed | 00000000 | 00000 |
Corrosion-Resistant Washdown Bay Lights


Illuminate harsh, wet areas, even outside in extreme weather—these lights are often used on ship building ports. Rated NEMA 4X and UL marine listed, they’re sealed against heavy rain and washdowns, and they won’t corrode from salt water or cleaning chemicals. They’re also IP rated to stay sealed in dusty conditions. And with a durable glass lens, they’re rated IK08 for impact resistance. They’ll work in temperatures from -40° F to 145° F. Bright enough for environments that require high visibility, these lights have a cool appearance that highlights white and blue tones.
A quick-connect mount lets you wire these lights to an outlet box without having to hold them in place. First, wire the mount to your outlet box with a 3/4" conduit connector. Then twist the light into the mount to lock it in place.
These lights are DLC (DesignLight Consortium) listed, so they’ve been tested to confirm their energy efficiency. They’re also CE Marked to meet European safety standards.
Overall | Housing | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Ht. | For Ceiling Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Material | Color | Mounting Hardware Included | Environmental Rating | Specifications Met | Each | |
Built-In LED | ||||||||||||||
16 9/32" | 12 31/32" | 5 11/32" | 12'-25' | 15,000 | Cool (5,000K) | 111W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 000000000 |
16 9/32" | 12 31/32" | 5 11/32" | 12'-25' | 19,500 | Cool (5,000K) | 154W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
18 11/16" | 15 15/16" | 5 1/2" | 12'-25' | 24,000 | Cool (5,000K) | 180W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
18 11/16" | 15 15/16" | 5 1/2" | 25'-35' | 30,000 | Cool (5,000K) | 231W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
18 11/16" | 15 15/16" | 5 1/2" | 30'-45' | 38,000 | Cool (5,000K) | 317W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
Hazardous Location Bay Lights

Use these lights in large, open areas such as warehouses and manufacturing spaces where the ceiling is up to 30-ft. high. They are ETL and C-ETL listed for Class I Division 2 Groups A, B, C, and D, Class II Divisions 1 and 2, Groups E, F, and G, and Class III Divisions 1 and 2 for use in environments where ignitable concentrations of acetylene, hydrogen, ethylene, and propane occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. With built-in LEDs, these lights last longer, are more efficient, and generate less heat than other light technologies. They produce a neutral light appearance, which creates a balanced environment for general work areas. These lights produce a wide beam of uniform light. Lights can be hardwired to operate on any of the voltages listed. Thread onto 3/4 NPT conduit to suspend lights from the ceiling.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bay Light Type | Lg. | Wd. | Ht. | Equiv. Metal Halide Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Conduit Trade Size | Thread Type | Gender | Mounting Hardware Included | Each | |
Built-In LED Bulbs | ||||||||||||||
High | 12 5/8" | 9 1/2" | 10 3/8" | 400W | 120V AC, 208V AC, 240V AC, 277V AC | 11,200 | Neutral (4,000K) | 80W | 3/4 | NPT | Female | No | 0000000 | 0000000 |
Hazardous Location Ceiling and Wall Lights with Guard








Also known as jelly jar lights. These fixtures have a heat-resistant lens and a guard that protects the lens from breaking. They are CSA certified for hazardous locations where flammable/combustible gases, vapors, and liquids may be present. They are rated NEMA 4X for protection against corrosion and washdowns. Lights are sealed to keep moisture out. They can be hardwired to operate on any of the voltages listed. Some work with LED or incandescent bulbs (sold separately).
Styles 1, 2, 3, 5, and 6 can be used in environments where ignitable concentrations of flammable/combustible gases, vapors, and liquids or combustible dust occur infrequently, such as in the case of an accidental spill or failure of a ventilation system, and where combustible/ignitable fibers or flyings are present under normal operating conditions and/or during frequent equipment maintenance or failure. Rated for Class I, Division 2, Groups A, B, C, and D; Class II, Division 2, Groups F and G; and Class III, Divisions 1 and 2, these lights withstand acetylene, hydrogen, ethylene, propane, carbonaceous dusts, and nonconductive dusts.
O'all | Mounting Holes | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Dia. | Ht. | Dp. | Voltage | Bulbs Included | No. of Bulbs Required | Screw-In Base Size | Wattage | Max. Wattage per Bulb | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
Built-In LED Bulbs | ||||||||||||||||||
Ceiling Thread On | ||||||||||||||||||
1 | 4 1/2" | 8 1/2" | __ | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | __ | __ | CSA Certified, CSA-US Certified | 0000000 | 0000000 |
2 | 4 1/2" | 8 1/8" | __ | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
Wall Thread On | ||||||||||||||||||
3 | 4 1/2" | 9 1/2" | 7 3/8" | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
For Incandescent Bulbs | ||||||||||||||||||
Ceiling Fastener Mount | ||||||||||||||||||
2 | 4 3/4" | 10 7/8" | __ | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 00000000 | 000000 |
Ceiling Thread On | ||||||||||||||||||
5 | 4 1/2" | 11 1/4" | __ | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | __ | __ | CSA Certified, CSA-US Certified | 00000000 | 000000 |
Wall Fastener Mount | ||||||||||||||||||
6 | 4 1/2" | 12 1/4" | 7 1/4" | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 00000000 | 000000 |
High-Temperature Hazardous Location Ceiling Lights

