    61 Products

    Fire Alarm Horns with Strobe Light

    In addition to loud beeps, these horns use flashing lights to warn you to evacuate during a fire. Connect them to your fire detection system, and a signal from your control panel will set them off. They help you comply with NFPA 72 standards for fire alarm systems.
    All horns must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a horn that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    No. of Programmable
    Tones
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    2240.2 amp @ 24V DC86 dBA to 91 dBA @ 10 ft.15
    30
    75
    110
    135
    185
    Fire4 3/4"2 3/4"1 3/16"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T1100000071695K26000008731N15000000
    8240.32 amp @ 24V DC81 dBA to 99 dBA @ 10 ft.15
    30
    75
    110
    135
    185
    Fire4 3/4"2 3/4"1 1/4"YesADA Compliant
    UL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    NFPA 7283005T3800000071695K1300008731N1500000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    2240.2 amp @ 24V DC86 dBA to 91 dBA @ 10 ft.15
    30
    75
    150
    177
    Fire6 1/4"1 7/8"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T120000071695K2600008731N1500000
    8240.16 amp @ 24V DC92 dBA to 99 dBA @ 10 ft.15
    30
    75
    150
    177
    Fire6 1/4"1 3/4"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T1300000071695K1300008731N1500000
     
    Indoor Only—Low Frequency
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor-Only Environments, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor-Only Environments, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Low-frequency horns are better at waking sleepers than standard horns. They’re also more likely to reach individuals with hearing impairments.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    No. of Programmable
    Tones
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity,
    cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    3240.25 amp @ 24V DC80 dBA @ 10 ft.110
    177
    Fire6 3/8"4 1/2"1 1/2"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T14000000071695K13000008731N15000000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    3240.25 amp @ 24V DC80 dBA @ 10 ft.110
    177
    Fire6 1/4"2 1/4"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T1500000071695K1300008731N1500000
     
    Indoor, Outdoor
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor, Outdoor, Wall Mount.

    Wall Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Outdoor Boxes
    Sync Modules
    No. of Programmable
    Tones
    Voltage,
    V AC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Light Intensity,
    cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Each
    Wall Mount
     
    Gray Plastic—With Xenon Bulb
    81200.05 amp @ 120V AC74 dBA to 89 dBA @ 10 ft.154"4"2 1/4"YesUL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    UL Listed
    NFPA 7259835T19000000071695K130000059835T340000008731N15000000
     
    Red Plastic—With Xenon Bulb
    81200.05 amp @ 120V AC74 dBA to 89 dBA @ 10 ft.15Fire4"4"2 1/4"YesUL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    UL Listed
    NFPA 7259835T1700000071695K13000059835T34000008731N1500000
     
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Horns rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    212
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    110
    150
    177
    185
    Fire7 3/4"5 3/4"1 5/8"YesFire Alarm PlatesADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T11000000071695K13000008731N150000008733N1700000
    812
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 5/8"YesFire Alarm PlatesADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T1200000071695K1300008731N15000008733N170000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated horns come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    212
    24
    0.034 amp @ 12V DC
    0.038 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    95
    110
    150
    177
    185
    Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T1300000008731N150000008733N1700000
    812
    24
    0.034 amp @ 12V DC
    0.038 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 722684T140000008731N15000008733N170000
     

    Smoke Detectors

    At the first sign of smoke, these smoke detectors sound off. They have built-in sensors, so you don’t need to connect them to a fire detection system.
    Battery Powered
    Image of Product. Front orientation. Smoke Detectors. Smoke Detectors, Battery Powered.
    Cannot Be Sold to Canada—Due to import regulations, this smoke detector cannot be sold to Canada.
    Each
    Package
    Volume (Sound)
    @ Distance
    Dia.
    Dp.
    Tandem Signaling
    Capable
    Batteries
    Included
    Mounting Fasteners
    Included
    Includes
    Features
    Specs.
    Met
    Certification
    Cannot Be
    Sold To
    Each
    Pkg.
    Qty.
    Pkg.
    Replaceable Batteries
    85 dBA @ 10 ft.4"1 1/2"NoYesYesDust Cover
    Mounting Plate
    Hush/Test ButtonUL 217ETL Listed
    Canada1032N1300000031032N14000000
     
