McMaster-Carr logo
    Filter by
    System of Measurement
    DFARS Specialty Metals
    Power Source
    Sound Pattern
    Mounting Hole Diameter
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Number of Programmable Tones
    Volume Control
    Fasteners Included
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    28 Products

    Hazardous Location Multiple-Tone Horns

    Image of Product. Front orientation. Contains Annotated. Audible Alarms. Hazardous Location Multiple-Tone Horns.
    Horns are UL and C-UL listed for indoor and outdoor use in Class I, Division 2, Groups A, B, C, and D; Class II, Division 2, Groups F and G, and Class III, Division 2 hazardous locations. You can select up to three programmable tones, each corresponding to a different warning. If multiple signals are triggered at once, only the highest priority signal will sound.
    Knockouts
    Mounting
    Holes
    No. of Programmable
    Tones
    Voltage
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Sound
    Pattern
    Ht.
    Wd.
    Dp.
    Material
    No.
    of
    Trade
    Size
    Fasteners
    Included
    No.
    of
    Dia.
    Each
    Terminal Block Connection
    324V DC
    120V AC
    240V AC
    0.5 amp @ 24V DC
    0.21 amp @ 120V AC
    0.12 amp @ 240V AC
    110.5 dBA @ 10 ft.Continuous13.9"10.2"10"Aluminum21/2
    No43/16"5823T43000000000
     

    Fire Alarm Horns with Strobe Light

    In addition to loud beeps, these horns use flashing lights to warn you to evacuate during a fire. Connect them to your fire detection system, and a signal from your control panel will set them off. They help you comply with NFPA 72 standards for fire alarm systems.
    All horns must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a horn that includes an outlet box.
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Horns rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    212
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    110
    150
    177
    185
    Fire7 3/4"5 3/4"1 5/8"YesFire Alarm PlatesADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T11000000071695K13000008731N150000008733N1700000
    812
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 5/8"YesFire Alarm PlatesADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T1200000071695K1300008731N15000008733N170000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated horns come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    212
    24
    0.034 amp @ 12V DC
    0.038 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    95
    110
    150
    177
    185
    Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T1300000008731N150000008733N1700000
    812
    24
    0.034 amp @ 12V DC
    0.038 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T140000008731N15000008733N170000
     

    Fire Alarm Strobe Lights

    Draw attention to fires with bright, flashing lights. Connect these lights to your fire detection system, and a signal from your control panel will trigger them. They’re often used in small spaces, where noise from bells or horns would exceed safe decibel levels, or in extremely loud areas. They help you comply with NFPA 72 standards for fire alarm systems.
    All lights must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a light that includes an outlet box.
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall

    Mount/Ceiling

    Mount

    Lights rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Lights with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 3/4"YesFire Alarm PlatesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N13000000071695K13000008731N150000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall

    Mount/Ceiling

    Mount

    NEMA 4X-rated lights come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Lights with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 3/8"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N1400000008731N150000008733N1700000
     

    Adjustable-Volume Multiple-Tone Horns

    Image of Attribute. Front orientation. Contains Annotated. Adjustable-Volume Multiple-Tone Horns.
    Mounting
    Holes
    Voltage
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Sound Pattern
    Ht.
    Wd.
    Dp.
    Material
    Conduit
    Trade Size
    Thread
    Type
    Gender
    Fasteners
    Included
    No.
    of
    Dia.
    Each
    Screw Terminal Connection
    24V AC
    24V DC
    1.1 amp @ 24V AC
    1.1 amp @ 24V DC
    0 dBA to 110 dBA @ 10 ft.Continuous, Pulse12 1/2"8"8 1/2"Aluminum1/2
    NPT
    FemaleNo23/16"5682T650000000
    120V AC0.3 amp @ 120V AC0 dBA to 110 dBA @ 10 ft.Continuous, Pulse12 1/2"8"8 1/2"Aluminum1/2
    NPT
    FemaleNo23/16"5682T67000000
     

    Hazardous Location Buzzers

    Image of Product. Front orientation. Audible Alarms. Hazardous Location Buzzers.
    Buzzers are UL Listed for Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 environments where flammable gases, combustible dust, and combustible fibers may be present.
    Volume
    Mounting
    Holes
    Voltage
    Current @ Voltage
    Control
    (Sound) @
    Distance
    Environment
    Sound
    Pattern
    Power
    Source
    Ht.
    Wd.
    Dp.
    Material
    Conduit
    Trade Size
    Thread
    Type
    Gender
    Mounting
    Profile
    Fasteners
    Included
    No.
    of
    Dia.
    Includes
    Certification
    Each
    With 3 Wire Leads
    24V DC0.16 amp @ 24V DCFixed97 dBA @ 10 ft.Corrosive, Dusty, Hazardous, Outdoor, Washdown, WetContinuousElectric7 5/8"7 3/8"4 1/4"Zinc3/4
    NPT
    FemaleSurfaceNo23/8"Two Mounting BracketsUL Listed
    5650T32000000000
    120V AC0.13 amp @ 120V ACFixed100 dBA @ 10 ft.Corrosive, Dusty, Hazardous, Outdoor, Washdown, WetContinuousElectric7 5/8"7 3/8"4 1/4"Zinc3/4
    NPT
    FemaleSurfaceNo23/8"Two Mounting BracketsUL Listed
    5650T2300000000
     

