Two-Piece Cover Plates for Fire Sprinkler Heads

Snap these two-piece covers around existing sprinkler heads without having to disassemble or drain the system. Also known as escutcheons, they give your sprinkler heads a clean look.
Adjustable-Depth Two-Piece Cover Plates for Fire Sprinkler Heads


Snap these two-piece covers around existing sprinkler heads without having to disassemble or drain the system. Also known as escutcheons, they give your sprinkler heads a clean look.
Chrome-Plated Steel | White Painted Steel | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Dp. Range | For Sprinkler Head Style | For Pipe Size | For Thread Type | ID | OD | Each | Each | ||
| 1/4"-1 5/8" | Pendent | 1/2 | NPT | 3/4" | 3 3/4" | 6425T5 | 00000 | ______ | 00 |
| 3/4"-1 7/8" | Pendent | 1/2 | NPT | 3/4" | 3 3/4" | 6425T6 | 0000 | ______ | 00 |
| 2"-3" | Pendent | 1/2 | NPT | 3/4" | 3 1/2" | 6425T7 | 0000 | 6425T12 | 00000 |
| 3"-4" | Pendent | 1/2 | NPT | 3/4" | 4 1/2" | 6425T8 | 00000 | 6425T13 | 00000 |
| 3"-5" | Pendent | 1/2 | NPT | 3/4" | 4 1/2" | 6425T11 | 00000 | 6425T14 | 00000 |
Cover Plates for Fire Sprinkler Heads

Install this cover at the same time as a new sprinkler head. Also known as an escutcheon, it gives your sprinkler head a clean look.
| For Sprinkler Head Style | For Pipe Size | For Thread Type | Material | Dp. Range | ID | OD | Each | |
| Pendent | 1/2 | NPT | Chrome-Plated Steel | 2"-3" | 3/4" | 3 1/2" | 6410T4 | 00000 |
Fire Sprinkler Head Guards






Protect sprinkler heads from damage and tampering.
Guards with a water shield are made for upward-facing sprinkler heads. They direct spray downward, so it won’t set off sprinklers higher up. They’re often used for in-rack sprinkler systems.
Hook-on guards are easy to install. Screw-on guards clamp securely onto your sprinkler head with the included lock screw. You can adjust their position up or down on the sprinkler threads.
Each | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| For Pipe Size | For Thread Type | For Sprinkler Head Style | Dia. | Ht. | Material | Color | Includes | 1-9 | 10-Up | |
Guards | ||||||||||
Hook-On Mount | ||||||||||
| 1/2, 3/4 | NPT | Up, Down, Side | 2 1/2" | 3 1/4" | Steel | Red | __ | 6411T11 | 00000 | 00000 |
Screw-On Mount | ||||||||||
| 1/2 | NPT | Up, Down | 4 1/4" | 2" | Steel | Red | Lock Screw | 6411T25 | 0000 | 0000 |
| 3/4 | NPT | Up, Down | 4 1/4" | 2" | Steel | Red | Lock Screw | 6411T36 | 0000 | 0000 |
Guards with Water Shield | ||||||||||
Hook-On Mount | ||||||||||
| 1/2, 3/4 | NPT | Up | 2 1/2" | 3 1/4" | Steel | Red | __ | 6411T12 | 0000 | 0000 |
Rack-Mount Fire Sprinkler Head Guards




Keep forklifts and other vehicles from damaging sprinklers in your rack system. These guards are bright yellow, so they’re easy to spot from a distance. Mount them directly to rack beams.
Concealed Fire Sprinkler Heads

An inconspicuous cover plate provides a clean look for sprinkler heads. When the plate's temperature rating is reached, it falls away to expose the sprinkler head. The head itself has a liquid-filled glass bulb that bursts at the rated temperature to trigger the sprinkler. Install using required wrenches (sold separately).
1/2 NPT Male Connection | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature | Cover Plates | Required Wrenches | ||||||||||
| Plate Temperature Rating, ° F | Plate Color | Rating, °F | Color Code | Flow Rate | Specifications Met | Sprinkler Head Style | Each | Each | Each | |||
| 139° | Chrome | 155° | Red | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 6496T311 | 000000 | 6496T211 | 000000 | 6496T79 | 0000000 |
| 139° | White | 155° | Red | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 6496T312 | 00000 | 6496T212 | 00000 | 6496T79 | 000000 |
| 165° | Chrome | 200° | Green | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 6496T321 | 00000 | 6496T221 | 00000 | 6496T79 | 000000 |
| 165° | White | 200° | Green | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 6496T322 | 00000 | 6496T222 | 00000 | 6496T79 | 000000 |
Recessed Fire Sprinkler Heads


Use these sprinkler heads for low-profile fire safety. Install using required wrenches (sold separately).
Glass-bulb sprinkler heads are triggered when the liquid-filled bulb bursts at the rated temperature.
Fusible-link sprinkler heads are triggered by a soft metal alloy that melts at the rated temperature.
1/2 NPT Male Connection | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature | Cover Plates | Required Wrenches | |||||||||||
| Rating, °F | Color Code | Flow Rate | Max. Pressure, psi | Recess Dia. | Recess Dp. | Material | Specifications Met | Each | Each | Each | |||
Glass Bulb | |||||||||||||
| 155° | Red | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 63945T81 | 000000 | 63945T91 | 00000 | 64575T98 | 0000000 |
| 175° | Yellow | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 63945T83 | 00000 | 63945T91 | 0000 | 64575T98 | 000000 |
| 200° | Green | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 63945T85 | 00000 | 63945T91 | 0000 | 64575T98 | 000000 |
Fusible Link | |||||||||||||
| 165° | __ | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 63945T94 | 00000 | 63945T91 | 0000 | 64575T88 | 000000 |
| 212° | White | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 63945T95 | 00000 | 63945T91 | 0000 | 64575T88 | 000000 |