    Nonreplaceable 10 yr. Batteries
    85 dBA @ 10 ft.5"2"NoYesNoDust Cover
    Mounting Plate
    Hush/Test ButtonUL 217California Fire Marshal Approved
    Canada1032N1200000———0
     
    Smoke Detector Guards
    Hardwired with Battery Backup
    Image of Product. Front orientation. Smoke Detectors. Smoke Detectors, Hardwired with Battery Backup.
    Wi-Fi Connection—Detectors with Wi-Fi connection pair with an app on your smartphone, so you can respond to an emergency even when you’re offsite. They send you notifications if they detect smoke or the battery is running low.
    Tandem Signaling Capable—Detectors with tandem signaling can be linked together so that if one detects smoke, they all go off. They install directly into your facility’s electrical system. All have a backup battery to keep them working during power outages.
    Voice Alerts: Fire and Low Battery and Voice Alerts: Fire, Warning-Carbon Monoxide, and Low Battery—Detectors with voice alerts don’t just beep—they explain whether there’s smoke or the batteries need changing.
    Cannot Be Sold to Canada—Due to import regulations, this smoke detector cannot be sold to Canada.
    Tandem
    Signaling
    Wire
    Each
    Package
    Volume (Sound)
    @ Distance
    Dia.
    Dp.
    Capable
    Max. No. of
    Detectors
    Voltage,
    V AC
    Connection
    No. of
    Leads
    Batteries
    Included
    Mounting Fasteners
    Included
    Includes
    Features
    Specs.
    Met
    Certification
    Cannot Be
    Sold To
    Each
    Pkg.
    Qty.
    Pkg.
    Replaceable Batteries
    85 dBA @ 10 ft.5.25"1 1/2"Yes12120Wire Leads3YesYesDust Cover
    Mounting Plate
    Hush/Test ButtonUL 217California Fire Marshal Approved, ETL Listed
    Canada1032N1500000031032N16000000
     
    Replaceable Batteries—Wi-Fi Connection
    85 dBA @ 10 ft.5"2"Yes12120Wire Leads3YesNoDust Cover
    Mounting Plate
    Wire Connector
    Hush/Test Button; Voice Alerts:
    Fire and Low Battery
    UL 217California Fire Marshal Approved
    Canada1032N1900000———0
     
    Nonreplaceable 10 yr. Batteries
    85 dBA @ 10 ft.6 1/4"1 1/2"Yes12120Wire Leads3YesYesDust Cover
    Mounting Plate
    Wire Connector
    Hush/Test Button; Voice Alerts:
    Fire, Warning-Carbon Monoxide,
    and Low Battery
    UL 217California Fire Marshal Approved, ETL Listed
    Canada1032N170000031032N18000000
     
    Smoke Detector Guards

    Smoke Detectors with Strobe Light

    Image of Product. Front orientation. Smoke Detectors. Smoke Detectors with Strobe Light.
    When smoke is present, these detectors warn you with loud beeps and flashing lights. Use them alone or link several together so that if one detects smoke, they all go off in tandem. They install directly into your facility’s electrical system. These detectors also have a backup battery to keep them working during power outages.
    Hardwired with Battery Backup
    Cannot Be Sold to Canada—Due to import regulations, this smoke detector cannot be sold to Canada.
    Tandem
    Signaling
    Wire
    Volume (Sound)
    @ Distance
    Dia.
    Dp.
    Capable
    Max. No. of
    Detectors
    Voltage,
    V AC
    Connection
    No. of
    Leads
    Batteries
    Included
    Mounting Fasteners
    Included
    Includes
    Features
    Specs. Met
    Certification
    Cannot Be
    Sold To
    Each
    Nonreplaceable 10 yr. Batteries
    85 dBA @ 10 ft.5 1/4"2 5/16"Yes12120Wire Leads3YesYesMounting Plate
    Wire Connector
    Hush/Test ButtonUL 217, UL 1638California Fire Marshal Approved, ETL Listed
    Canada6668T160000000
     
