    28 Products

    Fire Alarm Horns with Strobe Light

    In addition to loud beeps, these horns use flashing lights to warn you to evacuate during a fire. Connect them to your fire detection system, and a signal from your control panel will set them off. They help you comply with NFPA 72 standards for fire alarm systems.
    All horns must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a horn that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    No. of Programmable
    Tones
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    2240.2 amp @ 24V DC86 dBA to 91 dBA @ 10 ft.15
    30
    75
    110
    135
    185
    Fire4 3/4"2 3/4"1 3/16"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T1100000071695K26000008731N15000000
    8240.32 amp @ 24V DC81 dBA to 99 dBA @ 10 ft.15
    30
    75
    110
    135
    185
    Fire4 3/4"2 3/4"1 1/4"YesADA Compliant
    UL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    NFPA 7283005T3800000071695K1300008731N1500000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    2240.2 amp @ 24V DC86 dBA to 91 dBA @ 10 ft.15
    30
    75
    150
    177
    Fire6 1/4"1 7/8"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T120000071695K2600008731N1500000
    8240.16 amp @ 24V DC92 dBA to 99 dBA @ 10 ft.15
    30
    75
    150
    177
    Fire6 1/4"1 3/4"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T1300000071695K1300008731N1500000
     
    Indoor Only—Low Frequency
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor-Only Environments, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor-Only Environments, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Low-frequency horns are better at waking sleepers than standard horns. They’re also more likely to reach individuals with hearing impairments.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    No. of Programmable
    Tones
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity,
    cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    3240.25 amp @ 24V DC80 dBA @ 10 ft.110
    177
    Fire6 3/8"4 1/2"1 1/2"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T14000000071695K13000008731N15000000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    3240.25 amp @ 24V DC80 dBA @ 10 ft.110
    177
    Fire6 1/4"2 1/4"YesADA Compliant
    UL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7283005T1500000071695K1300008731N1500000
     
    Indoor, Outdoor
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns with Strobe Light, Indoor, Outdoor, Wall Mount.

    Wall Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Outdoor Boxes
    Sync Modules
    No. of Programmable
    Tones
    Voltage,
    V AC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Light Intensity,
    cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Each
    Wall Mount
     
    Gray Plastic—With Xenon Bulb
    81200.05 amp @ 120V AC74 dBA to 89 dBA @ 10 ft.154"4"2 1/4"YesUL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    UL Listed
    NFPA 7259835T19000000071695K130000059835T340000008731N15000000
     
    Red Plastic—With Xenon Bulb
    81200.05 amp @ 120V AC74 dBA to 89 dBA @ 10 ft.15Fire4"4"2 1/4"YesUL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    UL Listed
    NFPA 7259835T1700000071695K13000059835T34000008731N1500000
     

    Fire Alarm Speakers with Strobe Light

    These speakers broadcast instructions and flash bright lights to warn you of a fire. Connect them to your fire detection system and use your control panel to program the message. They help you comply with NFPA 72 standards.
    All speakers must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a speaker that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers with Strobe Light, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Light Intensity, cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    240.18 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.15
    30
    75
    110
    135
    185
    Fire6 3/8"4 1/2"1 1/2"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728937N11000000071695K13000008731N15000000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.18 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.15
    30
    75
    110
    150
    177
    Fire6 1/4"1 1/2"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728937N1200000071695K1300008731N1500000
     

    Fire Alarm Strobe Lights

    Draw attention to fires with bright, flashing lights. Connect these lights to your fire detection system, and a signal from your control panel will trigger them. They’re often used in small spaces, where noise from bells or horns would exceed safe decibel levels, or in extremely loud areas. They help you comply with NFPA 72 standards for fire alarm systems.
    All lights must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a light that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Wall Mount
     
    Red Plastic—With LED Bulb
    240.16 amp @ 24V DC15
    30
    75
    110
    135
    185
    Fire4 3/4"2 3/4"1 1/8"YesUL 464
    UL 1638
    UL 1971
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N1100000071695K26000008731N15000000
     
    Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.16 amp @ 24V DC15
    30
    75
    110
    150
    177
    Fire6 1/4"1 5/8"YesUL 464
    UL 1638
    UL 1971
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N120000071695K2600008731N1500000
     
    Outdoor (IP54, NEMA 3R)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall

    Mount/Ceiling

    Mount

    Lights rated NEMA 3R are sealed to protect the wiring from dust, rain, and temperature swings.
    Fire Alarm Plates—Lights with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Indoor Boxes
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC15
    30
    75
    110
    150
    185
    Fire7 3/4"5 3/4"1 3/4"YesFire Alarm PlatesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N13000000071695K13000008731N150000008733N1700000
     
    Outdoor, Washdown (IP66, NEMA 4X)
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Strobe Lights, Outdoor Environments, Wall Mount/Ceiling Mount.

