![]() Fire Extinguisher | ![]() Class B—Liquids and Gases | ![]() Class C—Electrical Equipment | |
![]() Class A—Wood, Paper, Cloth, and Rubber | |||
Douse fires without harming sensitive electronics. These extinguishers have a nonconductive spray that won’t leave powder or residue behind. All are rated to UL Class B and C standards for fire protection. Class A and B ratings also include a number; the higher the number, the greater the firefighting power.
Halotron extinguishers can propel their agent three times farther than carbon dioxide extinguishers, so you can stay at a safe distance from flames. Often used in data centers and server rooms, they can reach fires behind equipment and other obstacles.
Most extinguishers come with a bracket for mounting. Surface brackets hold an extinguisher upright on a wall or other flat surface. Vehicle brackets are more secure than surface brackets—they keep extinguishers from shifting while you’re in motion. Extinguishers that cannot be sold to Canada are restricted due to import regulations.
Fire Extinguishers | Replacement Mounting Brackets | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cap., lbs. | UL Rating | Mounting Location | Charged or Empty | Rechargeable | Cylinder Material | Hardware Material | Dia. | Ht. | Mounting Fasteners Included | Bracket Mounting Hole Dia. (No. of) | Includes | Specifications Met | Cannot Be Sold To | Each | Each | ||
Wet Chemical (Halotron) Fire Extinguishers | |||||||||||||||||
| 2 1/2 | 2-B, C | Vehicle | Charged | Yes | Steel | Aluminum | 4 1/4" | 13 3/8" | No | 7/32" (6) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | __ | 8593N16 | 0000000 | 1031N36 | 000000 |
| 5 1/2 | 5-B, C | Surface | Charged | Yes | Steel | Aluminum | 4 1/4" | 16 3/8" | No | 5/16" (1) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | __ | 8593N17 | 000000 | 1031N29 | 0000 |
| 5 1/2 | 5-B, C | Vehicle | Charged | Yes | Steel | Aluminum | 4 1/4" | 16 3/8" | No | 7/32" (6) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | __ | 8593N18 | 000000 | 1031N37 | 00000 |
| 11 | 1-A, 10-B, C | Surface | Charged | Yes | Steel | Aluminum | 7" | 17 1/2" | No | 5/16" (1) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | Canada | 37015T35 | 00000000 | 1031N34 | 0000 |
| 15 | 2-A, 10-B, C | Surface | Charged | Yes | Steel | Aluminum | 7" | 17 1/2" | No | 5/16" (1) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | Canada | 37015T36 | 00000000 | 1031N34 | 0000 |
Fire Extinguishers for Wood, Fibers, and Rubber
![]() | ![]() Class A—Wood, Paper, Cloth, and Rubber |
![]() Class C—Electrical Equipment |
Filled with water, these extinguishers douse flames without leaving chemical residue behind. They’re rated Class A for use with common combustibles like wood, paper, cloth, and rubber. Built to last, they have brass hardware that resists corrosion and holds up to impacts. Mount them to a wall or other flat surface using the included bracket.
Water extinguishers come empty. Fill them with water and pressurize with a compressed air or nitrogen source that has a 100 psi capacity. Refill them as often as you need.
Water mist extinguishers come charged with a deionized water solution, which they spray in droplets so fine that they won’t conduct electricity. They’re rated Class C for use with electrical equipment. These extinguishers are often used in chemical labs, clean rooms, and other spaces with sensitive equipment that could be damaged by dry chemicals.
Fire Extinguishers | Replacement Mounting Brackets | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Extinguisher Type | Cap., gal. | UL Rating | Charged or Empty | Rechargeable | Cylinder Material | Hardware Material | Dia. | Ht. | Mounting Location | Mounting Fasteners Included | Bracket Mounting Hole Dia. (No. of) | Includes | Specifications Met | Each | Each | ||
| Water | 2 1/2 | 2-A | Empty | Yes | Stainless Steel | Brass | 7" | 24 1/2" | Surface | No | 7/32" (2), 11/32" (1) | 5/16"-32 UNEF Male Schrader Fitting, Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | 6423T3 | 0000000 | 6423T4 | 00000 |
| Water Mist | 2 1/2 | 2-A, C | Charged | Yes | Stainless Steel | Brass | 7" | 28" | Surface | No | 7/32" (2), 11/32" (1) | 5/16"-32 UNEF Male Schrader Fitting, Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 10, UL Listed, C-UL Listed, D.O.T. Compliant 49 CFR 173.309 | 6423T6 | 000000 | 6423T4 | 0000 |
Self-Activating Fire Extinguishers






When flames start to rise, these fire extinguishers automatically put them out. They start spraying if the temperature hits 165° F. Mount them in enclosed spaces where fire is a concern, such as liquid storage rooms. These extinguishers can handle fires involving wood and paper, liquids and gases, and electrical equipment. They can activate once.