    Smoke Detector Guards

    Fire Alarm Speakers with Strobe Light

    These speakers broadcast instructions and flash bright lights to warn you of a fire. Connect them to your fire detection system and use your control panel to program the message. They help you comply with NFPA 72 standards.
    All speakers must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a speaker that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    240.18 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.15
    30
    75
    110
    135
    185
    Fire6 3/8"4 1/2"1 1/2"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728937N11000000071695K13000008731N15000000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.18 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.15
    30
    75
    110
    150
    177
    Fire6 1/4"1 1/2"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728937N1200000071695K1300008731N1500000
     
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Speakers rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC75 dBA to 88 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 1/2"YesFire Alarm PlatesADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728937N13000000071695K13000008731N150000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated speakers come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC75 dBA to 88 dBA @ 10 ft.15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728937N1400000008731N150000008733N1700000
     

    Fire Alarm Strobe Lights

    Draw attention to fires with bright, flashing lights. Connect these lights to your fire detection system, and a signal from your control panel will trigger them. They’re often used in small spaces, where noise from bells or horns would exceed safe decibel levels, or in extremely loud areas. They help you comply with NFPA 72 standards for fire alarm systems.
    All lights must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a light that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    240.16 amp @ 24V DC15
    30
    75
    110
    135
    185
    Fire4 3/4"2 3/4"1 1/8"YesUL 464
    UL 1638
    UL 1971
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N1100000071695K26000008731N15000000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.16 amp @ 24V DC15
    30
    75
    110
    150
    177
    Fire6 1/4"1 5/8"YesUL 464
    UL 1638
    UL 1971
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N120000071695K2600008731N1500000
     
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall

    Mount/Ceiling

    Mount

    Lights rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Lights with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 3/4"YesFire Alarm PlatesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N13000000071695K13000008731N150000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall

    Mount/Ceiling

    Mount

    NEMA 4X-rated lights come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Lights with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 3/8"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N1400000008731N150000008733N1700000
     

    Smoke and Carbon Monoxide Detectors

    When smoke curls or carbon monoxide rises, these detectors sound off. They have built-in sensors, so you don’t need to connect them to a fire detection system. All have voice alerts that explain why the alarm is sounding.
    Battery Powered
    Image of Product. Front orientation. Smoke Detectors. Smoke and Carbon Monoxide Detectors, Battery Powered.
    Volume (Sound)
    @ Distance
    Dia.
    Dp.
    Tandem Signaling
    Capable
    Batteries
    Included
    Mounting Fasteners
    Included
    Includes
    Features
    Specs. Met
    Certification
    Each
    Replaceable Batteries
    85 dBA @ 10 ft.6 1/8"1 5/8"NoYesYesDust Cover
    Mounting Plate
    Audible Alarm; Hush/Test Button;
    Voice Alerts: Fire,
    Warning-Carbon Monoxide,
    and Low Battery
    UL 217, UL 2034ETL Listed
    8972N11000000
     
    Nonreplaceable 10 yr. Batteries
    85 dBA @ 10 ft.6 1/8"1 5/8"NoYesYesDust Cover
    Mounting Plate
    Audible Alarm; Hush/Test Button;
    Voice Alerts: Fire,
    Warning-Carbon Monoxide,
    and Low Battery
    UL 217, UL 2034ETL Listed
    8972N1200000
     
