    35 Products

    Desk Fans

    The head on these fans tilts to direct air where it's needed.
    Electric (120V AC, Single Phase—Three Blade Plug)
    Image of Product. Oscillating. Front orientation. Oscillating Fan. Desk Fans, Electric.

    Oscillating

    Blade
    Overall
    Dia.
    Material
    Airflow,
    ft³/min
    No. of
    Speeds
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Guard
    Material
    Certification
    Each
    Oscillating Fan
    16"Plastic1,70030.724 1/2"18"10 3/4"6SteelETL Listed
    1908K52000000
     

    Wall-Mount Office Fans

    Image of Product. Front orientation. Fans. Wall-Mount Office Fans.
    Keep cool with these personal-size wall-mount fans. The fan head tilts to direct air where it's needed.
    Blade
    Overall
    Dia.
    Material
    Airflow
    No. of
    Speeds
    Current
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Guard
    Material
    Mounting Fasteners
    Included
    Certification
    Includes
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Oscillating Fan, Tilting Fan
    16"Plastic1,700 ft³/min30.7 amp22"18"14"6SteelYesETL Listed
    Mounting Bracket1908K54000000
     

    Machine-Cooling Fans

    Cool large machinery such as transformers. Fans have a totally enclosed motor enclosure for use in dirty, dusty, and wet environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. Fans. Machine-Cooling Fans.
    Blade
    Overall
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Dia.
    Dp.
    Guard Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    16"Aluminum4,500 ft³/min68 dBA @ 6 ft.1,75011/23.1 amp20 1/2"12 1/4"Galvanized SteelNo1/2"1929K120000000
     
    Installation Kits

    Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 3

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 3.

    Style 3

    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Certification
    Each
    316"2,100Not RatedDirect1,66031/819"19"12"21100SteelAluminum
    UL Recognized Component
    1915K820000000

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    16"3,40069 dBA @ 5 ft.Direct1,55013/420 1/8"20 1/8"11 1/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    1932K3400000005353K240000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    16"2,80061 dBA @ 15 ft.Direct1,72511/320 1/8"20 1/8"15"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    2208K420000000005353K240000000

    Direct-Drive Upblast Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 2.

    Style 1

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    116"2,450 ft³/min @ 1/2 in. H₂O
    2,900 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.1,6253/431 7/8"30 1/2"24 3/4"80300Aluminum
    AMCA Certified, ETL Listed
    2232K240000000002230K340000000
     
    Totally Enclosed Motor Enclosure
     
    460V AC, Three Phase—Hardwire
    216"3,050 ft³/min @ 0 in. H₂O70 dBA @ 5 ft.1,7501/322"26 3/4"26"51120Steel2081K26000000002230K125000000
     

    Direct-Drive Downdraft Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 1.

    Style 1

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Brushless Motor—Fans with a brushless motor are more efficient than fans with a standard motor. They operate at a wide range of speeds for precise speed control and greater energy savings. They’re also quieter and have a longer lifespan because of their advanced electronic controls.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    116"2,600 ft³/min @ 1/2 in. H₂O
    3,100 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.1,4503/433 1/4"23 3/8"24"77120Aluminum
    AMCA Certified, ETL Listed
    2011K2200000002230K340000000
     
    Totally Enclosed Motor Enclosure—Brushless Motor
     
    120V AC, Single Phase—Hardwire
    116"2,850 ft³/min @ 1/2 in. H₂O
    3,300 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,525133 1/4"23 3/8"24"74120Aluminum
    AMCA Certified, ETL Listed
    2050K35000000002230K34000000
     

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    16"2,50061 dBA @ 5 ft.Direct1,30011/221 1/4"21 1/4"23 1/2"23 1/2"25 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    19105K24000000000
    Replacement Fan Motors

    Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Rust won't be a problem with the durable plastic housing and louvers on these fans. The fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Each
    16"2,400Not RatedDirect1,72511/321 1/2"23"24 5/8"24 1/8"23"104FiberglassPolypropylene
    6658T820000000

    Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K220000000
    120V AC, Single Phase—3-Blade Plug
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    19455K450000000

    Fan Blades

    Image of Product. Front orientation. Fan Blades. Fan Blades, Style B.
    Image of Product. Front orientation. Fan Blades. Fan Blades, Style C.
    Image of Specification. Keyway. Front orientation. ZoomedIn view. Contains Border. For Keyed Shafts.

