Corrosion-Resistant Washdown Bay Lights


Illuminate harsh, wet areas, even outside in extreme weather—these lights are often used on ship building ports. Rated NEMA 4X and UL marine listed, they’re sealed against heavy rain and washdowns, and they won’t corrode from salt water or cleaning chemicals. They’re also IP rated to stay sealed in dusty conditions. And with a durable glass lens, they’re rated IK08 for impact resistance. They’ll work in temperatures from -40° F to 145° F. Bright enough for environments that require high visibility, these lights have a cool appearance that highlights white and blue tones.
A quick-connect mount lets you wire these lights to an outlet box without having to hold them in place. First, wire the mount to your outlet box with a 3/4" conduit connector. Then twist the light into the mount to lock it in place.
These lights are DLC (DesignLight Consortium) listed, so they’ve been tested to confirm their energy efficiency. They’re also CE Marked to meet European safety standards.
Overall | Housing | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Ht. | For Ceiling Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Material | Color | Mounting Hardware Included | Environmental Rating | Specifications Met | Each | |
Built-In LED | ||||||||||||||
16 9/32" | 12 31/32" | 5 11/32" | 12'-25' | 15,000 | Cool (5,000K) | 111W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 000000000 |
16 9/32" | 12 31/32" | 5 11/32" | 12'-25' | 19,500 | Cool (5,000K) | 154W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
18 11/16" | 15 15/16" | 5 1/2" | 12'-25' | 24,000 | Cool (5,000K) | 180W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
18 11/16" | 15 15/16" | 5 1/2" | 25'-35' | 30,000 | Cool (5,000K) | 231W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
18 11/16" | 15 15/16" | 5 1/2" | 30'-45' | 38,000 | Cool (5,000K) | 317W | 120-277V AC | Aluminum | Gray | Yes | IP66, IP67, NEMA 4X, IK08 | UL Marine Listed, DLC Listed, CE Marked | 00000000 | 00000000 |
Hazardous Location Ceiling Lights


These lights are UL listed or CSA certified for hazardous locations where flammable/combustible gases, vapors, and liquids may be present. They have a sealed lens and can be hardwired to operate on any of the voltages listed.
Styles 1-2 can be used where hazardous material occurs infrequently. They have built-in LEDs that last longer, are more efficient, and generate less heat than other light technologies. Style 1 are housed in durable stainless steel.
Style 3 withstand hazardous material under normal operating conditions. Housed in lightweight aluminum, they have built in LEDs that last longer, are more efficient, and generate less heat than other light technologies.
Lights with a cool appearance highlight white/blue tones that are good for inspecting.
All are IP66 rated for protection from washdowns. NEMA 4X rated lights protect their parts from corrosion.

Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Lg. | Wd. | Ht. | Voltage | Light Appearance | Wattage | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | Environmental Rating | Specifications Met | Each | |
Fastener Mount | ||||||||||||||
1 | 24" | 4 3/4" | 7 1/4" | 120V AC, 208V AC, 240V AC, 277V AC | Cool (4,100K) | 27W | Stainless Steel | 3/4 | NPT | No | NEC Class I Division 2 Groups A, B, C, D; NEC Zone 2 Groups IIC, IIB, IIA; IP66; NEMA 4X; NEC Class II Division 2 Groups F, G | UL Listed, C-UL Listed, UL Marine Listed | 0000000 | 000000000 |

Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Lg. | Wd. | Ht. | Voltage | Light Appearance | Wattage | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | Environmental Rating | Specifications Met | UL File Number | Each | |
Fastener Mount | |||||||||||||||
3 | 53" | 11 1/2" | 6 1/2" | 120V AC, 208V AC, 240V AC, 277V AC | Cool (4,100K) | 46W | Aluminum | 1/2 | NPT | No | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Zone 1 Groups IIB, IIA; NEC Zone 2 Groups IIC, IIB, IIA; IP66; NEMA 4X; NEMA 7; NEMA 9 | UL Listed, C-UL Listed, UL Marine Listed | E46116 | 0000000 | 000000000 |
Hazardous Location Ceiling and Wall Lights with Guard