Built for hot, hazardous areas such as steel mills and refineries, these lights work in temperatures up to 212° F. Rated NEC Classes I and II, they’re safe to use where there are ignitable concentrations of flammable or combustible gases, vapors, liquids, and dust. Rated IP67 and NEMA 6, they’re sealed against humidity, washdowns, and even temporary submersion. They’ll also stay sealed in dusty conditions.
Mount these lights with the included bracket. It tilts to direct light where you need it.
These lights last at least a year when used at 212° F continuously. And at 131° F, they’ll last almost 7 years.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Overall | Housing | Mounting Holes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dia. | Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Temp. Range, °F | Material | Color | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Specifications Met | Includes | Each | |
Built-In LED | ||||||||||||||||
9 3/16" | 6 1/2" | 6,000 | Cool (5,000K) | 60W | 120V AC | -40° to 212° | Aluminum | Gray | No | 4 | 5/16" | NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; IP67; NEMA 6 | UL Listed | Adjustable Bracket | 00000000 | 000000000 |
Wet-Location Ceiling and Wall Lights with Guard




Also known as jelly jar lights. These fixtures have a heat-resistant lens and a guard that protects the lens from breaking. Lights are sealed to keep out humidity and dripping, splashing, and falling liquids.
Lights with built-in LEDs last longer, are more efficient, and generate less heat than other light technologies. They emit a neutral white light often found in workspaces.
Lights without bulbs work with medium (standard household) screw-in base LED, CFL, halogen, and incandescent bulbs (sold separately).
Lights with a tempered glass lens are more impact resistant than those with a glass lens.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting Location | Dia. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Outlet Box Dia. | For Conduit Trade Size | Thread Type | Mounting Hardware Included | No. of | Dia. | Each | |
Ceiling (Fastener Mount) | 4 5/8" | 10 5/8" | __ | 150W | 120V AC | 600 | Neutral (4,000K) | 15W | 4 5/8" | 1/2 | NPSM | Yes | 2 | 3/16" | 00000000 | 0000000 |
Wall (Fastener Mount) | 4 1/2" | 11 3/8" | 7 1/2" | 150W | 120V AC | 600 | Neutral (4,000K) | 15W | 4 3/8" | 1/2 | NPSM | Yes | 2 | 3/16" | 00000000 | 000000 |
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting Location | Dia. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Outlet Box Dia. | For Conduit Trade Size | Thread Type | Mounting Hardware Included | No. of | Dia. | Each | |
Wall (Fastener Mount) | 4 1/2" | 10" | 7 1/4" | 150W | 120V AC | No | 1 | 150W | 4 1/4" | 3/4 | NPT | Yes | 2 | 3/8" | 00000000 | 000000 |
Dusk-to-Dawn Pole-Top Lights