    Smoke Detector Guards
    Hardwired with Battery Backup
    Image of Product. Front orientation. Smoke Detectors. Smoke and Carbon Monoxide Detectors, Hardwired with Battery Backup.
    Wi-Fi Connection—Detectors with Wi-Fi connection pair with an app on your smartphone, so you can respond to an emergency even when you’re offsite. They send you notifications if they detect a hazard or the battery is running low.
    Tandem Signaling Capable—Detectors with tandem signaling can be linked together so that if one spots smoke or carbon monoxide, they all go off. They install directly into your facility’s electrical system. All have a backup battery to keep them working during power outages.
    Cannot Be Sold to Canada—Due to import regulations, this smoke detector cannot be sold to Canada.
    Tandem
    Signaling
    Volume (Sound)
    @ Distance
    Dia.
    Dp.
    Capable
    Max. No. of
    Detectors
    No. of Wire
    Leads
    Batteries
    Included
    Mounting Fasteners
    Included
    Includes
    Features
    Specs. Met
    Certification
    Cannot Be
    Sold To
    Each
    Replaceable Batteries
    85 dBA @ 10 ft.6 1/8"1 5/8"Yes123YesYesDust Cover
    Mounting Plate
    Wire Connector
    Audible Alarm; Hush/Test Button;
    Voice Alerts: Fire,
    Warning-Carbon Monoxide,
    and Low Battery
    UL 217, UL 2034ETL Listed
    8972N13000000
     
    Replaceable Batteries—Wi-Fi Connection
    85 dBA @ 10 ft.5"1 7/8"Yes123YesNoDust Cover
    Mounting Plate
    Wire Connector
    Audible Alarm; Hush/Test Button;
    Voice Alerts: Fire,
    Warning-Carbon Monoxide,
    and Low Battery
    UL 217, UL 2034California Fire Marshal Approved
    Canada8972N1500000
     
    Nonreplaceable 10 yr. Batteries
    85 dBA @ 10 ft.6 1/8"1 5/8"Yes123YesYesDust Cover
    Mounting Plate
    Wire Connector
    Audible Alarm; Hush/Test Button;
    Voice Alerts: Fire,
    Warning-Carbon Monoxide,
    and Low Battery
    UL 217, UL 2034ETL Listed
    8972N1400000
     
    Smoke Detector Guards

    Fire Alarm Bells

    Image of Product. Front orientation. Fire Alarms. Fire Alarm Bells.
    When a fire starts, these bells ring loudly to warn you. They’re often mounted near sprinkler systems to help emergency responders locate the water hookup. Connect these bells to your fire detection system, and a signal from your control panel will set them off. They’ll ring as long as the signal is active—their motor vibrates to continuously strike the bell. They help you comply with NFPA 72 standards for fire alarm systems. All bells can be used indoors or outdoors.
    Indoor Boxes—Add an outlet box (sold separately) to mount the bell indoors, or mount to an existing outlet box.
    Outdoor Boxes—Outdoor boxes (sold separately) are lined with gaskets that seal water out and protect the wiring from temperature swings.
    Fire Alarms
    Indoor Boxes
    Outdoor Boxes
    Dia.
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    24V DC
     
    Red Enamel-Coated Aluminum
    6"0.03 amp @ 24V DC92 dBA @ 10 ft.YesUL 464
    ULC-S525
    California Fire Marshal Approved
    FM Approved
    NFPA 7249565T1500000071695K410000059835T34000000
    10"0.03 amp @ 24V DC92 dBA @ 10 ft.YesUL 464
    ULC-S525
    California Fire Marshal Approved
    FM Approved
    NFPA 7249565T160000071695K41000059835T3400000
     
    120V AC
     
    Red Powder-Coated Steel
    6"0.05 amp @ 120V AC99 dBA @ 10 ft.YesUL 464California Fire Marshal Approved
    ULC Listed
    NFPA 7249565T110000071695K41000049565T1400000
    8"0.05 amp @ 120V AC99 dBA @ 10 ft.YesUL 464California Fire Marshal Approved
    ULC Listed
    NFPA 7249565T120000071695K41000049565T1400000
    10"0.05 amp @ 120V AC99 dBA @ 10 ft.YesUL 464California Fire Marshal Approved
    ULC Listed
    NFPA 7249565T130000071695K41000049565T1400000
     
