About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Premium Wall-Mount Fans


With a ball-bearing motor and cupped fan blades, these fans last longer and focus airflow better than economy fans. All have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
UL 507 rated fans are rated for outdoor use.
For technical drawings and 3-D models, click on a part number.
Fans | Pole Mounting Brackets | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Cord Lg., ft. | Blade Material | Guard Material | Mount. Fasteners Included | Mount. Hole Dia. | Includes | Specifications Met | Each | Each | ||
120V AC, Single Phase—Three Prong Plug | |||||||||||||||||
Non-Oscillating | |||||||||||||||||
14" | 1,000 | Not Rated | 1,450 | 3 | 1/30 | 1.2 | 8 | Aluminum | Powder-Coated Steel | Yes | 3/8" | Adjustable Mounting Bracket | UL 507 | 0000000 | 0000000 | 00000000 | 000000 |
Rack-Mount Fans

Mount these fans directly to a rack. They have a pivoting extension arm and tilting fan head, so you can direct air where it’s needed and move them out of the way when not in use.
For technical drawings and 3-D models, click on a part number.
Blade Dia. | Arm Reach | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Voltage (Current) | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
120V AC/240V AC, Single Phase—Three Prong Plug | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Non-Oscillating, Tilting | |||||||||||||||
14" | 15" | 2,600 | 66 dBA @ 15 ft. | 1,725 | 1 | 1/4 | 120V AC (2.8 A) 240V AC (1.4 A) | 12 | Powder-Coated Polypropylene Plastic | Galvanized Aluminum | Powder-Coated Steel | Yes | 9/16" | 0000000 | 0000000 |
Wall-Mount Jet-Stream Fans

Often used to cool warehouse aisles and production lines, these fans generate a stream of air that travels farther than air from conventional fans. They have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Mounting Fasteners Included | Each | |
120V AC, Single Phase—Three-Prong Plug | ||||||||||||||||
Non-Oscillating | ||||||||||||||||
14" | 2,600 | 63 dBA @ 15 ft. | 1,725 | 1 | 1/4 | 2.8 | 21" | 20" | 15" | 12 | Polypropylene Plastic | Aluminum | Steel | Yes | 0000000 | 0000000 |
208-230/460V AC, Three Phase—Hardwire | ||||||||||||||||
Non-Oscillating | ||||||||||||||||
14" | 2,600 | 63 dBA @ 15 ft. | 1,725 | 1 | 1/4 | 1.5/0.8 | 21" | 20" | 15" | __ | Polypropylene Plastic | Aluminum | Steel | Yes | 0000000 | 00000000 |
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 14" | 1,800 | Not Rated | 1,525 | 1 | 1/4 | 19" | 19" | 4 1/8" | 18 | 77° F | Steel | Steel | UL Recognized Component | 000000 | 0000000 |
Direct-Drive Wall-Mount Exhaust Fans
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations. Use a collar (sold separately) to connect these fans to a louver.
For technical drawings and 3-D models, click on a part number.
Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Ambient Temperature | Control Type | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||||
14" | 1,520 | 1,660 | 3 | 1/8 | 14 1/2" | 14 1/2" | 17" | 17" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 5/16" | UL Recognized Component | 00000000 | 0000000 |
120V AC, Single Phase—Three-Prong Plug | ||||||||||||||||||
14" | 1,520 | 1,660 | 3 | 1/8 | 14 1/2" | 14 1/2" | 17" | 17" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 5/16" | UL Recognized Component | 00000000 | 000000 |
Exhaust-Side Guards for Wall-Mount Exhaust Fans

Protect the exhaust side of your wall-mount exhaust fans from debris.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||
---|---|---|---|---|---|---|---|
For Blade Dia. | Ht. | Wd. | Dp. | Material | Mounting Fasteners Included | Each | |
14", 16" | 19 3/4" | 19 3/4" | 6" | Galvanized Steel | Yes | 00000000 | 0000000 |
Supply-Side Guards for Wall-Mount Exhaust Fans

Protect the supply side of your wall-mount exhaust fans from debris.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||
---|---|---|---|---|---|---|---|
For Blade Dia. | Ht. | Wd. | Dp. | Material | Mounting Fasteners Included | Each | |
14", 16" | 22 1/4" | 22 1/4" | 16" | Galvanized Steel | Yes | 00000000 | 0000000 |
Direct-Drive Downdraft Roof-Mount Exhaust Fans


Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
Fans with a brushless motor are more efficient than fans with a standard motor. They operate at a wide range of speeds for precise speed control and greater energy savings. They’re also quieter and have a longer lifespan because of their advanced electronic controls.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | |||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Specifications Met | Each | Each | |||
Totally Enclosed Motor Enclosure | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 14" | 520 cfm @ 1/2 in. of H₂O 1,100 cfm @ 0 in. of H₂O | Not Rated | 1,100 | 1/6 | 27 5/16" | 14 5/8" | 21" | 39 | Not Rated | Aluminum | AMCA Certified, ETL Listed | 0000000 | 0000000 | 0000000 | 0000000 |
Totally Enclosed Motor Enclosure—Brushless Motor | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
2 | 14" | 1,900 cfm @ 1/2 in. of H₂O 2,300 cfm @ 0 in. of H₂O | 68 dBA @ 5 ft. | 1,525 | 1/2 | 29 3/4" | 21 3/4" | 21" | 61 | 120° | Aluminum | AMCA Certified, ETL Listed | 0000000 | 00000000 | 0000000 | 000000 |
Open Dripproof Motor Enclosure | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
2 | 14" | 1,800 cfm @ 1/2 in. of H₂O 2,100 cfm @ 0 in. of H₂O | 66 dBA @ 5 ft. | 1,625 | 1/2 | 29 3/4" | 21 3/4" | 21" | 56 | Not Rated | Aluminum | AMCA Certified, ETL Listed | 0000000 | 000000 | 0000000 | 000000 |
Direct-Drive Exhaust Fans

With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
For technical drawings and 3-D models, click on a part number.
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Overall Ht. | Base Wd. | Max. Ambient Temp., °F | Housing Material | Blade Material | Features | Specifications Met | Each | |
Totally Enclosed Motor Enclosure | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
120V AC, Single Phase—Hardwire | ||||||||||||||
14" | 2,100 cfm @ 1/2 in. of H₂O 2,500 cfm @ 0 in. of H₂O | 66 dB @ 5 ft. | 1,650 | Variable | 1 | 55 3/8" | 31" | 350° | Steel | Aluminum | Grease Pan | UL 705, UL 762, ULC-S645, ETL Listed | 0000000 | 000000000 |
Fan Blades




Replace worn and damaged fan blades. Use the included set screw or shaft collar to fasten a blade to your fan's shaft. Fan blades with a keyway are for use on motors with a keyed shaft. For difficult-to-remove hubs and fan blades, use fan blade pullers (not included).
Styles A-C blades are for use in low-airflow applications.
For technical drawings and 3-D models, click on a part number.
Blade | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Style | Dia. | Number of | Pitch | Rotation | For Maximum Motor Speed, rpm | Airflow @ Max. Motor Speed, cfm | Power @ Max. Motor Speed, hp | Hub Material | Includes | Each | |
Aluminum | |||||||||||
For Round Shaft with 5/16" Diameter | |||||||||||
B | 14" | 4 | 23° | Clockwise | 1,800 | 1,860 | 0.14 | Steel | Shaft Collar | 00000000 | 000000 |
B | 14" | 5 | 27° | Clockwise | 1,800 | 2,100 | 0.22 | Steel | Shaft Collar | 00000000 | 00000 |
C | 14" | 3 | 23° | Clockwise | 1,800 | 1,650 | 0.12 | Steel | Shaft Collar | 00000000 | 00000 |
For Round Shaft with 1/2" Diameter | |||||||||||
A | 14" | 5 | 32° | Clockwise | 1,725 | 1,900 | 0.27 | Aluminum | Set Screw | 00000000 | 00000 |
B | 14" | 4 | 23° | Clockwise | 1,800 | 1,860 | 0.14 | Steel | Shaft Collar | 00000000 | 00000 |
B | 14" | 5 | 27° | Clockwise | 1,800 | 2,100 | 0.22 | Steel | Shaft Collar | 00000000 | 00000 |
C | 14" | 3 | 23° | Clockwise | 1,800 | 1,650 | 0.12 | Steel | Shaft Collar | 00000000 | 00000 |
For Keyed Shaft with 5/8" Diameter | |||||||||||
B | 14" | 4 | 23° | Clockwise | 1,800 | 1,860 | 0.14 | Steel | Shaft Collar | 00000000 | 00000 |
B | 14" | 5 | 27° | Clockwise | 1,800 | 2,100 | 0.22 | Steel | Shaft Collar | 00000000 | 00000 |
C | 14" | 3 | 23° | Clockwise | 1,800 | 1,650 | 0.12 | Steel | Shaft Collar | 00000000 | 00000 |
High-Output Fan Blades


Generate at least 25% greater airflow than standard fan blades. Use these blades to replace worn and damaged fan blades. The fan blades with a keyway are for use on motors with a keyed shaft. For difficult-to-remove hubs and fan blades, use fan blade pullers (not included).
Style B 12"-24" dia. blades use the included set screw to fasten a blade to your fan's shaft. The 30" and 36" dia. blades require an SH style quick-disconnect bushing (not included).
For technical drawings and 3-D models, click on a part number.
For Shaft | Blade | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Dia. | Shape | Dia. | Number of | Pitch | Rotation | For Maximum Motor Speed, rpm | Airflow @ Max. Motor Speed, cfm | Power @ Max. Motor Speed, hp | Hub Material | Includes | Each | |
Plastic | |||||||||||||
B | 5/8" | Keyed | 14" | 6 | 35° | Counterclockwise | 5,000 | 6,300 | 4.6 | Aluminum | Set Screw | 0000000 | 000000 |