    Style B

    Style C

    Keyway

    Replace worn and damaged fan blades. Use the included set screw or shaft collar to fasten a blade to your fan's shaft. Fan blades with a keyway are for use on motors with a keyed shaft. For difficult-to-remove hubs and fan blades, use fan blade pullers (not included).
    Styles B and C—Styles A-C blades are for use in low-airflow applications.
    Blade
    Style
    Dia.
    No.
    of
    Pitch
    Direction
    For Max. Motor
    Speed, rpm
    Airflow @ Max. Motor
    Speed, ft³/min
    Power @ Max.
    Motor Speed, hp
    Hub
    Material
    Includes
    Each
    Aluminum Blade
     
    For Round Shaft with 5/16" Dia.
    B16"423°Clockwise1,8002,6900.27SteelShaft Collar2090K332000000
    C16"323°Clockwise1,8002,0000.16SteelShaft Collar2090K14200000
     
    For Round Shaft with 1/2" Dia.
    B16"423°Clockwise1,8002,6900.27SteelShaft Collar2090K33400000
    B16"527°Clockwise1,8003,3300.51SteelShaft Collar2090K424000000
    C16"323°Clockwise1,8002,0000.16SteelShaft Collar2090K14400000
     
    For Keyed Shaft with 5/8" Dia.
    B16"423°Clockwise1,8002,6900.27SteelShaft Collar2090K33500000
    B16"527°Clockwise1,8003,3300.51SteelShaft Collar2090K425000000
    C16"323°Clockwise1,8002,0000.16SteelShaft Collar2090K14500000
     

    Belt-Drive Downdraft Roof-Mount Exhaust Fans

    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC/208 to 230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    16"2,800 ft³/min @ 1/2 in. H₂O
    3,200 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.Belt1,14513/433 11/16"29 1/4"26"Aluminum
    Aluminum
    Bird Screen2207K310000000002230K340000000

    Exhaust-Side Exhaust Fan Guards for Wall-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fan Guards. Exhaust-Side Exhaust Fan Guards for Wall-Mount Exhaust Fans.
    Protect the exhaust side of your wall-mount exhaust fans from debris.
    Overall
    For Blade
    Dia.
    Ht.
    Wd.
    Dp.
    Material
    Mounting Fasteners
    Included
    Each
    14", 16"19 3/4"19 3/4"6"Galvanized SteelYes19555K520000000

    Direct-Drive Exhaust Fans

    With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
    208V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    16"3,000 ft³/min @ 1/2 in. H₂O
    3,500 ft³/min @ 0 in. H₂O
    71 dB @ 5 ft.Direct1,650Variable1 1/259 3/4"32 5/8"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N13000000000

    Exterior-Wall-Mount Exhaust Fans

    Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
    Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with an open dripproof (ODP) motor enclosure should be used in clean, dry, and indoor locations. You can use these fans with or without duct. To use them with duct, you'll need an angle ring (not included).
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Grilles—Grilles (sold separately) have fixed blades.
    Louvers—Louvers are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
    Exhaust Fans
    Grilles
    Louvers
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    Each
    16"2,400 ft³/min @ 1/4 in. H₂O
    2,800 ft³/min @ 0 in. H₂O
    56 dBA @ 15 ft.Direct1,07511/314"16"16"34 11/16"30 7/8"180Aluminum
    NoC-UL Listed, UL Listed
    1925K50000000001925K8500000001925K94000000

    High-Output Fan Blades

    Image of Product. Front orientation. Fan Blades. High-Output Fan Blades , Style B.
    Image of Specification. Keyway. Front orientation. ZoomedIn view. Contains Border. For Keyed Shafts.

    Style B

    Keyway

    Generate at least 25% greater airflow than standard fan blades. Use these blades to replace worn and damaged fan blades. The fan blades with a keyway are for use on motors with a keyed shaft. For difficult-to-remove hubs and fan blades, use fan blade pullers (not included).
    Style B—Style B 12"-24" dia. blades use the included set screw to fasten a blade to your fan's shaft. The 30" and 36" dia. blades require an SH style quick-disconnect bushing (not included).
    Blade
    Style
    Dia.
    No.
    of
    Pitch
    Direction
    For Max. Motor
    Speed, rpm
    Airflow @ Max. Motor
    Speed, ft³/min
    Power @ Max.
    Motor Speed, hp
    Hub
    Material
    Includes
    Each
    Plastic Blade
     
    For Keyed Shaft with 5/8" Dia.
    B16"635°Counterclockwise4,5008,4005.28Aluminum
    Set Screw5352K34000000
     

    Supply-Side Exhaust Fan Guards for Wall-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fan Guards. Supply-Side Exhaust Fan Guards for Wall-Mount Exhaust Fans.
    Protect the supply side of your wall-mount exhaust fans from debris.
    Overall
    For Blade
    Dia.
    Ht.
    Wd.
    Dp.
    Material
    Mounting Fasteners
    Included
    Each
    14", 16"22 1/4"22 1/4"16"Galvanized SteelYes19555K120000000
    back to top