    Guards

    Fire Alarm Horns

    These horns warn you of a fire with loud beeps. Connect them to your fire detection system, and a signal from your control panel will set them off. They help you comply with NFPA 72 standards for fire alarm systems.
    All horns must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a horn that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Fire Alarms
    Indoor Boxes
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Wall Mount
     
    Red Plastic
    212
    24
    0.025 amp @ 12V DC
    0.028 amp @ 24V DC
    92 dBA to 99 dBA @ 10 ft.4 3/4"2 3/4"1 1/4"YesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    NFPA 728733N1100000071695K2600000
    812
    24
    0.2 amp @ 12V DC
    0.135 amp @ 24V DC
    92 dBA to 99 dBA @ 10 ft.4 3/4"2 3/4"1 1/4"YesADA Compliant
    UL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7259835T130000071695K130000
     
    Ceiling Mount
     
    Red Plastic
    212
    24
    0.025 amp @ 12V DC
    0.028 amp @ 24V DC
    92 dBA to 99 dBA @ 10 ft.6 1/4"1 1/4"YesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    NFPA 728733N120000071695K260000
     
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Horns rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Indoor Boxes
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    212
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.Fire7 3/4"5 3/4"1 1/2"YesFire Alarm PlatesADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N2300000071695K13000008733N1700000
    812
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    65 dBA to 88 dBA @ 10 ft.Fire7 3/4"5 3/4"1 1/2"YesFire Alarm PlatesADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N2400000071695K1300008733N170000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated horns come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Horns with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Replacement Fire
    Alarm Plates
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    212
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    74 dBA to 90 dBA @ 10 ft.Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N250000008733N1700000
    812
    24
    0.054 amp @ 12V DC
    0.052 amp @ 24V DC
    65 dBA to 88 dBA @ 10 ft.Fire8"6 1/2"4 1/2"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728733N260000008733N170000
     

    Adjustable-Volume Multiple-Tone Horns

    Image of Attribute. Front orientation. Contains Annotated. Adjustable-Volume Multiple-Tone Horns.
    Mounting
    Holes
    Voltage
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Sound Pattern
    Ht.
    Wd.
    Dp.
    Material
    Conduit
    Trade Size
    Thread
    Type
    Gender
    Fasteners
    Included
    No.
    of
    Dia.
    Each
    Screw Terminal Connection
    24V AC
    24V DC
    1.1 amp @ 24V AC
    1.1 amp @ 24V DC
    0 dBA to 110 dBA @ 10 ft.Continuous, Pulse12 1/2"8"8 1/2"Aluminum1/2
    NPT
    FemaleNo23/16"5682T650000000
    120V AC0.3 amp @ 120V AC0 dBA to 110 dBA @ 10 ft.Continuous, Pulse12 1/2"8"8 1/2"Aluminum1/2
    NPT
    FemaleNo23/16"5682T67000000
     

    Fire Alarm Speakers

    When a fire breaks out, these speakers broadcast instructions. Connect them to your fire detection system and use your control panel to program the message. These speakers help you comply with NFPA 72 standards for fire alarm systems.
    All speakers must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a speaker that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Fire Alarms
    Indoor Boxes
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Wall Mount
     
    Red Plastic
    240.16 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.Fire6 1/4"4 1/2"1 1/2"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728721N1100000071695K1300000
     
    Ceiling Mount
     
    Red Plastic
    240.16 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.Fire6 1/4"1 7/8"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728721N120000071695K130000
     
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    Speakers rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Indoor Boxes
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    240.2 amp @ 24V DC76 dBA to 94 dBA @ 10 ft.Fire7 3/4"5 3/4"1 3/4"YesFire Alarm PlatesADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728721N21000000071695K13000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall Mount/Ceiling

    Mount

    NEMA 4X-rated speakers come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Speakers with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Fire Alarms
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic
    240.2 amp @ 24V DC76 dBA to 94 dBA @ 10 ft.Fire8"6 1/2"4 3/8"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 1480
    UL 1638
    California Fire Marshal Approved
    FM Approved
    NFPA 728721N2200000008733N1700000
     