About Brightness
More
About Light Appearance
More
Hazardous Location Recessed Lights
Mount these lights in recessed spaces so the lens is flush with the ceiling or wall. NEC Classes I and II, they’re safe to use in paint spray booths, blast booths, and other areas with ignitable concentrations of flammable or combustible gases, vapors, liquids, and dust.
LED lights have a cool light appearance that highlights white and blue tones for high visibility. They are lighter and easier to install than fluorescent lights, and you never have to change a light bulb. They’re UL rated for wet locations, so they’re sealed against humidity and dripping, splashing, and falling liquids.

Overall | Housing | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Material | Color | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Specifications Met | Each | |
51 7/8" | 18" | 2 1/8" | 6,330 | Cool (5,000K) | 62W | 120-277V AC | Steel | White | No | 12 | 5/16" | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G | ETL Listed, C-ETL Listed, UL 1598 | 000000000 | 0000000 |
52 1/2" | 18" | 3 1/2" | 14,050 | Cool (5,000K) | 145W | 120-277V AC | Steel | White | No | 12 | 5/16" | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G | ETL Listed, C-ETL Listed, UL 1598 | 000000000 | 00000000 |
Explosion-Proof Dock Lights

Safe to use in areas with ignitable concentrations of flammable or combustible gases, vapors, liquids, and dust, these lights are rated NEC Class I, II, and III. Their housing contains fire and sparks, so they won’t ignite what’s in your environment. They’re rated T4A, an NEC hazardous location temperature classification. This means their surface temperature stays below 248° F to prevent them from reacting with nearby flammable substances. These lights swing out from the wall, and their head tilts and swivels to illuminate loading docks and trailers. UL marine listed and NEMA 4X rated, they stand up to salt water and other corrosive liquids, and they’re sealed to withstand washdowns.
Their lens is tempered glass, so it resists scratches and impact during loading and unloading. Since the lens is clear, the lights give focused illumination that is useful for tasks and spot lighting. The LEDs emit a cool light that highlights white and blue tones and has a brighter appearance than neutral light.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Arm | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Reach | Adjustability | Head Dia. | Brightness, lumens | Voltage | Wattage | Head Material | Arm Material | Color | Environmental Rating | Specifications Met | Each | |
Built-In LED | ||||||||||||
26" | Horizontal | 9 13/32" | 3,800 | 120V AC-277V AC | 44W | Powder-Coated Aluminum | Powder-Coated Steel | Yellow | NEC Class I Division 2 Groups A, B; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups F, G; NEC Class III Divisions 1, 2; NEMA 4X | UL Marine Listed, UL 1598 | 00000000 | 000000000 |
Add-On Heads for Emergency Backup Lights

Mount add-on heads in remote areas to extend emergency lighting. Hardwire each head to an emergency backup light; they operate on any of the voltages listed. These add-on heads have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Rated for use in damp locations, these heads withstand exposure to humidity and moisture. Heads adjust to any angle to direct light where needed.
Overall | Head | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Base Dia. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Material | Color | Mounting Hardware Included | Each | |
Built-In LED Bulbs | ||||||||||||
4 5/8" | 7 1/4" | 4 1/2" | 5W | 4.8-12V DC | 45 | Cool (5000K) | 1.25W | Aluminum | White | No | 0000000 | 000000 |
Plug-In Emergency Backup Lights

No need for wiring—these lights plug-in with a two-prong plug. When the power goes out, these lights go on. They have a low-voltage disconnect so they won’t drain the backup battery. The built-in LEDs last longer, are more efficient, and generate less heat than other types of lights.
Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Voltage | Bulbs Included | Brightness, lumens | Light Appearance | Wattage | Plug Type | Cord Lg., ft. | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Each | |
For LED Bulbs | ||||||||||||||||
12 1/8" | 5 1/2" | 3 7/8" | 120V AC | Built-In LED | 1,100 | Daylight (6000K) | 10.8W | Two Prong | 3 | Yes | 1.5 | Yes | 4 | 3/16" | 00000000 | 0000000 |
Emergency Backup Lights


When the power goes out, these lights go on. These backup lights have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Rated for use in damp locations, these lights withstand exposure to humidity and moisture. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Lights with a plastic housing resist corrosion better than lights with a steel housing.
Lights with a steel housing are more durable than lights with a plastic housing. Mount add-on heads in remote areas to extend emergency lighting. Wire up to three of these heads to your emergency backup light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing Material | Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Max. No. of Add-On Heads | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Each | |
Built-In LED Bulbs | ||||||||||||||||
Plastic | 9 3/4" | 4 3/4" | 3 1/8" | 10W | 120V AC, 277V AC | 220 | Cool (5000K) | 2.4W | __ | Yes | 1.5 | No | 4 | 3/16" | 0000000 | 000000 |
Steel | 12 3/8" | 10 1/4" | 2 1/4" | 15W | 120V AC, 277V AC | 600 | Cool (5000K) | 4W | 3 | Yes | 1.5 | No | 4 | 3/16" | 0000000 | 000000 |
Add-On Heads for Steel Housing Lights | 0000000 | Each | 000000 |
Wet-Location Emergency Backup Lights


Lights that cannot be sold to California or Oregon are restricted due to energy efficiency requirements.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Batteries Included | Run Time, hrs. | Mounting Hardware Included | Cannot Be Sold To | Each | |
Built-In LED Bulbs | |||||||||||||
7 7/8" | 8" | 2 1/4" | 12W | 120V AC, 277V AC | 300 | Cool (5000K) | 4.1W | Yes | 1.5 | Yes | __ | 0000000 | 0000000 |
8" | 12 1/4" | 3 1/2" | 5W | 120V AC, 277V AC | 100 | Cool (5000K) | 3.75W | Yes | 1.5 | Yes | CA, OR | 0000000 | 000000 |
Washdown Emergency Backup Lights

Rated NEMA 4X, these lights are protected from corrosion and washdowns. They have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Mount add-on heads in remote areas to extend emergency lighting. Wire up to three of these heads to your emergency backup light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Max. No. of Add-On Heads | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Environmental Rating | Each | |
Built-In LED Bulbs | ||||||||||||||||
10 7/8" | 12" | 6" | 16W | 120V AC, 277V AC | 600 | Cool (5000K) | 8.2W | 3 | Yes | 1.5 | No | 4 | 5/16" | NEMA 4X, IP66 | 0000000 | 0000000 |
Add-On Heads | 0000000 | Each | 000000 |