Mount these lights on a pole to illuminate pedestrian areas such as streets and walkways. No need for timers—a sensor automatically turns the light on at dusk and off at dawn. With built-in LEDs, these lights last longer, are more efficient, and generate less heat than other technologies. They produce a neutral white light. All include hardware for mounting to poles with 1 5/8" and 2 3/8" OD.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Equiv. Metal Halide Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Dia. | Ht. | Dp. | Arm Lg. | Mounting Hardware Included | Environment | Environmental Rating | Specifications Met | Each | |
Built-In LED Bulbs | ||||||||||||||
250W | 120V AC/277V AC | 5,700, 8,300 | Neutral (4000K, 4500K, 5000K) | 40W, 60W | 9" | 6 1/2" | 29 3/4" | 24" | Yes | Damp, Washdown | IP65 | C-UL Listed, UL Listed | 00000000 | 0000000 |
Adjustable-Head Dusk-to-Dawn Wall Lights

Heads adjust to any angle to direct light where needed. No need for timers—a sensor automatically turns the light on at dusk and off at dawn. These lights work with LED, CFL, halogen, and incandescent bulbs (sold separately).
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Bulbs Included | No. of Bulbs Required | Screw-In Base Size | Max. Wattage per Bulb | Wd. | Ht. | Dp. | Environment | Mounting Hardware Included | Each | |
For LED, CFL, Halogen, and Incandescent Bulbs | |||||||||||
120V AC | No | 2 | Medium (Standard Household) | 150W | 9 7/8" | 2 7/8" | 4 1/2" | Wet Location | Yes | 000000 | 000000 |
Store-Flat Dock Lights


With built-in LEDs, these lights deliver all the brightness of larger dock lights in a low-profile design. A hinge stop keeps the arm from extending past the dock door, and the curved design fits around the track. Swing them out to light the inside of your trailer, then fold them flat against the door when not in use. Rated for damp locations, these lights handle humidity and moisture.
Plug them into a three-prong outlet—no hardwiring required. Turn them on and off with the switch near the hinge. Choose the 36” model if you need to mount these more than a foot from the door opening.
Arm | Mounting Holes | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Reach | Adjustability | Brightness, lumens | Light Appearance | Voltage | Wattage | Material | Color | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
Built-In LED | |||||||||||||
24" | Horizontal | 1,300 | Cool (5,000K) | 120V AC | 13W | Powder-Coated Steel | Gray, Yellow | No | 8 | 7/16" | UL Listed, C-UL Listed | 00000000 | 0000000 |
36" | Horizontal | 1,300 | Cool (5,000K) | 120V AC | 13W | Powder-Coated Steel | Gray, Yellow | No | 8 | 7/16" | UL Listed, C-UL Listed | 00000000 | 000000 |
Wet-Location Emergency Backup Lights

Lights that cannot be sold to California or Oregon are restricted due to energy efficiency requirements.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Batteries Included | Run Time, hrs. | Mounting Hardware Included | Cannot Be Sold To | Each | |
Built-In LED Bulbs | |||||||||||||
8" | 12 1/4" | 3 1/2" | 5W | 120V AC, 277V AC | 100 | Cool (5000K) | 3.75W | Yes | 1.5 | Yes | CA, OR | 0000000 | 0000000 |
Washdown Emergency Backup Lights

Rated NEMA 4X, these lights are protected from corrosion and washdowns. They have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Mount add-on heads in remote areas to extend emergency lighting. Wire up to three of these heads to your emergency backup light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Max. No. of Add-On Heads | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Each | |
Built-In LED Bulbs | ||||||||||||||||
10 7/8" | 12" | 6" | 16W | 120V AC, 277V AC | 600 | Cool (5000K) | 8.2W | 3 | Yes | 1.5 | No | 4 | 5/16" | NEMA 4X, IP66 | 0000000 | 0000000 |
Add-On Heads | 0000000 | Each | 000000 |
Hazardous Location Emergency Backup Lights

These lights are UL listed for Class I, Division 2, Groups A, B, C, and D for use in environments where ignitable concentrations of hazardous material occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They withstand acetylene, hydrogen, ethylene, and propane. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed. They cannot be sold to the listed areas due to energy efficiency requirements.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Voltage | Bulbs Included | Brightness, lumens | Light Appearance | Max. Wattage per Bulb | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Specifications Met | Cannot Be Sold To | Each | |
For LED Bulbs | ||||||||||||||||
10 5/16" | 16 1/2" | 5 1/2" | 120V AC, 277V AC | Yes | 800 | Cool (5000K) | 5W | Yes | 1.5 | No | 4 | 5/16" | UL Listed | CA, OR, VT | 00000000 | 000000000 |