Extinguishers | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting Bracket | Mounting Brackets | ||||||||||||||||||
| Capacity, lbs. | Coverage, cu. ft. | Extinguisher Class | Extinguisher Type | Activation Temp., °F | Charged or Empty | Rechargeable | Cylinder Material | Dia. | Ht. | Mounting Location | Fasteners Included | No. of Holes | Hole Dia. | Includes | Specifications Met | Each | Each | ||
Horizontal Mount | |||||||||||||||||||
| 2 1/2 | 120 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 3 3/8" | 14 1/4" | Surface | __ | __ | __ | Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N12 | 0000000 | 1031N36 | 000000 |
| 5 | 180 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 4 1/4" | 17 1/4" | Surface | __ | __ | __ | Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N11 | 000000 | 1031N37 | 00000 |
| 10 | 1,300 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 5 1/8" | 20 7/8" | Surface | __ | __ | __ | Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N13 | 000000 | 1031N38 | 00000 |
| 20 | 2,180 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 7 1/2" | 21 7/8" | Surface | __ | __ | __ | Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N14 | 000000 | 1031N41 | 00000 |
Vertical Mount | |||||||||||||||||||
| 2 1/2 | 120 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 3 3/8" | 15 1/4" | Surface | No | 4 | 1/4" | Mounting Bracket, Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N15 | 000000 | ______ | 00 |
| 5 | 180 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 4 1/4" | 17 1/4" | Surface | No | 4 | 1/4" | Mounting Bracket, Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N16 | 000000 | ______ | 00 |
| 10 | 1,300 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 6" | 17 5/8" | Surface | No | 4 | 1/4" | Mounting Bracket, Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N17 | 000000 | ______ | 00 |
| 20 | 2,180 | A, B, C | Dry Chemical | 165° | Charged | No | Steel | 7 1/2" | 21 7/8" | Surface | No | 4 | 1/4" | Mounting Bracket, Pressure Gauge, Safety Pin | D.O.T. Compliant 49 CFR 173.309, NFPA 10 | 8550N18 | 000000 | ______ | 00 |
Fire Extinguishers for Lithium-Ion Batteries



With a water-based solution that cools burning battery cells and seals out oxygen, these extinguishers keep flames and toxic vapors from spreading. They also meet UL Class A standards for use on wood, cloth, and other common combustibles. These extinguishers discharge a powerful stream rather than a broad spray, so you can stand up to 20 ft. from the source of the flames.
All extinguishers come with a mounting bracket. Add mounting brackets with a strap (sold separately) for a more secure hold.
Fire Extinguishers | Mounting Brackets with 1 Strap | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cap., gal. | UL Rating | Extinguisher Type | Discharge Time, sec. | Charged or Empty | Rechargeable | Dia. | Ht. | Mounting Location | Mounting Fasteners Included | Bracket Mounting Hole Dia. (No. of) | Includes | Specifications Met | Each | Each | ||
| 1/2 | 1-A | Water-Based Agent | 20 | Charged | Yes | 4 1/2" | 16" | Surface | No | 1/4" (2) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 18A | 8740N11 | 0000000 | 1031N91 | 000000 |
| 1 1/2 | 1-A | Water-Based Agent | 30 | Charged | Yes | 7 1/4" | 21 1/2" | Surface | No | 1/4" (2) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 18A | 8740N12 | 000000 | ______ | 00 |
| 2 1/2 | 1-A | Water-Based Agent | 50 | Charged | Yes | 7 1/4" | 24 1/2" | Surface | No | 1/4" (2) | Mounting Bracket, Pressure Gauge, Safety Pin | NFPA 18A | 8740N13 | 000000 | ______ | 00 |