    Fire Alarm Horns

    These horns warn you of a fire with loud beeps. Connect them to your fire detection system, and a signal from your control panel will set them off. They help you comply with NFPA 72 standards for fire alarm systems.
    All horns must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a horn that includes an outlet box.
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Horns rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Indoor Boxes
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    212
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.Fire7 3/4"5 3/4"1 1/2"YesFire Alarm PlatesADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N2300000071695K13000008733N1700000
    812
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    65 dBA to 88 dBA @ 10 ft.Fire7 3/4"5 3/4"1 1/2"YesFire Alarm PlatesADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N2400000071695K1300008733N170000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated horns come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    212
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N250000008733N1700000
    812
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    65 dBA to 88 dBA @ 10 ft.Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N260000008733N170000
     

    Fire Alarm Speakers

    When a fire breaks out, these speakers broadcast instructions. Connect them to your fire detection system and use your control panel to program the message. These speakers help you comply with NFPA 72 standards for fire alarm systems.
    All speakers must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a speaker that includes an outlet box.
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Speakers rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Indoor Boxes
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    240.2 amp @ 24V DC76 dBA to 94 dBA @ 10 ft.Fire7 3/4"5 3/4"1 3/4"YesFire Alarm PlatesADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728721N21000000071695K13000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated speakers come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    240.2 amp @ 24V DC76 dBA to 94 dBA @ 10 ft.Fire8"6 1/2"4 3/8"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728721N2200000008733N1700000
     

    Fire Alarm Speakers with Strobe Light

    These speakers broadcast instructions and flash bright lights to warn you of a fire. Connect them to your fire detection system and use your control panel to program the message. They help you comply with NFPA 72 standards.
    All speakers must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a speaker that includes an outlet box.
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Speakers rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC75 dBA to 88 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 1/2"YesFire Alarm PlatesADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728937N13000000071695K13000008731N150000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated speakers come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC75 dBA to 88 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728937N1400000008731N150000008733N1700000
     

    Washdown Buzzers

    Buzzers meet NEMA 4X for protection and corrosion resistance in washdown environments.
    Panel Mount
    Image of Product. Front orientation. Audible Alarms. Washdown Buzzers, Panel Mount.
    For Panel
    Cutout
    Voltage
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Sound
    Pattern
    Ht.
    Wd.
    Dp.
    Material
    Ht.
    Wd.
    Fasteners
    Included
    Enclosure
    Rating
    Each
    With 2 Wire Leads
    24V AC0.9 amp @ 24V AC94 dB to 100 dB @ 10 ft.Continuous5 5/8"5 5/8"2 3/8"Zinc3 1/8"3 1/8"YesNEMA 12
    NEMA 4X
    3038T180000000
    120V AC0.22 amp @ 120V AC94 dB to 100 dB @ 10 ft.Continuous5 5/8"5 5/8"2 3/8"Zinc3 1/8"3 1/8"YesNEMA 12
    NEMA 4X
    3038T22000000
     
    With 4 Wire Leads
    24V DC0.25 amp @ 24V DC99 dBA @ 10 ft.Continuous4 1/8"4 1/8"2 7/8"Polycarbonate3 1/8"3 1/8"YesNEMA 4X
    3038T29000000
     
    Surface Mount
    Image of Product. Front orientation. Contains MultipleImages. Audible Alarms. Washdown Buzzers, Surface Mount.
    Voltage
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Sound
    Pattern
    Ht.
    Wd.
    Dp.
    Material
    Conduit Trade
    Size
    Thread
    Type
    Fasteners
    Included
    Includes
    Enclosure
    Rating
    Each
    With Screw Terminal Connection
    120V AC0.18 amp @ 120V AC94 dB to 100 dB @ 10 ft.Continuous4 1/2"4 1/2"3 3/8"Aluminum3/4
    NPT
    YesOutlet BoxNEMA 4X
    3038T380000000
     
    With 2 Wire Leads
    24V AC0.9 amp @ 24V AC94 dB to 100 dB @ 10 ft.Continuous4 1/2"6"3 5/8"Zinc1/2, 3/4
    NPT
    YesOutlet BoxNEMA 4X
    3038T13000000
     
    With 4 Wire Leads
    24V DC0.25 amp @ 24V DC99 dBA @ 10 ft.Continuous4 3/8"5"3 7/8"Polycarbonate3/4
    NPT
    YesOutlet BoxNEMA 4X
    3038T41000000
     
    back to top