Emergency Backup Lights




When the power goes out, these lights turn on. They have adjustable heads that illuminate the path toward exits during outages. Rated UL 924, their battery provides at least 90 minutes of light. A low-voltage disconnect means the battery shuts off just before it’s fully drained, prolonging its overall lifespan. Lights cannot be sold to the listed areas due to energy efficiency regulations.
All have a manual-test switch that lets you verify the battery and heads are working. Lights with automatic battery testing run a self-check once a month. An indicator tells you if they need maintenance.
Style D-G lights are compatible with add-on heads. Run wiring between add-on heads and your backup light to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Lights for use in damp locations withstand humid and moist conditions.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Replacement Batteries | |||||||||||||||||||
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Output Voltage | Max. Wattage for Add-On Heads | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Environment | Specifications Met | Cannot Be Sold To | Each | Each | ||
| D | 600 | 60 | 6V DC | 6W | Manual | 14 1/2" | 6" | 4 1/4" | 120V AC, 277V AC | 3 | No | 2 | 3/16" | 60° to 80° | __ | UL 924, UL Listed, City of Chicago Approved, New York City Approved | __ | 1474K214 | 000000 | 1474K221 | 000000 |
| E | 600 | 60 | 4.8V DC | 4W | Manual, Automatic | 12 3/8" | 10 1/4" | 2 1/4" | 120V AC, 277V AC | 1 1/2 | No | 4 | 3/16" | 32° to 100° | Damp Location | UL 924, UL Listed, City of Chicago Approved, New York City Approved | __ | 1474K28 | 000000 | ______ | 00 |
| F | 800 | 70 | 6V DC | 22W | Manual, Automatic | 13 3/8" | 11 5/8" | 4 3/8" | 120V AC, 277V AC | 5 | No | 2 | 3/16" | 60° to 80° | __ | UL 924, UL Listed, City of Chicago Approved, New York City Approved | CA, Canada | 1474K216 | 000000 | 1474K222 | 00000 |
| F | 800 | 70 | 9.6V DC | 22W | Manual, Automatic | 13 3/8" | 11 5/8" | 4 3/8" | 120V AC, 277V AC | 5 | No | 2 | 3/16" | 0° to 150° | __ | UL 924, City of Chicago Approved, New York City Approved | __ | 1474K51 | 000000 | 1474K52 | 000000 |
| G | 800 | 50 | 6V DC | 90W | Manual, Automatic | 15 1/2" | 17 1/4" | 8" | 120V AC, 277V AC | 9 | No | 2 | 1/4" | 60° to 80° | __ | UL 924, UL Listed, City of Chicago Approved, New York City Approved | CA, Canada | 1474K218 | 000000 | 1474K219 | 000000 |
Plug-In Emergency Backup Lights


No hardwiring required—these backup lights plug into a standard outlet. They kick on when the power goes out to light the path toward exits. Their battery generates at least 90 minutes of power in compliance with UL 924 standards for backup lights. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained. Direct light where it’s needed by angling the adjustable heads.
All have a manual-test switch that lets you verify the battery and heads are working. Style A and B lights are compatible with add-on heads. Run wiring between add-on heads and your backup light to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Replacement Batteries | |||||||||||||||||||
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Plug Type | Cord Lg., ft. | Voltage | Output Voltage | Max. Wattage for Add-On Heads | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Specifications Met | Each | Each | ||
| A | 600 | 50 | Manual | 14 1/2" | 6" | 4 1/4" | Three Prong | 3 | 120V AC | 6V DC | 6W | 3 | No | 2 | 1/8" | 60° to 80° | UL 924, UL Listed, City of Chicago Approved, New York City Approved | 16035K112 | 0000000 | 1474K221 | 000000 |
| B | 800 | 50 | Manual | 13 1/2" | 11 5/8" | 4 3/8" | Three Prong | 3 | 120V AC | 6V DC | 8W | 5 | No | 2 | 3/16" | 60° to 80° | UL 924, City of Chicago Approved, New York City Approved | 16035K111 | 000000 | 8369K522 | 00000 |