    9 Products
    About Brightness and Light Appearance
    industrial info icon

    Find the right lumen level to brighten your space. Then, compare the way warm, neutral, and cool lighting affect the appearance of everyday objects.

    Emergency Backup Lights

    Image of Product. Front orientation. Emergency Backup Lights. Emergency Backup Lights, Style B.

    Style B

    When the power goes out, these lights turn on. They have adjustable heads that illuminate the path toward exits during outages. Rated UL 924, their battery provides at least 90 minutes of light. A low-voltage disconnect means the battery shuts off just before it’s fully drained, prolonging its overall lifespan.
    All have a manual-test switch that lets you verify the battery and heads are working.
    Style B
    Image of Product. Front orientation. Emergency Backup Lights. Emergency Backup Lights, Style B.
    Wet Environments—Lights for use in wet environments withstand humid and moist conditions.
    Maximum Distance Between Lights—Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
    Overall
    Included
    Mounting
    Holes
    Brightness,
    lm
    Max. Distance
    Between Lights, ft.
    Battery
    Test Type
    Wd.
    Ht.
    Dp.
    Voltage, V AC
    Batteries
    Mounting
    Hardware
    No.
    of
    Dia.
    Temp.,
    ° F
    Environment
    Certification
    Specs.
    Met
    Each
    1 1/2 hr. Backup Battery Life
    22035Manual9 3/4"4 3/4"3 1/8"120, 277YesNo43/16"50 to 100WetUL Listed
    UL 9241474K25000000
     

    Backup Power Supplies for Facility Lights

    Backup Power Supplies
    Image of Product. Back orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Backup Power Supplies.
    Turn your facility lights into emergency lights—no need for generators or separate backup lights. Also known as battery inverters, these power supplies detect outages and shift your lights to battery power. To comply with UL 924 and help you meet NFPA standards, they activate your lights at full brightness for at least 90 minutes, even if they’re off or dimmed. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained.
    An LED indicator tells you whether your lights are using primary or backup power. The indicator also tells you when these power supplies require maintenance. They have a manual test switch, so you can test them without disrupting the power.
    If you have more than one circuit, you’ll need to add a relay to bypass dimmers and on/off controls across circuits. You can also wire these relays to your fire alarm. Pull the alarm to activate lights to full brightness during emergencies, even without an outage. Also known as automatic load control relays.
    Maximum Recommended Power—Maximum recommended power is the total wattage of connected devices that these power supplies can support.
    Cannot Be Sold To—Power supplies that cannot be sold to the listed areas are restricted due to local energy efficiency requirements.
    Overall
    Mounting
    Holes
    Housing
    Wattage,
    W
    Max. Recommended
    Power, W
    Input Voltage,
    V AC
    Output Voltage,
    V AC
    Lg.
    Ht.
    Wd.
    Battery
    Test Type
    Run Time,
    hr.
    Trip Time,
    sec.
    For Conduit
    Trade Size
    Mounting Hardware
    Included
    No.
    of
    Dia.
    Material
    Color
    Temp.,
    ° F
    Features
    Specifications Met
    Cannot Be Sold To
    Each
    3535120 to 277120, 27719 7/8"2 3/4"2 7/8"Manual1.55No45/32"SteelGray32 to 120Remote Test Switch and LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N260000000
    5050120 to 277120, 27722 1/2"2 3/4"3"Manual1.55No45/32"SteelGray32 to 120Remote Test Switch and LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N21000000
    125125120 to 277120, 27723 1/8"11 3/4"4 1/2"Manual1.50.051/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCanada8197N125000000
    125125120 to 277120, 27723 1/8"11 3/4"4 1/2"Manual1.50.051/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL ListedCalifornia8197N122000000
    250250120 to 277120, 27719 1/8"11 5/8"7 5/8"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N12600000000
    375337120 to 277120, 27723"17 3/4"8 1/4"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCalifornia, Canada8197N12300000000
    550495120 to 277120, 27723"17 3/4"8 1/4"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCalifornia, Canada8197N12400000000
    550550120 to 277120, 27719 3/4"22"11"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCanada8197N12700000000