    Wall

    Mount/Ceiling

    Mount

    NEMA 4X-rated lights come mounted in a sealed outlet box. A gasket protects them from dust, heavy rain, temperature swings, and washdowns.
    Fire Alarm Plates—Lights with fire alarm plates have legible text regardless of how you mount them. They have removable plates with text on both sides—one vertical, the other horizontal.
    Sync Modules—Use sync modules (sold separately) to make lights in the same area flash in unison.
    Fire Alarms
    Sync Modules
    Replacement Fire
    Alarm Plates
    Voltage,
    V DC
    Current @
    Voltage
    Light Intensity, cp
    Message
    Ht.
    Wd.
    Dp.
    Knockout
    Trade Size
    Fasteners
    Included
    Includes
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Pair
    Wall Mount/Ceiling Mount
     
    Red Plastic—With LED Bulb
    240.2 amp @ 24V DC15
    30
    75
    110
    150
    185
    Fire8"6 1/2"4 3/8"3/4
    YesFire Alarm Plates
    Outlet Box
    ADA Compliant
    UL 464
    UL 1480
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 728731N1400000008731N150000008733N1700000
     

    Fire Alarm Bells

    Image of Product. Front orientation. Fire Alarms. Fire Alarm Bells.
    When a fire starts, these bells ring loudly to warn you. They’re often mounted near sprinkler systems to help emergency responders locate the water hookup. Connect these bells to your fire detection system, and a signal from your control panel will set them off. They’ll ring as long as the signal is active—their motor vibrates to continuously strike the bell. They help you comply with NFPA 72 standards for fire alarm systems. All bells can be used indoors or outdoors.
    Indoor Boxes—Add an outlet box (sold separately) to mount the bell indoors, or mount to an existing outlet box.
    Outdoor Boxes—Outdoor boxes (sold separately) are lined with gaskets that seal water out and protect the wiring from temperature swings.
    Fire Alarms
    Indoor Boxes
    Outdoor Boxes
    Dia.
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    24V DC
     
    Red Enamel-Coated Aluminum
    6"0.03 amp @ 24V DC92 dBA @ 10 ft.YesUL 464
    ULC-S525
    California Fire Marshal Approved
    FM Approved
    NFPA 7249565T1500000071695K410000059835T34000000
    10"0.03 amp @ 24V DC92 dBA @ 10 ft.YesUL 464
    ULC-S525
    California Fire Marshal Approved
    FM Approved
    NFPA 7249565T160000071695K41000059835T3400000
     
    Guards

    Fire Alarm Horns

    These horns warn you of a fire with loud beeps. Connect them to your fire detection system, and a signal from your control panel will set them off. They help you comply with NFPA 72 standards for fire alarm systems.
    All horns must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a horn that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Horns, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Fire Alarms
    Indoor Boxes
    No. of Programmable
    Tones
    Voltage, V DC
    Current @ Voltage
    Volume (Sound)
    @ Distance
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Wall Mount
     
    Red Plastic
    212
    24
    0.025 amp @ 12V DC
    0.028 amp @ 24V DC
    92 dBA to 99 dBA @ 10 ft.4 3/4"2 3/4"1 1/4"YesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    NFPA 728733N1100000071695K2600000
    812
    24
    0.2 amp @ 12V DC
    0.135 amp @ 24V DC
    92 dBA to 99 dBA @ 10 ft.4 3/4"2 3/4"1 1/4"YesADA Compliant
    UL 464
    UL 1638
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    FM Approved
    NFPA 7259835T130000071695K130000
     
    Ceiling Mount
     
    Red Plastic
    212
    24
    0.025 amp @ 12V DC
    0.028 amp @ 24V DC
    92 dBA to 99 dBA @ 10 ft.6 1/4"1 1/4"YesUL 464
    UL 1638
    UL 1971
    ULC-S525
    ULC-S526
    California Fire Marshal Approved
    NFPA 728733N120000071695K260000
     

    Fire Alarm Speakers

    When a fire breaks out, these speakers broadcast instructions. Connect them to your fire detection system and use your control panel to program the message. These speakers help you comply with NFPA 72 standards for fire alarm systems.
    All speakers must be mounted to an outlet box: use an existing box in your facility, add an outlet box (sold separately), or choose a speaker that includes an outlet box.
    Indoor Only
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Indoor Only, Wall Mount.
    Image of Product. Front orientation. Fire Alarms. Fire Alarm Speakers, Indoor Only, Ceiling Mount.

    Wall Mount

    Ceiling Mount

    Fire Alarms
    Indoor Boxes
    Voltage,
    V DC
    Current @
    Voltage
    Volume (Sound)
    @ Distance
    Message
    Dia.
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Specs. Met
    Certification
    Flammability
    Rating
    Each
    Each
    Wall Mount
     
    Red Plastic
    240.16 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.Fire6 1/4"4 1/2"1 1/2"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728721N1100000071695K1300000
     
    Ceiling Mount
     
    Red Plastic
    240.16 amp @ 24V DC75 dBA to 87 dBA @ 10 ft.Fire6 1/4"1 7/8"YesADA Compliant
    UL 464
    UL 1480
    UL 1971
    ULC-S526
    ULC-S541
    California Fire Marshal Approved
    NFPA 728721N120000071695K130000
     