Also known as jelly jar lights. These fixtures have a heat-resistant lens and a guard that protects the lens from breaking. They are CSA certified for hazardous locations where flammable/combustible gases, vapors, and liquids may be present. They are rated NEMA 4X for protection against corrosion and washdowns. Lights are sealed to keep moisture out. They can be hardwired to operate on any of the voltages listed. Some work with LED or incandescent bulbs (sold separately).
Styles 1, 2, 3, 5, and 6 can be used in environments where ignitable concentrations of flammable/combustible gases, vapors, and liquids or combustible dust occur infrequently, such as in the case of an accidental spill or failure of a ventilation system, and where combustible/ignitable fibers or flyings are present under normal operating conditions and/or during frequent equipment maintenance or failure. Rated for Class I, Division 2, Groups A, B, C, and D; Class II, Division 2, Groups F and G; and Class III, Divisions 1 and 2, these lights withstand acetylene, hydrogen, ethylene, propane, carbonaceous dusts, and nonconductive dusts.
Styles 4 and 7 can be used in environments where ignitable concentrations of hazardous material are present under normal operating conditions, and/or during frequent equipment maintenance or failure. Rated for Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2, these lights withstand ethylene, propane, conductive or metal dusts, carbonaceous dusts, nonconductive dusts, and combustible/ignitable fibers or flyings.
O'all | Mounting Holes | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Dia. | Ht. | Dp. | Voltage | Bulbs Included | No. of Bulbs Required | Screw-In Base Size | Wattage | Max. Wattage per Bulb | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
Built-In LED Bulbs | ||||||||||||||||||
Ceiling Thread On | ||||||||||||||||||
1 | 4 1/2" | 8 1/2" | __ | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | __ | __ | CSA Certified, CSA-US Certified | 0000000 | 0000000 |
2 | 4 1/2" | 8 1/8" | __ | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
Wall Thread On | ||||||||||||||||||
3 | 4 1/2" | 9 1/2" | 7 3/8" | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
For Incandescent Bulbs | ||||||||||||||||||
Ceiling Fastener Mount | ||||||||||||||||||
2 | 4 3/4" | 10 7/8" | __ | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 00000000 | 000000 |
4 | 7 1/2" | 14 3/8" | __ | 120V AC, 208V AC, 240V AC | No | 1 | Medium (Standard Household) | __ | 150W | Aluminum | 3/4 | NPT | No | 4 | 5/16" | CSA Certified, MS16555-650, MS9321-9 | 0000000 | 000000 |
Ceiling Thread On | ||||||||||||||||||
5 | 4 1/2" | 11 1/4" | __ | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | __ | __ | CSA Certified, CSA-US Certified | 00000000 | 000000 |
Wall Fastener Mount | ||||||||||||||||||
6 | 4 1/2" | 12 1/4" | 7 1/4" | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 00000000 | 000000 |
7 | 7 1/2" | 15 7/8" | 14 1/2" | 120V AC, 208V AC, 240V AC | No | 1 | Medium (Standard Household) | __ | 150W | Aluminum | 3/4 | NPT | No | 2 | 1/4" | CSA Certified, MS16555-650, MS9321-9 | 0000000 | 00000000 |
High-Temperature Hazardous Location Ceiling Lights

Built for hot, hazardous areas such as steel mills and refineries, these lights work in temperatures up to 212° F. Rated NEC Classes I and II, they’re safe to use where there are ignitable concentrations of flammable or combustible gases, vapors, liquids, and dust. Rated IP67 and NEMA 6, they’re sealed against humidity, washdowns, and even temporary submersion. They’ll also stay sealed in dusty conditions.
Mount these lights with the included bracket. It tilts to direct light where you need it.
These lights last at least a year when used at 212° F continuously. And at 131° F, they’ll last almost 7 years.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Overall | Housing | Mounting Holes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dia. | Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Temp. Range, °F | Material | Color | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Specifications Met | Includes | Each | |
Built-In LED | ||||||||||||||||
9 3/16" | 6 1/2" | 6,000 | Cool (5,000K) | 60W | 120V AC | -40° to 212° | Aluminum | Gray | No | 4 | 5/16" | NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; IP67; NEMA 6 | UL Listed | Adjustable Bracket | 00000000 | 000000000 |
Hazardous Location Large-Area Floodlights

