About Exhaust Fans
More
About Calculating the Airflow Required for Air Cleaning
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Hanging Box Fans
Easily hang these fans from your ceiling using the attached bracket and a mounting chain kit (sold separately). They're more powerful than our standard box fans. Made with a heavy duty 12-gauge welded wire mesh guard, these fans will stand up to tough environments. Plastic guard clips help reduce vibration between the housing and the guard, making these fans quieter. They require little maintenance thanks to their totally enclosed, high-efficiency motor and sealed ball bearings.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Voltage (Current) | Power, hp | Ht. | Wd. | Dp. | Drive Type | Housing Material | Blade Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
Three Phase—Hardwire | |||||||||||||||
Non-Oscillating | |||||||||||||||
24" | 5,000 | 850 | 1 | 240V AC (2.6 A) 460V AC (1.3 A) | 1/2 | 30 1/2" | 30 1/2" | 16 1/4" | Direct | Galvanized Steel | Steel | No | 3/8" | 0000000 | 0000000 |
36" | 9,800 | 850 | 1 | 240V AC (2.6 A) 460V AC (1.3 A) | 1/2 | 40 5/8" | 40 5/8" | 14 1/8" | Direct | Galvanized Steel | Steel | No | 3/8" | 0000000 | 000000 |
Chains | ||||
---|---|---|---|---|
No. of | Lg. | Includes | Each | |
3 | 72" | Six Threaded Connecting Links, Three Eyebolts, Six Nuts for Eyebolts | 0000000 | 000000 |
Pedestal Fan Motors
Build your own fan or replace a fan motor. Mount one of these motors directly to a fan column. Four 8-32 threaded mounting studs extend 1" for mounting a fan guard.
View information about motors.
Note: When selecting a fan blade, be sure the rpm and hp are compatible and the shaft diameter of the blade matches the shaft diameter of the motor.
For technical drawings and 3-D models, click on a part number.
Shaft | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor Speed, rpm | Power, hp | Dia. | Lg. | Current, A | Lg. | Ht. | Wd. | Direction of Operation | Service Factor | Mount. Fasteners Included | Mount. Hole Dia. | Features | Specifications Met | Each | |
NEMA 48YZ | |||||||||||||||
120V AC, Single Phase—Hardwire | |||||||||||||||
1,625 | 1/4 | 1/2" | 2 3/8" | 2.6 | 10 11/16" | 10 3/8" | 5 11/16" | Clockwise or Counterclockwise | 1.0 | No | 7/16" | Thermal Overload Protection | UL Recognized Component, CSA Certified | 0000000 | 0000000 |
Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans
Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers
These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For Opening | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Ambient Temperature | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Specifications Met | Each | |
230/460V AC, Three Phase—Hardwire | |||||||||||||||||
30" | 5,745 | 850 | 1 | 1/2 | 30 1/2" | 30 1/2" | 33" | 33" | 15 1/4" | 100° F | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 0000000 |
Exterior-Wall-Mount Exhaust Fans
Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain. Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow @ Static Pressure | Drive Type | Motor Speed, rpm | Power, hp | Dia. | Ht. | Wd. | Dia. | Dp. | Motor Enclosure Type | Includes | Each | |
230/460V AC, Three Phase—Hardwire | |||||||||||||
36" | 6,700 cfm @ 0.2 in. of H₂O 11,200 cfm @ 0 in. of H₂O | Direct | 825 | 1/2 | 36" | 44" | 44" | 53" | 57" | Totally Enclosed | Louvers | 0000000 | 000000000 |
Hazardous Location Exhaust Fans
These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
Fans that cannot be sold to California do not meet energy efficiency requirements.
Fans | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | ||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Drive Type | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Housing Material | Blade Material | Environmental Rating | Cannot Be Sold To | Each | Each | ||
230/460V AC, Three Phase—Hardwire | |||||||||||||||||
30" | 11,000 | 77 dBA @ 5 ft. | Direct | 1,125 | 1 | 1 1/2 | 36 1/8" | 36 1/8" | 29 1/4" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | CA | 0000000 | 000000000 | 0000000 | 0000000 |
Belt-Drive Corrosion-Resistant Duct Fans
A 304 stainless steel housing offers good corrosion resistance. All of these belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Dp. | Max. Temp., °F | Housing Material | Blade Material | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
12" | 1,600 cfm @ 3/8 in. of H₂O 1,800 cfm @ 1/8 in. of H₂O | 60 dBA @ 15 ft. | 3,050 | 3/4 | 14 1/16" | 25 5/8" | 20" | 200° | 304 Stainless Steel | Stainless Steel | No | 7/16" | 0000000 | 000000000 |
High-Output Blowers
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard blowers can handle. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, drying, ventilating, and exhausting. Blowers that weigh 280 lbs. or less can also be used for material conveying. Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
High-Output Blowers | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | ||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Each | Each | ||
Totally Enclosed Motor Enclosure | |||||||||||||||
120/230V AC, Single Phase—Hardwire | |||||||||||||||
120 cfm @ 5 in. of H₂O 315 cfm @ 3 in. of H₂O | 65 dBA @ 15 ft. | 3,450 | 1/3 | 3 15/16" | 5" | 9" | 17 3/4" | 15 5/16" | 14 1/4" | 58 | -10° to 150° | 0000000 | 000000000 | 0000000 | 0000000 |
High-Output Blowers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Replacement Wheels | ||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Each | Each | ||
Totally Enclosed Motor Enclosure | ||||||||||||||||
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dBA @ 15 ft. | 3,450 | 3/4 | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | 39 | -15° to 180° | 0000000 | 0000000 | 0000000 | 0000000 |
Corrosion-Resistant Blowers
A 304 stainless steel housing offers good corrosion resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Outlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure | |||||||||||||||
230/460V AC, Three Phase—Hardwire | |||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dBA @ 15 ft. | 3,450 | 3/4 | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | -15° to 180° | No | 3/8" | 0000000 | 000000000 |
Ceiling-Mount Office Air Cleaners
Reusable prefilter can be washed.
Reusable electrostatic filter has an inherent electrostatic charge attracts particles. It can be washed.
For Ceiling Tile | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Lg. | Wd. | Lg. | Ht. | Wd. | Housing Material | Includes | For Removing | Cannot Be Sold To | Each | |
White Housing | ||||||||||||||
650 | 45 dB @ 15 ft. | 120V AC | 2.6A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable Odor-Removal After-Filter, Reusable Electrostatic Filter (Captures 97% of particles down to 0.01 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 000000000 |
Black Housing | ||||||||||||||
650 | 45 dB @ 15 ft. | 120V AC | 2.6A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable Odor-Removal After-Filter, Reusable Electrostatic Filter (Captures 97% of particles down to 0.01 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 00000000 |