    11 Products

    Fire Alarm Control Panels

    Image of Product. Front orientation. Control Panels. Fire Alarm Control Panels.
    Connect and monitor your fire alarm system. Control panel comes with all the circuitry needed to power and monitor devices for up to five zones. These devices can include up to 30 smoke or carbon monoxide detectors as well as an unlimited number of heat detectors and fire alarm stations. Indicators show the status of each zone. The control panel has one relay for connecting alarms such as buzzers, bells, and lights.
    The control panel requires two 12-volt batteries (not included) for operation; in case of power failure, it will use the batteries as a backup power source.
    Batteries
    For Max. No.
    of Zones
    For Max. No.
    of Detectors
    Ht.
    Wd.
    Dp.
    Material
    Color
    Electrical
    Connection
    Voltage,
    V AC
    Included
    No.
    Req.
    Voltage,
    V DC
    Certification
    Each
    53019 1/2"14 1/4"3 3/4"SteelRedScrew Terminal120No212UL Listed
    6634T770000000

    Fire Alarm Stations

    Image of Product. Front orientation. Fire Alarm Pull Stations. Fire Alarm Stations, Push-Button Activation.
    Image of Product. Front orientation. Fire Alarm Pull Stations. Fire Alarm Stations, Pull-Handle Activation.
    Image of Product. Front orientation. Fire Alarm Pull Stations. Fire Alarm Stations, Lift-and-Pull Handle Activation.

    Push-Button

    Activation

    Pull-Handle

    Activation

    Lift-and-Pull

    Handle

    Activation

    Install these stations throughout your facility for quick access in case of a fire. When activated, they send a signal to your control panel.
    Push-Button Activation—Push-button station helps comply with ADA standards when properly installed.
    Fire Alarm Pull Stations
    Replacement
    Fire Alarm Rods
    Ht.
    Wd.
    Dp.
    Material
    Color
    Certification
    Each
    Each
    Push-Button Activation
    6"4 3/8"1 3/4"PlasticRedUL Listed
    6597T19000000———0
     
    Pull-Handle Activation
    4 1/2"3 1/4"1"IronRedUL Listed
    6652T11000006652T1200000
     
    Lift-and-Pull Handle Activation
    5 1/4"3 1/2"1 3/8"PlasticRedUL Listed
    6652T21000006652T220000
     

    Heat Detectors

    Image of Product. Front orientation. Heat Detectors. Heat Detectors.
    When temperatures get too high, these alarms sound off. Use them in garages, boiler rooms, and other areas where dust, debris, or light smoke can set off false smoke alarms. Wire them directly into your building’s electrical system. You can also link multiple alarms in tandem, so if one detects heat, they all go off. A backup battery keeps them working during power outages.
    Mounting
    Holes
    Activation
    Temp., ° F
    Volume (Sound)
    @ Distance
    Wire
    Connection
    No. of Wire
    Leads
    Voltage,
    V AC
    Dia.
    Dp.
    Max. No. of Tandem
    Detectors
    Tandem Signaling
    Capable
    Batteries
    Included
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Certification
    Flammability
    Rating
    Includes
    Each
    13585 dBA @ 10 ft.Wire Leads31205"2"18YesYesNo61/4"California Fire Marshal Approved
    UL 539Mounting Plate, Wire Connector3522N12000000
     

    Heat Detectors for Fire Alarm Systems

    Image of Product. Front orientation. Heat Detectors. Heat Detectors for Fire Alarm Systems, Indoor-Only Environments.
    Image of Product. Front orientation. Heat Detectors. Heat Detectors for Fire Alarm Systems, Outdoor Environments.

    Indoor-Only Environments

    Outdoor

    Environments

    When the temperature climbs above the temperature rating, the detector sends a signal to your control panel.
    Temp. Rating,
    ° F
    No. of Wire
    Leads
    Voltage
    Current @ Voltage
    Dia.
    Dp.
    Tandem Signaling
    Capable
    Electrical
    Connection
    Certification
    Each
    Indoor-Only Environments
    13512V DC
    24V DC
    120V AC
    1 amp @ 12V DC
    1 amp @ 24V DC
    3 amp @ 120V AC
    4 9/16"1 11/16"NoScrew TerminalFM Approved, UL Listed
    6651T73000000
    19412V DC
    24V DC
    120V AC
    1 amp @ 12V DC
    1 amp @ 24V DC
    3 amp @ 120V AC
    4 9/16"1 11/16"NoScrew TerminalFM Approved, UL Listed
    6651T7400000
     
    Outdoor Environments
    135412V DC
    24V DC
    120V AC
    1 amp @ 12V DC
    1 amp @ 24V DC
    5 amp @ 120V AC
    2"4 1/8"NoWire LeadsFM Approved, UL Listed
    6651T7600000
    194412V DC
    24V DC
    120V AC
    1 amp @ 12V DC
    1 amp @ 24V DC
    5 amp @ 120V AC
    2"4 1/8"NoWire LeadsFM Approved, UL Listed
    6651T7700000
     