These lights are UL listed for Class I, Division 2, Groups A, B, C, and D for environments where ignitable concentrations of acetylene, hydrogen, ethylene, and propane occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They can be hardwired to operate on any of the voltages listed. They require a metal halide bulb (sold separately). These floodlights cannot be sold to California due to local energy efficiency regulations.
Lights | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Bulbs | ||||||||||||||
Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Wd. | Ht. | Dp. | For Conduit Trade Size | Thread Type | Gender | Mounting Hardware Included | Cannot Be Sold To | Each | Each | ||
For Blown Tubular BT37 Metal Halide Bulbs | |||||||||||||||
120V AC, 208V AC, 240V AC, 277V AC | No | 1 | 400W | 17 1/4" | 16 1/4" | 7 5/8" | 1/2 | NPT | Female | Yes | CA | 0000000 | 0000000 | 0000000 | 000000 |
Motion-Sensing Security Lights

Heads adjust to any angle to direct light where needed. These lights automatically turn on when the sensor detects motion. Lights turn off when an area is unoccupied.
Lights with built-in LEDs last longer, are more efficient, and generate less heat than other technologies.
Style C are battery-operated—use where you don't have access to electricity. These lights emit a cool light appearance, which highlights white/blue tones creating good visibility at night. They detect motion up to 30 feet away.

Overall | Batteries | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Equiv. Incandescent Bulb Wattage | Brightness, lumens | Wd. | Ht. | Dp. | Environment | Environmental Rating | Max. Sensing Distance, ft. | Included | No. Required | Size | Mounting Hardware Included | Each | |
13W | 200 | 3 1/2" | 6 1/2" | 4 1/2" | Damp, Outdoor | IP06 | 30 | No | 3 | D | Yes | 0000000 | 000000 |
Plug-In Landscape Lights

No need for wiring—these lights plug-in with a three-prong plug. Use these fixtures to illuminate outdoor areas such as building grounds and entrance signs with a narrow beam of directed light. Heads adjust to any angle to direct light where needed. Lights work with LED, CFL, halogen, and incandescent bulbs (sold separately).
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting Location | Mount Type | Housing Material | Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Screw-In Base Size | Dia. | Ht. | Environment | Plug Type | Cord Lg., ft. | Environmental Rating | Each | |
For LED, CFL, Halogen, and Incandescent Bulbs | |||||||||||||||
Ground | Stake | Aluminum | 120V AC | No | 1 | 150W | Medium (Standard Household) | 2 1/8" | 11 5/8" | Wet Location | Three Prong | 6 | NEMA 3R | 0000000 | 000000 |
Explosion-Proof Dock Lights

Safe to use in areas with ignitable concentrations of flammable or combustible gases, vapors, liquids, and dust, these lights are rated NEC Class I, II, and III. Their housing contains fire and sparks, so they won’t ignite what’s in your environment. They’re rated T4A, an NEC hazardous location temperature classification. This means their surface temperature stays below 248° F to prevent them from reacting with nearby flammable substances. These lights swing out from the wall, and their head tilts and swivels to illuminate loading docks and trailers. UL marine listed and NEMA 4X rated, they stand up to salt water and other corrosive liquids, and they’re sealed to withstand washdowns.
Their lens is tempered glass, so it resists scratches and impact during loading and unloading. Since the lens is clear, the lights give focused illumination that is useful for tasks and spot lighting. The LEDs emit a cool light that highlights white and blue tones and has a brighter appearance than neutral light.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Arm | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Reach | Adjustability | Head Dia. | Brightness, lumens | Voltage | Wattage | Head Material | Arm Material | Color | Environmental Rating | Specifications Met | Each | |
Built-In LED | ||||||||||||
26" | Horizontal | 9 13/32" | 3,800 | 120V AC-277V AC | 44W | Powder-Coated Aluminum | Powder-Coated Steel | Yellow | NEC Class I Division 2 Groups A, B; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups F, G; NEC Class III Divisions 1, 2; NEMA 4X | UL Marine Listed, UL 1598 | 00000000 | 000000000 |
Washdown Emergency Backup Lights

Rated NEMA 4X, these lights are protected from corrosion and washdowns. They have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Mount add-on heads in remote areas to extend emergency lighting. Wire up to three of these heads to your emergency backup light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Max. No. of Add-On Heads | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Each | |
Built-In LED Bulbs | ||||||||||||||||
10 7/8" | 12" | 6" | 16W | 120V AC, 277V AC | 600 | Cool (5000K) | 8.2W | 3 | Yes | 1.5 | No | 4 | 5/16" | NEMA 4X, IP66 | 0000000 | 0000000 |
Add-On Heads | 0000000 | Each | 000000 |