McMaster-Carr logo
    Filter by
    DFARS Specialty Metals
    Specifications Met
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Fire Safety Rating
    Insert Type
    Outlet Box Designation
    Industrial Info Compare
    Number of Outlets
    For Number of Toggle Switches
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    22 Products

    Fire-Stop Putty

    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Putty.
    Image of Product. Pad. Front orientation. Fire Stops. Fire-Stop Putty, Pads.

    Pad

    Image of Product. Stick. Front orientation. Fire Stops. Fire-Stop Putty, Sticks.

    Stick

    Hand-mold this putty into small openings in fire-resistant walls and floors.
    Pads—Putty pads are often used to seal the area around electrical boxes. Mold them onto the sides of the box before installing it in a wall or floor.
    Expandable—Often used to seal the area around PVC pipes or cables, it expands when heated to fill the gaps left if your equipment melts.
    Flammability Rating—This putty is tested to ASTM and UL standards to stop the spread of smoke and flames.
    Each
    Package
    Form
    Lg.
    Wd.
    Thk.
    Color
    Application
    Temp., ° F
    Fire-Stop
    Application
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Performance
    Each
    Pkg.
    Qty.
    Pkg.
    Pad7"7"1/8"Red40 to 120Through Penetration3 hr.ASTM E84 10/125 for Flame and Smoke, ASTM E119, UL 263, UL 723 10/125 for Flame and Smoke, UL 1479ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable9340K2200000209340K240000000
    Stick10"1 1/2"1 1/2"Red40 to 120Through Penetration3 hr.ASTM E84 10/125 for Flame and Smoke, ASTM E119, UL 263, UL 723 10/125 for Flame and Smoke, UL 1479ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable9340K2300000129340K25000000
     

    Fire-Stop Electrical Box Inserts

    Seal electrical boxes to maintain fire-resistant walls. These inserts mount inside electrical boxes to block the spread of smoke and flames. They fit common box sizes.
    Gaskets
    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets, For NEMA Outlets.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets, For GFCI Outlets.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets, For Toggle Switches.

    For

    NEMA

    Outlets

    For

    GFCI

    Outlets

    For

    Toggle

    Switches

    Use gaskets when cable or switches have already been installed. They sit just inside your cover plate.
    Expandable—When heated, they expand to seal gaps, such as those left by melted wire.
    Each
    Package
    Outlet Box
    Designation
    For No.
    of Outlets
    For No. of Toggle
    Switches
    Lg.
    Wd.
    Thk.
    Application
    Temp., ° F
    Fire-Stop
    Application
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Performance
    Each
    Pkg.
    Qty.
    Pkg.
    For NEMA Outlets
    1 Gang
    25"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N11100000508505N1120000000
    2 Gang
    45"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N1130000508505N114000000
     
    For GFCI Outlets
    1 Gang
    15"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N1150000508505N116000000
    2 Gang
    25"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N1170000508505N118000000
     
    For Toggle Switches
    1 Gang
    15"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N1190000508505N121000000
    2 Gang
    25"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N1220000508505N123000000
     
    Pads
    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Pads.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Pads.
    Use pads before cable is installed. The adhesive side sticks to the back wall of your electrical box. They can be used only with metallic boxes.
    Expandable—When heated, they expand to seal gaps, such as those left by melted wire.
    Each
    Package
    Outlet Box
    Designation
    Lg.
    Wd.
    Thk.
    Mount Type
    Application
    Temp., ° F
    Fire-Stop
    Application
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Performance
    Each
    Pkg.
    Qty.
    Pkg.
    1 Gang
    1 13/16"2 13/16"1/4"Adhesive Back40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N12400000508505N1250000000
    2 Gang
    3 3/4"3 11/16"1/4"Adhesive Back40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N1260000508505N127000000
    2 Gang
    4 3/8"4 3/8"1/4"Adhesive Back40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable8505N12800000508505N129000000
     
    back to top