McMaster-Carr logo
    Filter by
    System of Measurement
    Blade Diameter
    Mounting Location
    Power Source
    Number of Speeds
    Electrical Phase
    Drive Type
    Current
    Industrial Info Snippet
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Guard Material
    Number of Blades
    Electrical Connection
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    32 Products

    Economy Wall-Mount Fans

    Position these wall-mount fans to direct air where it’s needed. All of these fans have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Economy Wall-Mount Fans.
    Fans
    Replacement
    Fan Motors
    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    Fasteners
    Included
    Hole
    Dia.
    Certification
    Includes
    Each
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Steel5,100 ft³/min62 dBA @ 15 ft.1,05031/42.4 amp10DirectPowder-Coated SteelNo3/8"ETL Listed
    Mounting Bracket0000000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated SteelNo3/8"ETL Listed
    Mounting Bracket00000000000000000000000000
     
    Oscillating Fan
    24"Steel5,100 ft³/min62 dBA @ 15 ft.1,05031/42.4 amp10DirectPowder-Coated SteelNo3/8"ETL Listed
    Mounting Bracket00000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated SteelNo3/8"ETL Listed
    Mounting Bracket00000000000000000000000000
     

    Economy Pedestal Fans

    Place these pedestal fans to circulate air where it’s needed. A direct-drive motor means they have fewer moving parts than fans with belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Contains Annotated. Fans. Economy Pedestal Fans.
    Fans
    Replacement
    Fan Motors
    Blade
    Pedestal
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.,
    ft.
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    Material
    Color
    Certification
    Each
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Steel5,100 ft³/min62 dBA @ 15 ft.1,05031/42.4 amp4 to 710DirectPowder-Coated SteelPowder-Coated SteelBlackETL Listed
    0000000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp5 to 710DirectPowder-Coated SteelPowder-Coated SteelBlackETL Listed
    00000000000000000000000000
     
    Oscillating Fan
    24"Steel5,100 ft³/min62 dBA @ 15 ft.1,05031/42.4 amp5 to 710DirectPowder-Coated SteelPowder-Coated SteelBlackETL Listed
    00000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp5 to 710DirectPowder-Coated SteelPowder-Coated SteelBlackETL Listed
    00000000000000000000000000
     

    Economy Beam-Mount Fans

    Image of ProductInUse. Front orientation. Fans. Economy Beam-Mount Fans.
    Attach these fans to beams to direct air where it’s needed. They have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
    Fans with Totally Enclosed Motor Enclosure
    Fans
    Replacement
    Fan Motors
    Blade
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    For Beam
    Wd.
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Steel5,100 ft³/min62 dBA @ 15 ft.1,05031/42.4 amp10DirectPowder-Coated Steel4" to 14"YesETL Listed
    0000000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated Steel4" to 14"YesETL Listed
    00000000000000000000000000
     
    Oscillating Fan
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated Steel4" to 14"YesETL Listed
    00000000000000000000000000
     

    Hanging Box Fans

    Image of ProductInUse. Front orientation. Fans. Hanging Box Fans.
    Easily hang these fans from your ceiling using the attached bracket and a mounting chain kit (sold separately). They're more powerful than our standard box fans. Made with a heavy duty 12-gauge welded wire mesh guard, these fans will stand up to tough environments. Plastic guard clips help reduce vibration between the housing and the guard, making these fans quieter. They require little maintenance thanks to their totally enclosed, high-efficiency motor and sealed ball bearings.
    Fans with Totally Enclosed Motor Enclosure
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Blade
    Overall
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Drive
    Type
    Housing
    Material
    Guard Material
    Bearing
    Type
    Fasteners
    Included
    Hole
    Dia.
    Includes
    Each
    120/240V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    24"Aluminum5,100 ft³/minNot Rated1,65011/24.8 amp
    2.4 amp
    30 1/2"30 1/2"16 1/4"DirectGalvanized SteelGalvanized SteelBall
    No3/8"Plastic Guard Clips00000000000000
     
    Mounting Chain Kits

    Economy Ceiling-Mount Fans

    Hanging from the ceiling, these fans direct air where it's needed. A direct-drive motor means these fans have fewer moving parts than fans with belt-drive motors for less maintenance. A totally enclosed motor enclosure means these fans can be used in dirty and dusty environments. Threaded extension pipe for mounting is not included.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Shown With Extension Pipe (Not Included). Front orientation. Fans. Economy Ceiling-Mount Fans.

    Shown With Extension Pipe

    (Not Included)

    Cannot Be Sold to California—These fans cannot be sold to California due to local energy efficiency requirements.
    Fans
    Replacement
    Fan Motors
    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    Fasteners
    Included
    Hole
    Dia.
    Req. Pipe
    Size
    Certification
    Cannot Be
    Sold To
    Includes
    Each
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated SteelNo3/8"1 1/2
    ETL Listed
    CaliforniaMounting Bracket0000000000000000000000000000
     

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. 120V AC. Direct-Drive Wall-Mount Exhaust Fans .
    Louvers—Fans with louvers create a weather-tight seal when they're turned off. The louvers open automatically on startup and spring closed when not in use.
    Hoods—Hoods (sold separately) help extend the life of your exhaust fan by protecting it from harsh weather, such as severe wind, and debris.
    Exhaust Fans
    Hoods
    For
    Opening
    Overall
    Mounting
    Hole
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Dia.
    Location
    No.
    of
    Includes
    Each
    Each
    24"4,800Not RatedDirect1,72511/225 1/4"25 1/4"28 1/4"28 1/4"20 3/4"100Galvanized SteelAluminum
    3/16"Frame4Louvers00000000000000000000000000000

    Mobile Evaporative Air Coolers

    Image of Product. Front orientation. Evaporative Air Coolers. Mobile Evaporative Air Coolers.
    Image of Specification. Front orientation. NEMA 5-15. Mobile Evaporative Air Coolers.

    NEMA

    5-15

    Also known as swamp coolers, use these air coolers wherever air conditioning is impractical. They take in water, which soaks into pads. When air is blown through the wet pads, the evaporation produces cool air. These air coolers have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. All have a NEMA 5-15 plug, which is a standard three-prong plug.
    Air Coolers
    Replacement Pads
    Replacement
    Pumps
    Overall
    Inlet
    Hose
    Pads
    Airflow,
    ft³/min
    Reservoir
    Cap., gal.
    No. of
    Speeds
    Power,
    hp
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Size
    Thread
    Type
    Housing
    Material
    No.
    Required
    No.
    Included
    Each
    Pkg.
    Qty.
    Pkg.
    Each
    120V AC, Single Phase—NEMA 5-15, 3-Blade Plug In
    3,10010.3Variable1/52.438"24"16"3/4GHT
    Plastic330000000000000030000000000000000000000000000
     

    Belt-Drive Hazardous Location Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Hazardous Location Duct Fans.
    These fans have an explosion-proof motor that is rated for hazardous environments. All are belt-drive fans that are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. UL and CSA standards apply to the motor.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    IP56 Enclosure Rating— Fans rated IP56 have a motor enclosure that’s rated for protection in damp, dusty, and washdown environments.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
     
    IP56 Enclosure Rating
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    UL Listed
    No7/16"0000000000000000
     

    Wall-Mount Jet-Stream Fans

    Often used to cool warehouse aisles and production lines, these fans generate a stream of air that travels farther than air from conventional fans. They have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Wall-Mount Jet-Stream Fans.
    Blade
    Overall
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Drive
    Type
    Housing
    Material
    Guard
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    208-230/460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    22"Aluminum5,500 ft³/min66 dBA @ 15 ft.1,72511/22.4 amp
    1.2 amp
    32"29"15"DirectPolypropyleneSteelYes5/8"0000000000000000
     

    Belt-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Duct Fans.
    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    No7/16"0000000000000000
     

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"5,20069 dBA @ 5 ft.Direct1,12511/231 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors

    High-Visibility Pedestal Fans

    A bright yellow guard makes these fans easy to spot. All fans have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance.
    Fans with Open Motor Enclosure
    Image of Product. 20" Blade Dia.. Front orientation. Contains Annotated. 20" Diameter Blade. High-Visibility Pedestal Fans.

    20" Blade Dia.

    Blade
    Guard
    Pedestal
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.,
    ft.
    Cord Lg.,
    ft.
    Drive
    Type
    Material
    Color
    Material
    Color
    Certification
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    20"Galvanized Steel4,200 ft³/min60 dB @ 5 ft.1,10021/42.4 amp518DirectPowder-Coated SteelYellowPowder-Coated SteelYellowETL Listed
    00000000000000
     
    Fan Energy-Saving Modules

    Belt-Drive Corrosion-Resistant Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Corrosion-Resistant Duct Fans.
    A 304 stainless steel housing offers good corrosion resistance. All of these belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing Material
    Blade Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
    18"14,600 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,3501 1/220 1/16"32 11/16"20"200304 Stainless SteelStainless Steel
    No7/16"0000000000000000
     

    Oil- and Coolant-Removing Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Oil- and Coolant-Removing Air Purifiers.
    Image of Product. Front orientation. Air Purifier Filters.

    Replacement Filters

    Often used in machine shops, these purifiers remove oil and coolant mist from the air. Air passes through a spinning drum.
    Purifiers
    Replacement
    Filters
    Overall
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    For Inlet
    Duct Dia.
    Ht.
    Wd.
    Dp.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Housing
    Material
    No. of
    Speeds
    Includes
    For
    Removing
    Each
    Each
    16556 dB @ 15 ft.1/2208V AC
    240V AC
    460V AC
    1.1 amp
    2.2 amp
    2.4 amp
    4"19"15"15"No9/16"Steel1Disposable Filter (Captures 98% of mist particles down to 1 micron)Oil, Coolant0000000000000000000000000000

    High-Output Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    750 ft³/min @ 5 in. H₂O
    850 ft³/min @ 3 in. H₂O
    76 dBA @ 15 ft.3,45025"6"12"18 1/4"17 5/16"17 5/16"884.9 amp/2.4 amp-10 to 150AluminumNo7/16"0000000000000000
     
    back to top